$ 348.70 – $ 362.78
Main | ||||
Part Number | LC1D245E7C | LC1D245F5C | LC1D245F7C | LC1D245M5C |
Product Series | TeSys Deca | TeSys Deca | TeSys Deca | TeSys Deca |
Product Series | TeSys Deca | TeSys Deca | TeSys Deca | TeSys Deca |
product type | Contactor | Contactor | Contactor | Contactor |
product short name | LC1D | LC1D | LC1D | LC1D |
Application field of contactor | Applied to AC loads with power factor greater than or equal to 0.95 Applied to non-inductive or slightly inductive loads, resistance furnaces |
Applied to non-inductive or micro-inductive loads, and resistance furnaces to AC loads with a power factor greater than or equal to 0.95 |
Applied to AC loads with power factor greater than or equal to 0.95 Applied to non-inductive or slightly inductive loads, resistance furnaces |
Applied to AC loads with power factor greater than or equal to 0.95 Applied to non-inductive or slightly inductive loads, resistance furnaces |
use category | AC-1AC -3 |
AC-1AC -3 |
AC-3AC -1 |
AC-1AC -3 |
number of poles | 3P | 3P | 3P | 3P |
Rated working voltage [Ue] | Power circuit: <= 1000 V AC 25…400 Hz Power circuit: <= 460 V DC |
Power circuit: <= 1000 V AC 25…400 Hz Power circuit: <= 460 V DC |
Power circuit: <= 1000 V AC 25…400 Hz Power circuit: <= 460 V DC |
Power circuit: <= 1000 V AC 25…400 Hz Power circuit: <= 460 V DC |
Rated operating current [Ie] | 315 A 40 °C) at <= 440 V AC AC-1 for power circuits 245 A 40 °C) at <= 440 V AC AC-3 for power circuits |
315 A 40 °C) at <= 440 V AC AC-1 for power circuits 245 A 40 °C) at <= 440 V AC AC-3 for power circuits |
315 A 40 °C) at <= 440 V AC AC-1 for power circuits 245 A 40 °C) at <= 440 V AC AC-3 for power circuits |
315 A 40 °C) at <= 440 V AC AC-1 for power circuits 245 A 40 °C) at <= 440 V AC AC-3 for power circuits |
[Uc] control circuit voltage | 48 V AC 50/60 Hz | 110V AC 50Hz | 110V AC 50/60Hz | 230V AC 50Hz |
Additional information | ||||
Motor power (kW) | 75 kW at 220/240 V AC 50/60 Hz (AC-3) 132 kW at 380/400 V AC 50/60 Hz (AC-3) 132 kW at 415 V AC 50/60 Hz (AC-3) 132 kW at 440 V AC 50/60 Hz (AC-3) 160 kW at 500 V AC 50/60 Hz (AC-3) 160 kW at 660/690 V AC 50 /60 Hz (AC-3) 147 kW at 1000 V AC 50/60 Hz (AC-3) |
75 kW at 220/240 V AC 50/60 Hz (AC-3) 132 kW at 380/400 V AC 50/60 Hz (AC-3) 132 kW at 415 V AC 50/60 Hz (AC-3) 132 kW at 440 V AC 50/60 Hz (AC-3) 160 kW at 500 V AC 50/60 Hz (AC-3) 160 kW at 660/690 V AC 50 /60 Hz (AC-3) 147 kW at 1000 V AC 50/60 Hz (AC-3) |
75 kW at 220/240 V AC 50/60 Hz (AC-3) 132 kW at 380/400 V AC 50/60 Hz (AC-3) 132 kW at 415 V AC 50/60 Hz (AC-3) 132 kW at 440 V AC 50/60 Hz (AC-3) 160 kW at 500 V AC 50/60 Hz (AC-3) 160 kW at 660/690 V AC 50 /60 Hz (AC-3) 147 kW at 1000 V AC 50/60 Hz (AC-3) |
75 kW at 220/240 V AC 50/60 Hz (AC-3) 132 kW at 380/400 V AC 50/60 Hz (AC-3) 132 kW at 415 V AC 50/60 Hz (AC-3) 132 kW at 440 V AC 50/60 Hz (AC-3) 160 kW at 500 V AC 50/60 Hz (AC-3) 160 kW at 660/690 V AC 50 /60 Hz (AC-3) 147 kW at 1000 V AC 50/60 Hz (AC-3) |
model | LC1D | LC1D | LC1D | LC1D |
Loop contact type | 3 NO | 3 NO | 3 NO | 3 NO |
protection cap | None | None | None | None |
Conventional thermal current [Ith] | 315 A at <40 °C for power circuits | 315 A at <40 °C for power circuits | 315 A at <40 °C for power circuits | 315 A at <40 °C for power circuits |
Rated short-time withstand current [Icw] | 1800 A at <40 °C – 10 s for power circuit 1000 A at <40 °C – 30 s for power circuit 850 A at <40 °C – 1 min for power circuit 560 A at <40 °C – 3 minutes for power circuit 440 A at <40 °C – 10 minutes for power circuit |
1800 A at <40 °C – 10 s for power circuit 1000 A at <40 °C – 30 s for power circuit 850 A at <40 °C – 1 min for power circuit 560 A at <40 °C – 3 minutes for power circuit 440 A at <40 °C – 10 minutes for power circuit |
1800 A at <40 °C – 10 s for power circuit 1000 A at <40 °C – 30 s for power circuit 850 A at <40 °C – 1 min for power circuit 560 A at <40 °C – 3 minutes for power circuit 440 A at <40 °C – 10 minutes for power circuit |
1800 A at <40 °C – 10 s for power circuit 1000 A at <40 °C – 30 s for power circuit 850 A at <40 °C – 1 min for power circuit 560 A at <40 °C – 3 minutes for power circuit 440 A at <40 °C – 10 minutes for power circuit |
Fuses for use with relays | 315 A gG at <= 440 V for power circuits 250 A aM at <= 440 V for power circuits |
315 A gG at <= 440 V for power circuits 250 A aM at <= 440 V for power circuits |
315 A gG at <= 440 V for power circuits 250 A aM at <= 440 V for power circuits |
315 A gG at <= 440 V for power circuits 250 A aM at <= 440 V for power circuits |
average impedance | 0.32 mΩ – Ith 315 A 50 Hz for power circuits | 0.32 mΩ – Ith 315 A 50 Hz for power circuits | 0.32 mΩ – Ith 315 A 50 Hz for power circuits | 0.32 mΩ – Ith 315 A 50 Hz for power circuits |
Rated insulation voltage [Ui] | Power circuit: 1000 V conforming to IEC 60947-4-1 | Power circuit: 1000 V conforming to IEC 60947-4-1 | Power circuit: 1000 V conforming to IEC 60947-4-1 | Power circuit: 1000 V conforming to IEC 60947-4-1 |
Overvoltage category | III | III | III | III |
pollution level | 3 | 3 | 3 | 3 |
Rated impulse withstand voltage [Uimp] | 8 kV according to IEC 60947 | 8 kV according to IEC 60947 | 8 kV according to IEC 60947 | 8 kV according to IEC 60947 |
Mechanical life | 8 Mcycles | 8 Mcycles | 8 Mcycles | 8 Mcycles |
Electrical life | 0.45 Mcycles 315 A AC-1 Ue <= 440 V 1 Mcycles 200 A AC-3 Ue <= 440 V 1 Mcycles 129 A AC-3 Ue 660/690 V |
0.45 Mcycles 315 A AC-1 Ue <= 440 V 1 Mcycles 200 A AC-3 Ue <= 440 V 1 Mcycles 129 A AC-3 Ue 660/690 V |
0.45 Mcycles 315 A AC-1 Ue <= 440 V 1 Mcycles 200 A AC-3 Ue <= 440 V 1 Mcycles 129 A AC-3 Ue 660/690 V |
0.45 Mcycles 315 A AC-1 Ue <= 440 V 1 Mcycles 200 A AC-3 Ue <= 440 V 1 Mcycles 129 A AC-3 Ue 660/690 V |
Control loop characteristics | AC at 50/60 Hz | AC at 50 Hz | AC at 50/60 Hz | AC at 50 Hz |
Control voltage limit | 0.35…0.55 Uc -5…55 °C release 50/60 Hz 0.85…1.15 Uc -5…55 °C run 50/60 Hz |
0.85…1.15 Uc -5…55 °C operating 50 Hz 0.35…0.55 Uc -5…55 °C releasing 50 Hz |
0.35…0.55 Uc -5…55 °C release 50/60 Hz 0.85…1.15 Uc -5…55 °C run 50/60 Hz |
0.85…1.15 Uc -5…55 °C operating 50 Hz 0.35…0.55 Uc -5…55 °C releasing 50 Hz |
(~50Hz pickup) power consumption (VA) | 805 VA 50 Hz 0.3 20 °C) 970 VA 60 Hz 0.3 20 °C) |
805VA 50Hz (0.320°C) | 805 VA 50 Hz 0.3 20 °C) 970 VA 60 Hz 0.3 20 °C) |
805VA 50Hz (0.320°C) |
(~50Hz hold) power consumption (VA) | 55 VA 50 Hz 0.3 20 °C) 66 VA 60 Hz 0.3 20 °C) |
55VA 50Hz (0.320°C) | 55 VA 50 Hz 0.3 20 °C) 66 VA 60 Hz 0.3 20 °C) |
55VA 50Hz (0.320°C) |
heat dissipation | 18…24W | 18…24W | 18…24W | 18…24W |
action time | 20…35 ms closed 7…15 ms open |
20…35 ms closed 7…15 ms open |
20…35 ms closed 7…15 ms open |
20…35 ms closed 7…15 ms open |
operating frequency | 2400 cycles/h at <55 °C | 2400 cycles/h at <55 °C | 2400 cycles/h at <55 °C | 2400 cycles/h at <55 °C |
Wiring capacity | Control circuit: Bolt fastening Cable selection: Flexible wire without wire terminal Control circuit: Bolt fastening Cable selection: Flexible wire with wire terminal Power circuit: Cable with lug Cable selection: Stranded wire with wire Wire Terminals Power Circuit: Terminal Connector Cable Selection: Stranded Wire with Wire Terminals Control Circuit: Bolt Fastened Cable Selection: Solid Wire Without Wire Terminals Power Circuit: Busbar Terminals Cable Selection: Hard Wire Cross-section of busbars without wire terminals: 32 x 4 mm |
Control circuit: Bolt fastening Cable selection: Flexible wire without wire terminal Control circuit: Bolt fastening Cable selection: Flexible wire with wire terminal Power circuit: Cable with lug Cable selection: Stranded wire with wire Wire Terminals Power Circuit: Terminal Connector Cable Selection: Stranded Wire with Wire Terminals Control Circuit: Bolt Fastened Cable Selection: Solid Wire Without Wire Terminals Power Circuit: Busbar Terminals Cable Selection: Hard Wire Cross-section of busbars without wire terminals: 32 x 4 mm |
Control circuit: Bolt fastening Cable selection: Flexible wire without wire terminal Control circuit: Bolt fastening Cable selection: Flexible wire with wire terminal Power circuit: Cable with lug Cable selection: Stranded wire with wire Wire Terminals Power Circuit: Terminal Connector Cable Selection: Stranded Wire with Wire Terminals Control Circuit: Bolt Fastened Cable Selection: Solid Wire Without Wire Terminals Power Circuit: Busbar Terminals Cable Selection: Hard Wire Cross-section of busbars without wire terminals: 32 x 4 mm |
Control circuit: Bolt fastening Cable selection: Flexible wire without wire terminal Control circuit: Bolt fastening Cable selection: Flexible wire with wire terminal Power circuit: Cable with lug Cable selection: Stranded wire with wire Wire Terminals Power Circuit: Terminal Connector Cable Selection: Stranded Wire with Wire Terminals Control Circuit: Bolt Fastened Cable Selection: Solid Wire Without Wire Terminals Power Circuit: Busbar Terminals Cable Selection: Hard Wire Cross-section of busbars without wire terminals: 32 x 4 mm |
Tightening torque |
Control circuit: 1.2 Nm Power circuit via bolt fastening : 35 Nm Power circuit via busbar terminals: 35 Nm via cable connector |
Control circuit: 1.2 Nm Power circuit via bolt fastening : 35 Nm Power circuit via busbar terminals: 35 Nm via cable connector |
Control circuit: 1.2 Nm Power circuit via bolt fastening : 35 Nm Power circuit via busbar terminals: 35 Nm via cable connector |
Control circuit: 1.2 Nm Power circuit via bolt fastening : 35 Nm Power circuit via busbar terminals: 35 Nm via cable connector |
Auxiliary contact type | Does not contain | Does not contain | Does not contain | Does not contain |
installation method | DIN rail installation base plate installation |
Chassis mounting rail installation |
Chassis mounting rail installation |
DIN rail installation base plate installation |
environment | ||||
standard | GB 14048.4 IEC 60947-4-1 |
IEC 60947-4-1 GB 14048.4 |
GB 14048.4 IEC 60947-4-1 |
GB 14048.4 IEC 60947-4-1 |
certified product | CCC CE |
CCC CE |
CCC CE |
CCC CE |
IP protection class | IP20 front panel with LA9F conforming to IEC 60529 | IP20 front panel with LA9F conforming to IEC 60529 | IP20 front panel with LA9F conforming to IEC 60529 | IP20 front panel with LA9F conforming to IEC 60529 |
Protective measures | TH conforms to IEC 60068-2-30 | TH conforms to IEC 60068-2-30 | TH conforms to IEC 60068-2-30 | TH conforms to IEC 60068-2-30 |
ambient air temperature | -40…60 °C operation 60…70 °C with derating -60…80 °C storage |
-40…60 °C operation 60…70 °C with derating -60…80 °C storage |
-40…60 °C operation 60…70 °C with derating -60…80 °C storage |
-40…60 °C operation 60…70 °C with derating -60…80 °C storage |
working altitude | 3000 m None | 3000 m None | 3000 m None | 3000 m None |
Shock and vibration resistance | Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance for 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27 Shock resistance with contacts closed (5 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance 11 ms contact opening (7 gn) conforming to IEC 60068-2-27 |
Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance for 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27 Shock resistance with contacts closed (5 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance 11 ms contact opening (7 gn) conforming to IEC 60068-2-27 |
Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance for 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27 Shock resistance with contacts closed (5 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance 11 ms contact opening (7 gn) conforming to IEC 60068-2-27 |
Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance for 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27 Shock resistance with contacts closed (5 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance 11 ms contact opening (7 gn) conforming to IEC 60068-2-27 |
high | 197 mm | 197 mm | 197 mm | 197 mm |
width | 168.5mm | 168.5mm | 168.5mm | 168.5mm |
depth | 181 mm | 181 mm | 181 mm | 181 mm |
Product Weight | 5.3kg | 5.3kg | 5.3kg | 5.3kg |
packaging unit | ||||
Unit Type of Package 1 | PCE | PCE | PCE | PCE |
Number of Units in Package 1 | 1 | 1 | 1 | 1 |
Package 1 Height | 21.0cm | 21.0cm | 21.0cm | 22.0cm |
Package 1 Width | 22.0cm | 22.0cm | 22.0cm | 21.7cm |
Package 1 Length | 23.5cm | 23.5cm | 23.5cm | 22.9 cm |
Package 1 Weight | 5401.0g | 5401.0g | 5401.0g | 5.157 kg |
Unit Type of Package 2 | P06 | P06 | P06 | PAL |
Number of Units in Package 2 | 12 | 12 | 12 | 12 |
Package 2 Height | 57.0cm | 57.0cm | 57.0cm | 42.0cm |
Package 2 Width | 60.0cm | 60.0cm | 60.0cm | 60.0cm |
Package 2 Length | 80.0cm | 80.0cm | 80.0cm | 80.0cm |
Package 2 Weight | 74.812kg | 74.812kg | 74.812kg | 66.684kg |
contract warranty | ||||
Warranty | 18 months | 18 months | 18 months | 18 months |
Main | |||
Part Number | LC1D245M7C | LC1D245Q5C | LC1D245Q7C |
Product Series | TeSys Deca | TeSys Deca | TeSys Deca |
Product Series | TeSys Deca | TeSys Deca | TeSys Deca |
product type | Contactor | Contactor | Contactor |
product short name | LC1D | LC1D | LC1D |
Application field of contactor | Applied to non-inductive or micro-inductive loads, and resistance furnaces to AC loads with a power factor greater than or equal to 0.95 |
Applied to AC loads with power factor greater than or equal to 0.95 Applied to non-inductive or slightly inductive loads, resistance furnaces |
Applied to non-inductive or micro-inductive loads, and resistance furnaces to AC loads with a power factor greater than or equal to 0.95 |
use category | AC-1AC -3 |
AC-3AC -1 |
AC-1AC -3 |
number of poles | 3P | 3P | 3P |
Rated working voltage [Ue] | Power circuit: <= 1000 V AC 25…400 Hz Power circuit: <= 460 V DC |
Power circuit: <= 1000 V AC 25…400 Hz Power circuit: <= 460 V DC |
Power circuit: <= 1000 V AC 25…400 Hz Power circuit: <= 460 V DC |
Rated operating current [Ie] | 315 A 40 °C) at <= 440 V AC AC-1 for power circuits 245 A 40 °C) at <= 440 V AC AC-3 for power circuits |
315 A 40 °C) at <= 440 V AC AC-1 for power circuits 245 A 40 °C) at <= 440 V AC AC-3 for power circuits |
315 A 40 °C) at <= 440 V AC AC-1 for power circuits 245 A 40 °C) at <= 440 V AC AC-3 for power circuits |
[Uc] control circuit voltage | 230V AC 50/60Hz | 380V AC 50Hz | 380 V AC 50/60 Hz |
Additional information | |||
Motor power (kW) | 75 kW at 220/240 V AC 50/60 Hz (AC-3) 132 kW at 380/400 V AC 50/60 Hz (AC-3) 132 kW at 415 V AC 50/60 Hz (AC-3) 132 kW at 440 V AC 50/60 Hz (AC-3) 160 kW at 500 V AC 50/60 Hz (AC-3) 160 kW at 660/690 V AC 50 /60 Hz (AC-3) 147 kW at 1000 V AC 50/60 Hz (AC-3) |
75 kW at 220/240 V AC 50/60 Hz (AC-3) 132 kW at 380/400 V AC 50/60 Hz (AC-3) 132 kW at 415 V AC 50/60 Hz (AC-3) 132 kW at 440 V AC 50/60 Hz (AC-3) 160 kW at 500 V AC 50/60 Hz (AC-3) 160 kW at 660/690 V AC 50 /60 Hz (AC-3) 147 kW at 1000 V AC 50/60 Hz (AC-3) |
75 kW at 220/240 V AC 50/60 Hz (AC-3) 132 kW at 380/400 V AC 50/60 Hz (AC-3) 132 kW at 415 V AC 50/60 Hz (AC-3) 132 kW at 440 V AC 50/60 Hz (AC-3) 160 kW at 500 V AC 50/60 Hz (AC-3) 160 kW at 660/690 V AC 50 /60 Hz (AC-3) 147 kW at 1000 V AC 50/60 Hz (AC-3) |
model | LC1D | LC1D | LC1D |
Loop contact type | 3 NO | 3 NO | 3 NO |
protection cap | None | None | None |
Conventional thermal current [Ith] | 315 A at <40 °C for power circuits | 315 A at <40 °C for power circuits | 315 A at <40 °C for power circuits |
Rated short-time withstand current [Icw] | 1800 A at <40 °C – 10 s for power circuit 1000 A at <40 °C – 30 s for power circuit 850 A at <40 °C – 1 min for power circuit 560 A at <40 °C – 3 minutes for power circuit 440 A at <40 °C – 10 minutes for power circuit |
1800 A at <40 °C – 10 s for power circuit 1000 A at <40 °C – 30 s for power circuit 850 A at <40 °C – 1 min for power circuit 560 A at <40 °C – 3 minutes for power circuit 440 A at <40 °C – 10 minutes for power circuit |
1800 A at <40 °C – 10 s for power circuit 1000 A at <40 °C – 30 s for power circuit 850 A at <40 °C – 1 min for power circuit 560 A at <40 °C – 3 minutes for power circuit 440 A at <40 °C – 10 minutes for power circuit |
Fuses for use with relays | 315 A gG at <= 440 V for power circuits 250 A aM at <= 440 V for power circuits |
315 A gG at <= 440 V for power circuits 250 A aM at <= 440 V for power circuits |
315 A gG at <= 440 V for power circuits 250 A aM at <= 440 V for power circuits |
average impedance | 0.32 mΩ – Ith 315 A 50 Hz for power circuits | 0.32 mΩ – Ith 315 A 50 Hz for power circuits | 0.32 mΩ – Ith 315 A 50 Hz for power circuits |
Rated insulation voltage [Ui] | Power circuit: 1000 V conforming to IEC 60947-4-1 | Power circuit: 1000 V conforming to IEC 60947-4-1 | Power circuit: 1000 V conforming to IEC 60947-4-1 |
Overvoltage category | III | III | III |
pollution level | 3 | 3 | 3 |
Rated impulse withstand voltage [Uimp] | 8 kV according to IEC 60947 | 8 kV according to IEC 60947 | 8 kV according to IEC 60947 |
Mechanical life | 8 Mcycles | 8 Mcycles | 8 Mcycles |
Electrical life | 0.45 Mcycles 315 A AC-1 Ue <= 440 V 1 Mcycles 200 A AC-3 Ue <= 440 V 1 Mcycles 129 A AC-3 Ue 660/690 V |
0.45 Mcycles 315 A AC-1 Ue <= 440 V 1 Mcycles 200 A AC-3 Ue <= 440 V 1 Mcycles 129 A AC-3 Ue 660/690 V |
0.45 Mcycles 315 A AC-1 Ue <= 440 V 1 Mcycles 200 A AC-3 Ue <= 440 V 1 Mcycles 129 A AC-3 Ue 660/690 V |
Control loop characteristics | AC at 50/60 Hz | AC at 50 Hz | AC at 50/60 Hz |
Control voltage limit | 0.35…0.55 Uc -5…55 °C release 50/60 Hz 0.85…1.15 Uc -5…55 °C run 50/60 Hz |
0.85…1.15 Uc -5…55 °C operating 50 Hz 0.35…0.55 Uc -5…55 °C releasing 50 Hz |
0.35…0.55 Uc -5…55 °C release 50/60 Hz 0.85…1.15 Uc -5…55 °C run 50/60 Hz |
(~50Hz pickup) power consumption (VA) | 805 VA 50 Hz 0.3 20 °C) 970 VA 60 Hz 0.3 20 °C) |
805VA 50Hz (0.320°C) | 805 VA 50 Hz 0.3 20 °C) 970 VA 60 Hz 0.3 20 °C) |
(~50Hz hold) power consumption (VA) | 55 VA 50 Hz 0.3 20 °C) 66 VA 60 Hz 0.3 20 °C) |
55VA 50Hz (0.320°C) | 55 VA 50 Hz 0.3 20 °C) 66 VA 60 Hz 0.3 20 °C) |
heat dissipation | 18…24W | 18…24W | 18…24W |
action time | 20…35 ms closed 7…15 ms open |
20…35 ms closed 7…15 ms open |
20…35 ms closed 7…15 ms open |
operating frequency | 2400 cycles/h at <55 °C | 2400 cycles/h at <55 °C | 2400 cycles/h at <55 °C |
Wiring capacity | Control circuit: Bolt fastening Cable selection: Flexible wire without wire terminal Control circuit: Bolt fastening Cable selection: Flexible wire with wire terminal Power circuit: Cable with lug Cable selection: Stranded wire with wire Wire Terminals Power Circuit: Terminal Connector Cable Selection: Stranded Wire with Wire Terminals Control Circuit: Bolt Fastened Cable Selection: Solid Wire Without Wire Terminals Power Circuit: Busbar Terminals Cable Selection: Hard Wire Cross-section of busbars without wire terminals: 32 x 4 mm |
Control circuit: Bolt fastening Cable selection: Flexible wire without wire terminal Control circuit: Bolt fastening Cable selection: Flexible wire with wire terminal Power circuit: Cable with lug Cable selection: Stranded wire with wire Wire Terminals Power Circuit: Terminal Connector Cable Selection: Stranded Wire with Wire Terminals Control Circuit: Bolt Fastened Cable Selection: Solid Wire Without Wire Terminals Power Circuit: Busbar Terminals Cable Selection: Hard Wire Cross-section of busbars without wire terminals: 32 x 4 mm |
Control circuit: Bolt fastening Cable selection: Flexible wire without wire terminal Control circuit: Bolt fastening Cable selection: Flexible wire with wire terminal Power circuit: Cable with lug Cable selection: Stranded wire with wire Wire Terminals Power Circuit: Terminal Connector Cable Selection: Stranded Wire with Wire Terminals Control Circuit: Bolt Fastened Cable Selection: Solid Wire Without Wire Terminals Power Circuit: Busbar Terminals Cable Selection: Hard Wire Cross-section of busbars without wire terminals: 32 x 4 mm |
Tightening torque |
Control circuit: 1.2 Nm Power circuit via bolt fastening : 35 Nm Power circuit via busbar terminals: 35 Nm via cable connector |
Control circuit: 1.2 Nm Power circuit via bolt fastening : 35 Nm Power circuit via busbar terminals: 35 Nm via cable connector |
Control circuit: 1.2 Nm Power circuit via bolt fastening : 35 Nm Power circuit via busbar terminals: 35 Nm via cable connector |
Auxiliary contact type | Does not contain | Does not contain | Does not contain |
installation method | Chassis mounting rail installation |
DIN rail installation base plate installation |
DIN rail installation base plate installation |
environment | |||
standard | IEC 60947-4-1 GB 14048.4 |
GB 14048.4 IEC 60947-4-1 |
GB 14048.4 IEC 60947-4-1 |
certified product | CCC CE |
CCC CE |
CCC CE |
IP protection class | IP20 front panel with LA9F conforming to IEC 60529 | IP20 front panel with LA9F conforming to IEC 60529 | IP20 front panel with LA9F conforming to IEC 60529 |
Protective measures | TH conforms to IEC 60068-2-30 | TH conforms to IEC 60068-2-30 | TH conforms to IEC 60068-2-30 |
ambient air temperature | -40…60 °C operation 60…70 °C with derating -60…80 °C storage |
-40…60 °C operation 60…70 °C with derating -60…80 °C storage |
-40…60 °C operation 60…70 °C with derating -60…80 °C storage |
working altitude | 3000 m None | 3000 m None | 3000 m None |
Shock and vibration resistance | Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance for 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27 Shock resistance with contacts closed (5 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance 11 ms contact opening (7 gn) conforming to IEC 60068-2-27 |
Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance for 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27 Shock resistance with contacts closed (5 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance 11 ms contact opening (7 gn) conforming to IEC 60068-2-27 |
Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance for 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27 Shock resistance with contacts closed (5 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance 11 ms contact opening (7 gn) conforming to IEC 60068-2-27 |
high | 197 mm | 197 mm | 197 mm |
width | 168.5mm | 168.5mm | 168.5 mm |
depth | 181 mm | 181 mm | 181 mm |
Product Weight | 5.3kg | 5.3kg | 5.3 kg |
packaging unit | |||
Unit Type of Package 1 | PCE | PCE | PCE |
Number of Units in Package 1 | 1 | 1 | 1 |
Package 1 Height | 22.0cm | 21.595 cm | 21.73 cm |
Package 1 Width | 21.5cm | 23.859 cm | 22.6 cm |
Package 1 Length | 23.1 cm | 22.462 cm | 23.641 cm |
Package 1 Weight | 5.168 kg | 5.25 kg | 5.281kg |
Unit Type of Package 2 | PAL | PAL | PAL |
Number of Units in Package 2 | 12 | 12 | 12 |
Package 2 Height | 42.0cm | 42.0cm | 42.0cm |
Package 2 Width | 60.0cm | 60.0cm | 60.0cm |
Package 2 Length | 80.0cm | 80.0cm | 80.0cm |
Package 2 Weight | 66.84kg | 66.0kg | 66.0kg |
contract warranty | |||
Warranty | 18 months | 18 months | 18 months |
Weight | N/A |
---|---|
Dimensions | N/A |
INOSAKI Limited
RM B 5/F Gaylord Comm,
Bldg 114-118 Lockhart Rd.
Hong Kong
INOSAKI Sdn. Bhd.
2-1-9, Ground Floor, One Square, Tingkat Mahsuri 1,
11900 Bayan Lepas, Penan
INOSAKI Pte. Ltd.
101 Upper Cross Street,
No. 06-17, People’s Park Centre,