W23-2 – WL23-2P2430 Photoelectric Sensors – Compact Photoelectric Sensors – SICK Sensor

USD $ 103.50

Out of stock

SKU: N/A

SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.

Part Number: 1027785
Photoelectric Sensor Model: WL23-2P2430
OEM Spec Ref 

Features

Sensor/ detection principlePhotoelectric retro-reflective sensor, Dual lens
Dimensions (W x H x D)24.6 mm x 80.6 mm x 54 mm
Housing design (light emission)Rectangular
Sensing range max.0.1 m … 10 m 1)
Sensing range0.3 m … 7 m 1)
Type of lightVisible red light
Light sourceLED 2)
Light spot size (distance)Ø 45 mm (2.7 m)
Angle of dispersion1.5°
Wave length660 nm
AdjustmentNone
  • 1) Reflector PL80A.
  • 2) Average service life: 100,000 h at TU = +25 °C.

 

Mechanics/electronics

Supply voltage10 V DC … 30 V DC 1)
Ripple< 5 Vpp 2)
Switching outputPNP
Output functionComplementary
Switching modeLight/dark switching
Signal voltage PNP HIGH/LOWApprox. VS – 2.5 V / 0 V
Output current Imax.≤ 100 mA
Response time≤ 2.5 ms 3)
Switching frequency200 Hz 4)
Connection typeMale connector M12, 4-pin
Circuit protection

5)

6)

7)

Protection classII 8)
Weight100 g
Polarisation filter
Housing materialPlastic, ABS
Optics materialPlastic, PMMA
Enclosure ratingIP67
Ambient operating temperature–25 °C … +60 °C
Ambient storage temperature–40 °C … +70 °C
UL File No.NRKH.E181493 & NRKH7.E181493
  • 1) Limit values when operated in short-circuit protected network: max. 8 A.
  • 2) May not exceed or fall below Uv tolerances.
  • 3) Signal transit time with resistive load.
  • 4) With light/dark ratio 1:1.
  • 5) A = VS connections reverse-polarity protected.
  • 6) C = interference suppression.
  • 7) D = outputs overcurrent and short-circuit protected.
  • 8) Reference voltage: 50 V DC.

Title