VTE180-2N42482 – Cylindrical Photoelectric Sensors – SICK Sensor

USD $ 70.35

SKU: SICK 6041809

SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.

Part Number: 6041809
Photoelectric Sensor Model: VTE180-2N42482
OEM Spec Ref 

Features

Sensor/ detection principle Photoelectric proximity sensor, Energetic
Dimensions (W x H x D) 18 mm x 18 mm x 69.8 mm
Housing design (light emission) Cylindrical
Housing length 69.8 mm
Thread diameter (housing) M18 x 1
Optical axis Axial
Sensing range max. 1 mm … 1,100 mm 1)
Sensing range 1 mm … 800 mm 1)
Type of light Visible red light
Light source LED 2)
Light spot size (distance) Ø 30 mm (800 mm)
Angle of dispersion Approx. 1.2°
Wave length 645 nm
Adjustment Potentiometer, 270° (Sensing range)
  • 1) Object with 90 % reflectance (referred to standard white, DIN 5033).
  • 2) Average service life: 100,000 h at TU = +25 °C.

Mechanics/electronics

Supply voltage 10 V DC … 30 V DC 1)
Ripple ± 10 % 2)
Current consumption 30 mA 3)
Switching output NPN 4)
Switching mode Light/dark switching 4)
Switching mode selector Selectable via L/D control cable
Signal voltage NPN HIGH/LOW Approx. VS / < 1.8 V
Output current Imax. ≤ 100 mA
Response time ≤ 0.5 ms 5)
Switching frequency 1,000 Hz 6)
Connection type Male connector M12, 4-pin
Circuit protection 7)

8)

9)

Protection class III
Weight 47 g
Housing material Metal, Nickel-plated brass and PC
Optics material Plastic, PMMA
Enclosure rating IP67
Items supplied Fastening nuts (2 x)
Ambient operating temperature –25 °C … +55 °C
Ambient storage temperature –40 °C … +70 °C
UL File No. NRKH2.E300503 & NRKH8.E300503
  • 1) Limit values when operated in short-circuit protected network: max. 8 A.
  • 2) May not exceed or fall below Uv tolerances.
  • 3) Without load.
  • 4) Control wire open: light switching L.ON.
  • 5) Signal transit time with resistive load.
  • 6) With light/dark ratio 1:1.
  • 7) A = VS connections reverse-polarity protected.
  • 8) B = inputs and output reverse-polarity protected.
  • 9) D = outputs overcurrent and short-circuit protected.
Weight 0.073 kg
Dimensions 8.0 × 4.0 × 10.0 cm