1. Checking an insert in an assembly nest
An assembly nest can present an insert at a repeatable distance in front of the axial red optical face. The potentiometer establishes the sensing setting using representative inserts and empty nests, while the L/D wire establishes the intended NPN signal behavior. External inspection logic samples the output after the assembly settles, with setup checking actual reflectance, placement tolerance and unwanted background returns.
Problem Solved
An insert-present reference helps external inspection logic identify an empty assembly location, using adjustable reflected-light sensing and a repeatable target presentation checked for the actual nest.
Insert presence
Axial sensing
L/D control
2. Counting separated tabs along a component guide
A component guide can move separated opaque tabs through the axial sensing spot at a controlled gap. External counting logic evaluates the NPN switching transitions after the potentiometer and L/D control wire establish the optical and electrical conditions. Commissioning checks tab reflectance, optical coverage, part gaps and speed against the reference-white range, response time and switching-frequency specification.
Problem Solved
A tab-passage reference helps an external counter register separated features from one mounting side, using adjusted optical conditions and a switching rate checked for the actual feed.
Tab counting
NPN signal
Adjustable sensing
3. Monitoring opaque material supply at a feed station
A feed station can present a defined opaque material surface at a stable axial sensing distance. External process logic evaluates the selected NPN state for material presence or loss of supply. Setup adjusts the potentiometer using actual material and checks surface variation, flutter and background reflections, while the L/D control wire matches the signal behavior to the connected process input.
Problem Solved
A material-present reference helps external process logic recognize loss of opaque feed at the checked location, using a sensing setting and signal behavior established for the actual installation.
Feed presence
Opaque material
Control-wire selection