$ 22.31
Main | |
Part Number | LC1K0910M7 |
Product Series | TeSys |
product type | Contactor |
product name | TeSys K |
Applications | Remote control |
Application field of contactor | Applied to AC loads with power factor greater than or equal to 0.95 |
Applied to non-inductive or slightly inductive loads, resistance furnaces | |
Additional information | |
use category | AC-4 |
AC-3 | |
AC-1 | |
AC-3e | |
number of poles | 3P |
power pole contact composition | 3 NO |
Rated operating current [Ie] | 20 A 50 °C) at <= 440 V AC AC-1 for power circuit |
9 A at <= 440 V AC AC-3 for power circuit | |
16 A at 70 °C) at 690 V AC AC- 1 for power circuit | |
9 A at <= 440 V AC AC-3e for power circuit | |
Control loop characteristics | AC at 50/60 Hz |
Control circuit voltage | 220…230 V AC 50/60 Hz |
Motor power (kW) | 2.2 kW at 220…230 V AC 50/60 Hz AC-3 |
4 kW at 380…415 V AC 50/60 Hz AC-3 | |
4 kW at 440 V AC 50/60 Hz AC-3 | |
4 kW at 480 V AC 50/60 Hz AC-3 | |
4 kW at 500…600 V AC 50/60 Hz AC-3 | |
4 kW at 660…690 V AC 50 /60 Hz AC-3 | |
2.2 kW at 400 V AC 50/60 Hz AC-4 | |
2.2 kW at 220…230 V AC 50/60 Hz AC-3e | |
4 kW at 380…415 V AC 50/60 Hz AC-3e | |
4 kW at 440 V AC 50/60 Hz AC-3e | |
4 kW at 480 V AC 50/60 Hz AC-3e | |
4 kW at 500…600 V AC 50/60 Hz AC-3e | |
4 kW at 660…690 V AC 50/60 Hz AC-3e | |
Auxiliary contact type | 1 NO |
Overvoltage category | III |
Conventional thermal current [Ith] | 20 A at <50 °C for power circuits |
10 A at <50 °C for signal circuits | |
Rated making capacity [Irms] | 110 A AC for power circuits according to NF C 63-110 |
110 A AC for power circuits according to IEC 60947 | |
110 A AC for signal circuits according to IEC 60947 | |
Rated breaking capacity | 110 A at 415 V conforming to IEC 60947 |
110 A at 440 V conforming to IEC 60947 | |
80 A at 500 V conforming to IEC 60947 | |
110 A at 220…230 V conforming to IEC 60947 | |
110 A at 380 …400 V conforming to IEC 60947 | |
70 A at 660…690 V conforming to IEC 60947 | |
Fuses for use with relays | 25 A gG at <= 440 V for power circuits |
25 A aM for power circuits | |
10 A gG for signal circuits according to IEC 60947 | |
10 A gG for signal circuits according to VDE 0660 | |
average impedance | 3 mΩ – Ith 20 A 50 Hz for power circuits |
Insulation resistance | > 10 MΩ for signal loops |
(~50Hz pickup) power consumption (VA) | 30VA 20°C) |
(~50Hz hold) power consumption (VA) | 4.5VA 20°C) |
heat dissipation | 1.3W |
Control voltage limit | Operating: 0.85…1.1 Uc 50 °C) |
Release: 0.2…0.75 Uc 50 °C) | |
operating frequency | 3600 times/hour |
Auxiliary contact type | Type Momentary 1 NO |
Signal loop frequency | ≤ 400Hz |
Minimum switching current [Imin] | 5 mA for signal loop |
Minimum switching voltage | 17 V for signal return |
action time | 10…20 ms coil discharging and NO opening |
10…20 ms coil energizing and NO contact closing | |
Safety and reliability level | B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 |
B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 | |
non-overlapping gap | 0.5 mm |
Shock and vibration resistance | Shock resistance in X direction, contacts closed: 10 gn (11ms) conforming to IEC 60068-2-27 |
Shock resistance in Y direction, contacts closed: 15 gn (11ms) conforming to IEC 60068-2 -27 | |
Shock resistance in the direction of the Z axis, with contacts closed: 15 gn (11ms) conforming to IEC 60068-2-27 | |
Shock resistance in the direction of the X axis, contacts open: 6 gn (11ms) conforming to IEC 60068 -2-27 | |
Shock resistance in Y-axis direction, contact open state: 10 gn (11ms) conforming to IEC 60068-2-27 | |
Shock resistance in Z-axis direction, contact open state: 10 gn (11ms) conforming IEC 60068-2-27 | |
shock resistance with contacts closed: 4 gn (5…300 Hz) conforming to IEC 60068-2-6 | |
shock resistance with contacts open: 2 gn (5…300 Hz) conforming to IEC 60068 -2-6 | |
environment | |
certified product | CSA |
UL | |
UKCA | |
Protective measures | TC conforming to IEC 60068 |
TC conforming to DIN 50016 | |
working altitude | 2000 meters without |
flame retardant | V1 Conforms to UL 94 |
requirements2 Conforms to NF F 16-101 | |
requirements2 Conforms to NF F 16-102 | |
packaging unit | |
Unit Type of Package 1 | PCE |
Number of Units in Package 1 | 1 |
Package 1 Height | 5cm |
Package 1 Width | 6cm |
Package 1 Length | 6.5cm |
Package 1 Weight | 178g |
Unit Type of Package 2 | S02 |
Number of Units in Package 2 | 50 |
Package 2 Height | 15cm |
Package 2 Width | 30cm |
Package 2 Length | 40cm |
Package 2 Weight | 9.149 kg |
Unit Type of Package 3 | P06 |
Number of Units in Package 3 | 800 |
Package 3 Height | 75cm |
Package 3 Width | 80cm |
Package 3 Length | 60cm |
Package 3 Weight | 154.384 kg |
contract warranty | |
Warranty | 18 months |
Weight | 0.178 kg |
---|---|
Dimensions | 6.5 × 6.0 × 5.0 cm |
INOSAKI Limited
RM B 5/F Gaylord Comm,
Bldg 114-118 Lockhart Rd.
Hong Kong
INOSAKI Sdn. Bhd.
2-1-9, Ground Floor, One Square, Tingkat Mahsuri 1,
11900 Bayan Lepas, Penan
INOSAKI Pte. Ltd.
101 Upper Cross Street,
No. 06-17, People’s Park Centre,
Singapore (058357)