$ 18.63
| Main information | |
| Part Number | LC1D098F7C |
| Product Series | TeSys Deca |
| Product Series | TeSys Deca |
| product type | Contactor |
| product short name | LC1D |
| Application field of contactor | Applied to non-inductive or micro-inductive load, resistance furnace |
| use category | AC-1 |
| number of poles | 4P |
| Rated working voltage [Ue] | Power circuit: <= 690 V AC 25…400 Hz |
| Power circuit: <= 225 V DC | |
| Rated operating current [Ie] | 20 A 60 °C) at <= 440 V AC AC-1 for power circuits |
| [Uc] control circuit voltage | 110V AC 50/60Hz |
| Additional information | |
| model | LC1D |
| Loop contact type | 2 NO + 2 NC |
| protection cap | None |
| Conventional thermal current [Ith] | 10 A at <60 °C for signal circuits |
| 20 A at <60 °C for power circuits | |
| Rated short-time withstand current [Icw] | 105 A at <40 °C – 10 s for power circuit |
| 210 A at <40 °C – 1 s for power circuit | |
| 30 A at <40 °C – 10 min for power circuit | |
| 61 A at <40 °C – 1 minute for power circuit | |
| 100 A – 1 s for signal circuit | |
| 120 A – 500 ms for signal circuit | |
| 140 A – 100 ms for signal circuit | |
| Fuses for use with relays | 10 A gG for signal circuits according to IEC 60947-5-1 |
| 25 A gG at <= 690 V for power circuits type 1 | |
| 20 A gG for power circuits for type 2 at <= 690 V | |
| average impedance | 2.5 mΩ – Ith 25 A 50 Hz for power loop |
| Rated insulation voltage [Ui] | Power circuit: 690 V conforming to IEC 60947-4-1 |
| Signal circuit: 690 V conforming to IEC 60947-1 | |
| Overvoltage category | III |
| pollution level | 3 |
| Rated impulse withstand voltage [Uimp] | 6 kV according to IEC 60947 |
| Safety and reliability level | B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 |
| B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 | |
| Mechanical life | 15 Mcycles |
| Electrical life | 0.6 Mcycles 25 A AC-1 at Ue <= 440 V |
| 2 Mcycles 9 A AC-3 at Ue <= 440 V | |
| 2 Mcycles 6.6 A AC-3 at Ue at 660/690 V | |
| Control loop characteristics | AC at 50/60 Hz |
| Surge Suppression Module | No built-in surge suppression module |
| Control voltage limit | 0.3…0.6 Uc -40…60 °C release 50/60 Hz |
| 0.8…1.1 Uc -40…60 °C run 50 Hz | |
| 0.85…1.1 Uc -40…60 °C run 60 Hz | |
| (~50Hz pickup) power consumption (VA) | 70 VA 60 Hz 0.75 20 °C) |
| 70 VA 50 Hz 0.75 20 °C) | |
| (~50Hz hold) power consumption (VA) | 7.5 VA 60 Hz 0.3 20 °C) |
| 7 VA 50 Hz 0.3 20 °C) | |
| heat dissipation | 2…3 W at 50/60 Hz |
| action time | 12…22 ms close |
| 4…19 ms break | |
| operating frequency | 3600 cycles/h at <60 °C |
| Wiring capacity | Power circuit: screw fastening1 1…4 mm² Lug O.D. Ø: 8 mm Cable option: flexible cord without wire terminal Power Circuit: |
| screw fastening2 1…4 mm² Lug O.D. Ø: 8 mm Cable Selection: flexible cord without wire terminals | |
| Power circuit: screw fastening1 1…4 mm² Lug outer diameter Ø: 8 mm Cable selection: flexible cord with wire terminal Power | |
| circuit: screw fastening2 1…2.5 mm² Lug outer diameter Ø: 8 mm Cable option: flexible with wire terminals Power | |
| circuit: screw fastening1 1…4 mm² Lug outer diameter Ø: 8 mm Cable option: Solid without wire terminals Power | |
| circuit : Bolt fastening2 1…4 mm² Lug O.D. Ø: 8 mm Cable option: Rigid without wire terminals | |
| Control circuit: Bolt tight1 1…4 mm² Cable option: Flexible wire without wire terminals | |
| Control circuit: screw-on2 1…4 mm² Cable option: flexible without cable terminals | |
| Control circuit: screw-on1 1…4 mm² cable option: flexible with cable terminals | |
| Control circuit: screw-on2 1…2.5 mm² cable selection: flexible wire with wire terminals | |
| control circuit: screw fastened1 1…4 mm² cable selection: rigid without wire terminal | |
| control circuit: screw fastened2 1…4 mm² cable selection : Hard wire without wire terminal | |
| Tightening torque | Power circuit: 1.7 Nm via screwdriver Ø 6 flat |
| power circuit: 1.7 Nm via screwdriver No 2 Phillips screw | |
| control circuit: 1.7 Nm via screwdriver Ø 6 flat | |
| control circuit: 1.7 Nm via screw Screwdriver No. 2 for fastening Phillips screw | |
| Power circuit: 1.7 Nm Screwdriver Ø 6 flat-blade screw via cable connector: M3.5 Power circuit | |
| : 1.7 Nm Phillips screw driver No. 2 via cable connector Screw: M3.5 | |
| Control circuit: 1.7 Nm Screwdriver pozidriv No 2 for screw tightening | |
| Power circuit: 1.7 Nm Screwdriver pozidriv No 2 for screw tightening | |
| Auxiliary contact type | 1 NO + 1 NC |
| Auxiliary contact type | Type Mechanical connection 1 NO + 1 NC conforming to IEC 60947-5-1 |
| Type mirrored with main contact status 1 NC conforming to IEC 60947-4-1 | |
| Signal loop frequency | 25…400Hz |
| Minimum switching voltage | 17 V for signal return |
| Minimum switching current [Imin] | 5 mA for signal loop |
| Insulation resistance | > 10 MΩ for signal loops |
| non-overlapping time | 1.5 ms between de-energized NC and NO contacts |
| 1.5 ms between energized NC and NO contacts | |
| installation method | DIN rail installation |
| base plate installation | |
| Environment | |
| standard | GB 14048.4 |
| IEC 60947-4-1 | |
| certified product | CCC |
| CE | |
| UKCA | |
| IP protection class | IP2X front panel main circuit is suitable for screwed |
| IP2X front panel coil circuit is suitable for screwed | |
| Protective measures | TH conforms to IEC 60068-2-30 |
| ambient air temperature | -40…60 °C operation |
| 60…70 °C with derating | |
| -60…80 °C storage | |
| working altitude | 3000 m None |
| Fire resistance and abnormal high temperature resistance | 850 °C conforming to IEC 60695-2-11 |
| Shock and vibration resistance | Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed ( 4 |
| gn (5…300 Hz)) conforming to IEC 60068-2-6 | |
| Shock performance 11 ms with contacts open (10 gn) conforming to IEC 60068-2-27 | |
| Shock resistance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27 | |
| high | 85 mm |
| width | 45 mm |
| depth | 92 mm |
| product weight | 0.365 kg |
| Packaging unit | |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |