TeSys Deca – LC1D – 3 Poles (3NO) Contactor, 38A – Schneider Contactors & Reversing Contactors

USD $ 26.04USD $ 63.42

SKU: N/A

Specifications

Main
Part Number LC1D38B7C LC1D38BDC LC1D38CC7C LC1D38E7C
Product Series TeSys Deca TeSys Deca TeSys Deca TeSys Deca
Product Series TeSys Deca TeSys Deca TeSys Deca TeSys Deca
product type Contactor Contactor Contactor Contactor
product short name LC1D LC1D LC1D LC1D
Application field of contactor Applied to non-inductive or micro-inductive loads, and
resistance furnaces to AC loads with a power factor greater than or equal to 0.95
Applied to AC loads with power factor greater than or equal to 0.95
Applied to non-inductive or slightly inductive loads, resistance furnaces
Applied to AC loads with power factor greater than or equal to 0.95
Applied to non-inductive or slightly inductive loads, resistance furnaces
Applied to AC loads with power factor greater than or equal to 0.95
Applied to non-inductive or slightly inductive loads, resistance furnaces
use category AC-4
AC-1
AC-3
AC-3e
AC-4
AC-1
AC-3
AC-3e
AC-4
AC-1
AC-3
AC-3e
AC-4
AC-1
AC-3
AC-3e
number of poles 3P 3P 3P 3P
Rated working voltage [Ue] Power circuit: <= 690 V AC 25…400 Hz
Power circuit: <= 225 V DC
Power circuit: <= 690 V AC 25…400 Hz
Power circuit: <= 225 V DC
Power circuit: <= 690 V AC 25…400 Hz
Power circuit: <= 225 V DC
Power circuit: <= 690 V AC 25…400 Hz
Power circuit: <= 225 V DC
Rated operating current [Ie] 50 A 60 °C) at <= 440 V AC AC-1 for power circuit
38 A 60 °C) at <= 440 V AC AC-3 for power circuit
38 A 60 °C) at< = 440 V AC AC-3e for power circuit
50 A 60 °C) at <= 440 V AC AC-1 for power circuit
38 A 60 °C) at <= 440 V AC AC-3 for power circuit
38 A 60 °C) at< = 440 V AC AC-3e for power circuit
50 A 60 °C) at <= 440 V AC AC-1 for power circuit
38 A 60 °C) at <= 440 V AC AC-3 for power circuit
38 A 60 °C) at< = 440 V AC AC-3e for power circuit
50 A 60 °C) at <= 440 V AC AC-1 for power circuit
38 A 60 °C) at <= 440 V AC AC-3 for power circuit
38 A 60 °C) at< = 440 V AC AC-3e for power circuit
[Uc] control circuit voltage 24 V AC 50/60 Hz 24 V DC 36 V AC 50/60 Hz 48 V AC 50/60 Hz
Additional information
Motor power (kW) 18.5 kW at 500 V AC 50/60 Hz (AC-3)
18.5 kW at 660/690 V AC 50/60 Hz (AC-3)
7.5 kW at 400 V AC 50/60 Hz (AC -4)
18.5 kW at 380/400 V AC 50/60 Hz (AC-3)
9 kW at 220/240 V AC 50/60 Hz (AC-3)
18.5 kW at 415/440 V AC 50/60 Hz (AC-3)
18.5 kW at 500 V AC 50/60 Hz (AC-3e)
18.5 kW at 660/690 V AC 50/60 Hz (AC-3e)
18.5 kW at… at 380/400 V AC 50/60 Hz (AC-3e)
9 kW at 220/240 V AC 50/60 Hz (AC-3e)
18.5 kW at 415/440 V AC 50/60 Hz (AC -3e)
18.5 kW at 500 V AC 50/60 Hz (AC-3)
18.5 kW at 660/690 V AC 50/60 Hz (AC-3)
18.5 kW at 380/400 V AC 50/60 Hz (AC-3)
9 kW at 220/240 V AC 50/60 Hz (AC-3)
18.5 kW at 415/440 V AC 50/60 Hz (AC-3)
18.5 kW at 500 V AC 50/60 Hz (AC-3e)
18.5 kW at 660/690 V AC 50/60 Hz (AC-3e)
18.5 kW at 380/400 V AC 50/60 Hz (AC-3e)
9 kW at 220/240 V AC 50/60 Hz (AC-3e)
18.5 kW at 415/440 V AC 50/60 Hz (AC-3e)
18.5 kW at 500 V AC 50/60 Hz (AC-3)
18.5 kW at 660/690 V AC 50/60 Hz (AC-3)
18.5 kW at 380/400 V AC 50/60 Hz (AC-3)
9 kW at 220/240 V AC 50/60 Hz (AC-3)
18.5 kW at 415/440 V AC 50/60 Hz (AC-3)
18.5 kW at 500 V AC 50/60 Hz (AC-3e)
18.5 kW at 660/690 V AC 50/60 Hz (AC-3e)
18.5 kW at 380/400 V AC 50/60 Hz (AC-3e)
9 kW at 220/240 V AC 50/60 Hz (AC-3e)
18.5 kW at 415/440 V AC 50/60 Hz (AC-3e)
18.5 kW at 500 V AC 50/60 Hz (AC-3)
18.5 kW at 660/690 V AC 50/60 Hz (AC-3)
18.5 kW at 380/400 V AC 50/60 Hz (AC-3)
9 kW at 220/240 V AC 50/60 Hz (AC-3)
18.5 kW at 415/440 V AC 50/60 Hz (AC-3)
18.5 kW at 500 V AC 50/60 Hz (AC-3e)
18.5 kW at 660/690 V AC 50/60 Hz (AC-3e)
18.5 kW at 380/400 V AC 50/60 Hz (AC-3e)
9 kW at 220/240 V AC 50/60 Hz (AC-3e)
18.5 kW at 415/440 V AC 50/60 Hz (AC-3e)
model LC1D LC1D LC1D LC1D
Loop contact type 3 NO 3 NO 3 NO 3 NO
protection cap None None None None
Conventional thermal current [Ith] 10 A at <60 °C for signal circuits
50 A at <60 °C for power circuits
10 A at <60 °C for signal circuits
50 A at <60 °C for power circuits
10 A at <60 °C for signal circuits
50 A at <60 °C for power circuits
10 A at <60 °C for signal circuits
50 A at <60 °C for power circuits
Rated short-time withstand current [Icw] 430 A at <40 °C – 1 s for power circuit
60 A at <40 °C – 10 min for power circuit
150 A at <40 °C – 1 min for power circuit
310 A at <40 °C – 10 s for power circuit
100 A – 1 s for signal circuit
120 A – 500 ms for signal circuit
140 A – 100 ms for signal circuit
430 A at <40 °C – 1 s for power circuit
60 A at <40 °C – 10 min for power circuit
150 A at <40 °C – 1 min for power circuit
310 A at <40 °C – 10 s for power circuit
100 A – 1 s for signal circuit
120 A – 500 ms for signal circuit
140 A – 100 ms for signal circuit
430 A at <40 °C – 1 s for power circuit
60 A at <40 °C – 10 min for power circuit
150 A at <40 °C – 1 min for power circuit
310 A at <40 °C – 10 s for power circuit
100 A – 1 s for signal circuit
120 A – 500 ms for signal circuit
140 A – 100 ms for signal circuit
430 A at <40 °C – 1 s for power circuit
60 A at <40 °C – 10 min for power circuit
150 A at <40 °C – 1 min for power circuit
310 A at <40 °C – 10 s for power circuit
100 A – 1 s for signal circuit
120 A – 500 ms for signal circuit
140 A – 100 ms for signal circuit
Fuses for use with relays 10 A gG for signal circuits according to IEC 60947-5-1
63 A gG at <= 690 V for power circuits type 1
63 A gG for power circuits for type 2 at <= 690 V
10 A gG for signal circuits according to IEC 60947-5-1
63 A gG at <= 690 V for power circuits type 1
63 A gG for power circuits for type 2 at <= 690 V
10 A gG for signal circuits according to IEC 60947-5-1
63 A gG at <= 690 V for power circuits type 1
63 A gG for power circuits for type 2 at <= 690 V
10 A gG for signal circuits according to IEC 60947-5-1
63 A gG at <= 690 V for power circuits type 1
63 A gG for power circuits for type 2 at <= 690 V
average impedance 2 mΩ – Ith 50 A 50 Hz for power circuits 2 mΩ – Ith 50 A 50 Hz for power circuits 2 mΩ – Ith 50 A 50 Hz for power circuits 2 mΩ – Ith 50 A 50 Hz for power circuits
Rated insulation voltage [Ui] Power circuit: 690 V conforming to IEC 60947-4-1
Signal circuit: 690 V conforming to IEC 60947-1
Power circuit: 690 V conforming to IEC 60947-4-1
Signal circuit: 690 V conforming to IEC 60947-1
Power circuit: 690 V conforming to IEC 60947-4-1
Signal circuit: 690 V conforming to IEC 60947-1
Power circuit: 690 V conforming to IEC 60947-4-1
Signal circuit: 690 V conforming to IEC 60947-1
Overvoltage category III III III III
pollution level 3 3 3 3
Rated impulse withstand voltage [Uimp] 6 kV according to IEC 60947 6 kV according to IEC 60947 6 kV according to IEC 60947 6 kV according to IEC 60947
Safety and reliability level B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1
B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1
B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1
B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1
B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1
B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1
B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1
B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1
Mechanical life 15 Mcycles 30 Mcycles 15 Mcycles 15 Mcycles
Electrical life 1.4 Mcycles 50 A AC-1 Ue <= 440 V
2.6 Mcycles 22 A AC-3 Ue 660/690 V
1.4 Mcycles 37 A AC-3 Ue <= 440 V
1.4 Mcycles 37 A AC-3e Ue <= 440 V at
2.6 Mcycles 22 A AC-3e at 660/690 V at Ue
1.4 Mcycles 50 A AC-1 Ue <= 440 V
2.6 Mcycles 22 A AC-3 Ue 660/690 V
1.4 Mcycles 37 A AC-3 Ue <= 440 V
1.4 Mcycles 37 A AC-3e Ue <= 440 V at
2.6 Mcycles 22 A AC-3e at 660/690 V at Ue
1.4 Mcycles 50 A AC-1 Ue <= 440 V
2.6 Mcycles 22 A AC-3 Ue 660/690 V
1.4 Mcycles 37 A AC-3 Ue <= 440 V
1.4 Mcycles 37 A AC-3e Ue <= 440 V at
2.6 Mcycles 22 A AC-3e at 660/690 V at Ue
1.4 Mcycles 50 A AC-1 Ue <= 440 V
2.6 Mcycles 22 A AC-3 Ue 660/690 V
1.4 Mcycles 37 A AC-3 Ue <= 440 V
1.4 Mcycles 37 A AC-3e Ue <= 440 V at
2.6 Mcycles 22 A AC-3e at 660/690 V at Ue
Control loop characteristics AC at 50/60 Hz DC standard AC at 50/60 Hz AC at 50/60 Hz
Surge Suppression Module No built-in surge suppression module Built-in bidirectional peak current limiting diode No built-in surge suppression module No built-in surge suppression module
Control voltage limit 0.3…0.6 Uc -40…60 °C release 50/60 Hz
0.8…1.1 Uc -40…60 °C run 50 Hz
0.85…1.1 Uc -40…60 °C run 60 Hz
0.1…0.25 Uc -40…60 °C release
0.7…1.25 Uc -40…60 °C run
0.3…0.6 Uc -40…60 °C release 50/60 Hz
0.8…1.1 Uc -40…60 °C run 50 Hz
0.85…1.1 Uc -40…60 °C run 60 Hz
0.3…0.6 Uc -40…60 °C release 50/60 Hz
0.8…1.1 Uc -40…60 °C run 50 Hz
0.85…1.1 Uc -40…60 °C run 60 Hz
(~50Hz pickup) power consumption (VA) 70 VA 60 Hz 0.75 20 °C)
70 VA 50 Hz 0.75 20 °C)
70 VA 60 Hz 0.75 20 °C)
70 VA 50 Hz 0.75 20 °C)
70 VA 60 Hz 0.75 20 °C)
70 VA 50 Hz 0.75 20 °C)
(~50Hz hold) power consumption (VA) 7.5 VA 60 Hz 0.3 20 °C)
7 VA 50 Hz 0.3 20 °C)
7.5 VA 60 Hz 0.3 20 °C)
7 VA 50 Hz 0.3 20 °C)
7.5 VA 60 Hz 0.3 20 °C)
7 VA 50 Hz 0.3 20 °C)
heat dissipation 2…3 W at 50/60 Hz 2…3 W at 50/60 Hz 2…3 W at 50/60 Hz
action time 12…22 ms close
4…19 ms break
55 ms to close,
20 ms to break
12…22 ms close
4…19 ms break
12…22 ms close
4…19 ms break
operating frequency 3600 cycles/h at <60 °C 3600 cycles/h at <60 °C 3600 cycles/h at <60 °C 3600 cycles/h at <60 °C
Wiring capacity Control circuit: Bolt fastening1 1…4 mm² Cable selection: Flexible cord without wire terminals
Control circuit: Bolt fastening2 1…4 mm² Cable selection: Flexible cord without wire terminal
Control circuit: Bolt fastening 1 1…4 mm² cable option: flexible cable with cable terminals
control circuit: screw fastened2 1…2.5 mm² cable option: flexible cable with cable terminal
control circuit: screw cable option1 1…4 mm² cable option : Solid wire without wire terminal
Control circuit: Bolt tight2 1…4 mm² Cable selection: Hard wire without wire terminal
Power circuit: Bolt fastened1 2.5…10 mm² Lug outer diameter Ø: 10 mm Cable Size selection: flexible cord without wire terminals
Power circuit: screw fastening2 2.5…10 mm² Lug outer diameter Ø: 10 mm Cable selection: flexible wire without wire terminal Power
circuit: screw tight1 1…10 mm² Lug outer diameter Ø: 10 mm Cable option: flexible cord with wire terminal
Power circuit: screw fastening2 1.5…6 mm² Lug outer diameter Ø: 10 mm Cable option: Flexible cord with wire terminal
Power circuit : Bolt fastening1 1.5…10 mm² Lug O.D. Ø: 10 mm Cable selection: Solid wire without wire terminal Power
circuit: Bolt fastening2 2.5…10 mm² Lug O.D. Ø: 10 mm Cable selection : Hard wire without wire terminal
Control circuit: Bolt fastening1 1…4 mm² Cable selection: Flexible cord without wire terminals
Control circuit: Bolt fastening2 1…4 mm² Cable selection: Flexible cord without wire terminal
Control circuit: Bolt fastening 1 1…4 mm² cable option: flexible cable with cable terminals
control circuit: screw fastened2 1…2.5 mm² cable option: flexible cable with cable terminal
control circuit: screw cable option1 1…4 mm² cable option : Solid wire without wire terminal
Control circuit: Bolt tight2 1…4 mm² Cable selection: Hard wire without wire terminal
Power circuit: Bolt fastened1 2.5…10 mm² Lug outer diameter Ø: 10 mm Cable Size selection: flexible cord without wire terminals
Power circuit: screw fastening2 2.5…10 mm² Lug outer diameter Ø: 10 mm Cable selection: flexible wire without wire terminal Power
circuit: screw tight1 1…10 mm² Lug outer diameter Ø: 10 mm Cable option: flexible cord with wire terminal
Power circuit: screw fastening2 1.5…6 mm² Lug outer diameter Ø: 10 mm Cable option: Flexible cord with wire terminal
Power circuit : Bolt fastening1 1.5…10 mm² Lug O.D. Ø: 10 mm Cable selection: Solid wire without wire terminal Power
circuit: Bolt fastening2 2.5…10 mm² Lug O.D. Ø: 10 mm Cable selection : Hard wire without wire terminal
Control circuit: Bolt fastening1 1…4 mm² Cable selection: Flexible cord without wire terminals
Control circuit: Bolt fastening2 1…4 mm² Cable selection: Flexible cord without wire terminal
Control circuit: Bolt fastening 1 1…4 mm² cable option: flexible cable with cable terminals
control circuit: screw fastened2 1…2.5 mm² cable option: flexible cable with cable terminal
control circuit: screw cable option1 1…4 mm² cable option : Solid wire without wire terminal
Control circuit: Bolt tight2 1…4 mm² Cable selection: Hard wire without wire terminal
Power circuit: Bolt fastened1 2.5…10 mm² Lug outer diameter Ø: 10 mm Cable Size selection: flexible cord without wire terminals
Power circuit: screw fastening2 2.5…10 mm² Lug outer diameter Ø: 10 mm Cable selection: flexible wire without wire terminal Power
circuit: screw tight1 1…10 mm² Lug outer diameter Ø: 10 mm Cable option: flexible cord with wire terminal
Power circuit: screw fastening2 1.5…6 mm² Lug outer diameter Ø: 10 mm Cable option: Flexible cord with wire terminal
Power circuit : Bolt fastening1 1.5…10 mm² Lug O.D. Ø: 10 mm Cable selection: Solid wire without wire terminal Power
circuit: Bolt fastening2 2.5…10 mm² Lug O.D. Ø: 10 mm Cable selection : Hard wire without wire terminal
Control circuit: Bolt fastening1 1…4 mm² Cable selection: Flexible cord without wire terminals
Control circuit: Bolt fastening2 1…4 mm² Cable selection: Flexible cord without wire terminal
Control circuit: Bolt fastening 1 1…4 mm² cable option: flexible cable with cable terminals
control circuit: screw fastened2 1…2.5 mm² cable option: flexible cable with cable terminal
control circuit: screw cable option1 1…4 mm² cable option : Solid wire without wire terminal
Control circuit: Bolt tight2 1…4 mm² Cable selection: Hard wire without wire terminal
Power circuit: Bolt fastened1 2.5…10 mm² Lug outer diameter Ø: 10 mm Cable Size selection: flexible cord without wire terminals
Power circuit: screw fastening2 2.5…10 mm² Lug outer diameter Ø: 10 mm Cable selection: flexible wire without wire terminal Power
circuit: screw tight1 1…10 mm² Lug outer diameter Ø: 10 mm Cable option: flexible cord with wire terminal
Power circuit: screw fastening2 1.5…6 mm² Lug outer diameter Ø: 10 mm Cable option: Flexible cord with wire terminal
Power circuit : Bolt fastening1 1.5…10 mm² Lug O.D. Ø: 10 mm Cable selection: Solid wire without wire terminal Power
circuit: Bolt fastening2 2.5…10 mm² Lug O.D. Ø: 10 mm Cable selection : Hard wire without wire terminal
Tightening torque Control circuit: 1.7 Nm via screwdriver Ø 6 flat
control circuit: 1.7 Nm via screwdriver No 2 Phillips screw
power circuit: 2.5 Nm via screwdriver Ø 6 flat
power circuit: 2.5 Nm via screw Screwdriver No. 2 for fastening Phillips screw
: 2.5 Nm Screwdriver Ø 6 flat-blade screw for cable connector: M4 Power
circuit: 2.5 Nm Phillips screw for cable connector No. 2 screw: M4
Power circuit: 2.5 Nm Tightening with bolts Control circuit with screwdriver pozidriv No 2
: 1.7 Nm Tighten by screw with screwdriver pozidriv No 2
Control circuit: 1.7 Nm via screwdriver Ø 6 flat
control circuit: 1.7 Nm via screwdriver No 2 Phillips screw
power circuit: 2.5 Nm via screwdriver Ø 6 flat
power circuit: 2.5 Nm via screw Screwdriver No. 2 for fastening Phillips screw
: 2.5 Nm Screwdriver Ø 6 flat-blade screw for cable connector: M4 Power
circuit: 2.5 Nm Phillips screw for cable connector No. 2 screw: M4
Power circuit: 2.5 Nm Tightening with bolts Control circuit with screwdriver pozidriv No 2
: 1.7 Nm Tighten by screw with screwdriver pozidriv No 2
Control circuit: 1.7 Nm via screwdriver Ø 6 flat
control circuit: 1.7 Nm via screwdriver No 2 Phillips screw
power circuit: 2.5 Nm via screwdriver Ø 6 flat
power circuit: 2.5 Nm via screw Screwdriver No. 2 for fastening Phillips screw
: 2.5 Nm Screwdriver Ø 6 flat-blade screw for cable connector: M4 Power
circuit: 2.5 Nm Phillips screw for cable connector No. 2 screw: M4
Power circuit: 2.5 Nm Tightening with bolts Control circuit with screwdriver pozidriv No 2
: 1.7 Nm Tighten by screw with screwdriver pozidriv No 2
Control circuit: 1.7 Nm via screwdriver Ø 6 flat
control circuit: 1.7 Nm via screwdriver No 2 Phillips screw
power circuit: 2.5 Nm via screwdriver Ø 6 flat
power circuit: 2.5 Nm via screw Screwdriver No. 2 for fastening Phillips screw
: 2.5 Nm Screwdriver Ø 6 flat-blade screw for cable connector: M4 Power
circuit: 2.5 Nm Phillips screw for cable connector No. 2 screw: M4
Power circuit: 2.5 Nm Tightening with bolts Control circuit with screwdriver pozidriv No 2
: 1.7 Nm Tighten by screw with screwdriver pozidriv No 2
Auxiliary contact type 1 NO + 1 NC 1 NO + 1 NC 1 NO + 1 NC 1 NO + 1 NC
Auxiliary contact type Type Mechanical connection 1 NO + 1 NC conforming to IEC 60947-5-1
Type mirrored with main contact status 1 NC conforming to IEC 60947-4-1
1 NO + 1 NC 1 NO + 1 NC 1 NO + 1 NC
Signal loop frequency 25…400Hz 25…400Hz 25…400Hz 25…400Hz
Minimum switching current [Imin] 5 mA for signal loop 5 mA for signal loop 5 mA for signal loop 5 mA for signal loop
Insulation resistance > 10 MΩ for signal loops > 10 MΩ for signal loops > 10 MΩ for signal loops > 10 MΩ for signal loops
non-overlapping time 1.5 ms between de-energized NC and NO contacts
1.5 ms between energized NC and NO contacts
1.5 ms between de-energized NC and NO contacts
1.5 ms between energized NC and NO contacts
1.5 ms between de-energized NC and NO contacts
1.5 ms between energized NC and NO contacts
1.5 ms between de-energized NC and NO contacts
1.5 ms between energized NC and NO contacts
installation method Chassis mounting
rail installation
Chassis mounting
rail installation
Chassis mounting
rail installation
DIN rail installation
base plate installation
environment
standard GB 14048.4
IEC 60947-4-1
GB 14048.4
IEC 60947-4-1
IEC 60947-4-1
GB 14048.4
IEC 60947-4-1
GB 14048.4
certified product CCC
CE
UKCA
CCC
CE
UKCA
CCC
CE
UKCA
CCC
CE
UKCA
IP protection class IP2x front panel for main circuits conforming to IEC 60529
IP2x front panel for coil circuits conforming to IEC 60529
IP2x front panel for main circuits conforming to IEC 60529
IP2x front panel for coil circuits conforming to IEC 60529
IP2x front panel for main circuits conforming to IEC 60529
IP2x front panel for coil circuits conforming to IEC 60529
IP2x front panel for main circuits conforming to IEC 60529
IP2x front panel for coil circuits conforming to IEC 60529
Protective measures TH conforms to IEC 60068-2-30 TH conforms to IEC 60068-2-30 TH conforms to IEC 60068-2-30 TH conforms to IEC 60068-2-30
ambient air temperature -40…60 °C operation
60…70 °C with derating
-60…80 °C storage
-40…60 °C operation
60…70 °C with derating
-60…80 °C storage
-40…60 °C operation
60…70 °C with derating
-60…80 °C storage
-40…60 °C operation
60…70 °C with derating
-60…80 °C storage
working altitude 3000 m None 3000 m None 3000 m None 3000 m None
Fire resistance and abnormal high temperature resistance 850 °C conforming to IEC 60695-2-11 850 °C conforming to IEC 60695-2-11 850 °C conforming to IEC 60695-2-11 850 °C conforming to IEC 60695-2-11
Shock and vibration resistance Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed ( 4
gn (5…300 Hz)) conforming to IEC 60068-2-6
Shock performance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27
Shock resistance 11 ms with contacts open (8 gn) conforming to IEC 60068-2-27
Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed ( 4
gn (5…300 Hz)) conforming to IEC 60068-2-6
Shock performance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27
Shock resistance 11 ms with contacts open (8 gn) conforming to IEC 60068-2-27
Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed ( 4
gn (5…300 Hz)) conforming to IEC 60068-2-6
Shock performance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27
Shock resistance 11 ms with contacts open (8 gn) conforming to IEC 60068-2-27
Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed ( 4
gn (5…300 Hz)) conforming to IEC 60068-2-6
Shock performance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27
Shock resistance 11 ms with contacts open (8 gn) conforming to IEC 60068-2-27
high 85 mm 85 mm 85 mm 85 mm
width 45 mm 45 mm 45 mm 45 mm
depth 92 mm 101 mm 92 mm 92 mm
Product Weight 0.38 kg 0.38kg 0.38kg 0.38kg
packaging unit
Unit Type of Package 1 PCE PCE PCE PCE
Number of Units in Package 1 1 1 1 1
Package 1 Height 5.359 cm 5.41 cm 8.8cm 8.8cm
Package 1 Width 8.874 cm 8.82cm 9.9 cm 9.9 cm
Package 1 Length 10.12cm 10.898 cm 5.1 cm 5.1 cm
Package 1 Weight 410.0g 580.0g 391.48g 391.48g
Unit Type of Package 2 S02 S02 CAR CAR
Number of Units in Package 2 Twenty one 20 Twenty one Twenty one
Package 2 Height 15.0cm 15.0cm 30.0cm 30.0cm
Package 2 Width 30.0cm 30.0cm 40.0cm 40.0cm
Package 2 Length 40.0cm 40.0cm 15.0cm 15.0cm
Package 2 Weight 9.141kg 12.091kg 8.271kg 8.271kg
Unit Type of Package 3 PAL PAL PAL PAL
Number of Units in Package 3 336 320 336 336
Package 3 Height 60.0cm 60.0cm 60.0cm 60.0cm
Package 3 Width 80.0cm 80.0cm 80.0cm 80.0cm
Package 3 Length 75.0cm 75.0cm 75.0cm 75.0cm
Package 3 Weight 146.016kg 199.024kg 131.736 kg 131.736 kg
contract warranty
Warranty 18 months 18 months 18 months 18 months

 

Main
Part Number LC1D38F7C LC1D38M7C LC1D38Q7C
Product Series TeSys Deca TeSys Deca TeSys Deca
Product Series TeSys Deca TeSys Deca TeSys Deca
product type Contactor Contactor Contactor
product short name LC1D LC1D LC1D
Application field of contactor Applied to AC loads with power factor greater than or equal to 0.95
Applied to non-inductive or slightly inductive loads, resistance furnaces
Applied to non-inductive or micro-inductive loads, and
resistance furnaces to AC loads with a power factor greater than or equal to 0.95
Applied to non-inductive or micro-inductive loads, and
resistance furnaces to AC loads with a power factor greater than or equal to 0.95
use category AC-4
AC-1
AC-3
AC-3e
AC-4
AC-1
AC-3
AC-3e
AC-4
AC-1
AC-3
AC-3e
number of poles 3P 3P 3P
Rated working voltage [Ue] Power circuit: <= 690 V AC 25…400 Hz
Power circuit: <= 225 V DC
Power circuit: <= 690 V AC 25…400 Hz
Power circuit: <= 225 V DC
Power circuit: <= 690 V AC 25…400 Hz
Power circuit: <= 225 V DC
Rated operating current [Ie] 50 A 60 °C) at <= 440 V AC AC-1 for power circuit
38 A 60 °C) at <= 440 V AC AC-3 for power circuit
38 A 60 °C) at< = 440 V AC AC-3e for power circuit
50 A 60 °C) at <= 440 V AC AC-1 for power circuit
38 A 60 °C) at <= 440 V AC AC-3 for power circuit
38 A 60 °C) at< = 440 V AC AC-3e for power circuit
50 A 60 °C) at <= 440 V AC AC-1 for power circuit
38 A 60 °C) at <= 440 V AC AC-3 for power circuit
38 A 60 °C) at< = 440 V AC AC-3e for power circuit
[Uc] control circuit voltage 110V AC 50/60Hz 230V AC 50/60Hz 380 V AC 50/60 Hz
Additional information
Motor power (kW) 18.5 kW at 500 V AC 50/60 Hz (AC-3)
18.5 kW at 660/690 V AC 50/60 Hz (AC-3)
18.5 kW at 380/400 V AC 50/60 Hz (AC-3)
9 kW at 220/240 V AC 50/60 Hz (AC-3)
18.5 kW at 415/440 V AC 50/60 Hz (AC-3)
18.5 kW at 500 V AC 50/60 Hz (AC-3e)
18.5 kW at 660/690 V AC 50/60 Hz (AC-3e)
18.5 kW at 380/400 V AC 50/60 Hz (AC-3e)
9 kW at 220/240 V AC 50/60 Hz (AC-3e)
18.5 kW at 415/440 V AC 50/60 Hz (AC-3e)
18.5 kW at 500 V AC 50/60 Hz (AC-3)
18.5 kW at 660/690 V AC 50/60 Hz (AC-3)
7.5 kW at 400 V AC 50/60 Hz (AC -4)
18.5 kW at 380/400 V AC 50/60 Hz (AC-3)
9 kW at 220/240 V AC 50/60 Hz (AC-3)
18.5 kW at 415/440 V AC 50/60 Hz (AC-3)
18.5 kW at 500 V AC 50/60 Hz (AC-3e)
18.5 kW at 660/690 V AC 50/60 Hz (AC-3e)
18.5 kW at… at 380/400 V AC 50/60 Hz (AC-3e)
9 kW at 220/240 V AC 50/60 Hz (AC-3e)
18.5 kW at 415/440 V AC 50/60 Hz (AC -3e)
18.5 kW at 500 V AC 50/60 Hz (AC-3)
18.5 kW at 660/690 V AC 50/60 Hz (AC-3)
7.5 kW at 400 V AC 50/60 Hz (AC -4)
18.5 kW at 380/400 V AC 50/60 Hz (AC-3)
9 kW at 220/240 V AC 50/60 Hz (AC-3)
18.5 kW at 415/440 V AC 50/60 Hz (AC-3)
18.5 kW at 500 V AC 50/60 Hz (AC-3e)
18.5 kW at 660/690 V AC 50/60 Hz (AC-3e)
18.5 kW at… at 380/400 V AC 50/60 Hz (AC-3e)
9 kW at 220/240 V AC 50/60 Hz (AC-3e)
18.5 kW at 415/440 V AC 50/60 Hz (AC -3e)
model LC1D LC1D LC1D
Loop contact type 3 NO 3 NO 3 NO
protection cap None None None
Conventional thermal current [Ith] 10 A at <60 °C for signal circuits
50 A at <60 °C for power circuits
10 A at <60 °C for signal circuits
50 A at <60 °C for power circuits
10 A at <60 °C for signal circuits
50 A at <60 °C for power circuits
Rated short-time withstand current [Icw] 430 A at <40 °C – 1 s for power circuit
60 A at <40 °C – 10 min for power circuit
150 A at <40 °C – 1 min for power circuit
310 A at <40 °C – 10 s for power circuit
100 A – 1 s for signal circuit
120 A – 500 ms for signal circuit
140 A – 100 ms for signal circuit
430 A at <40 °C – 1 s for power circuit
60 A at <40 °C – 10 min for power circuit
150 A at <40 °C – 1 min for power circuit
310 A at <40 °C – 10 s for power circuit
100 A – 1 s for signal circuit
120 A – 500 ms for signal circuit
140 A – 100 ms for signal circuit
430 A at <40 °C – 1 s for power circuit
60 A at <40 °C – 10 min for power circuit
150 A at <40 °C – 1 min for power circuit
310 A at <40 °C – 10 s for power circuit
100 A – 1 s for signal circuit
120 A – 500 ms for signal circuit
140 A – 100 ms for signal circuit
Fuses for use with relays 10 A gG for signal circuits according to IEC 60947-5-1
63 A gG at <= 690 V for power circuits type 1
63 A gG for power circuits for type 2 at <= 690 V
10 A gG for signal circuits according to IEC 60947-5-1
63 A gG at <= 690 V for power circuits type 1
63 A gG for power circuits for type 2 at <= 690 V
10 A gG for signal circuits according to IEC 60947-5-1
63 A gG at <= 690 V for power circuits type 1
63 A gG for power circuits for type 2 at <= 690 V
average impedance 2 mΩ – Ith 50 A 50 Hz for power circuits 2 mΩ – Ith 50 A 50 Hz for power circuits 2 mΩ – Ith 50 A 50 Hz for power circuits
Rated insulation voltage [Ui] Power circuit: 690 V conforming to IEC 60947-4-1
Signal circuit: 690 V conforming to IEC 60947-1
Power circuit: 690 V conforming to IEC 60947-4-1
Signal circuit: 690 V conforming to IEC 60947-1
Power circuit: 690 V conforming to IEC 60947-4-1
Signal circuit: 690 V conforming to IEC 60947-1
Overvoltage category III III III
pollution level 3 3 3
Rated impulse withstand voltage [Uimp] 6 kV according to IEC 60947 6 kV according to IEC 60947 6 kV according to IEC 60947
Safety and reliability level B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1
B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1
B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1
B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1
B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1
B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1
Mechanical life 15 Mcycles 15 Mcycles 15 Mcycles
Electrical life 1.4 Mcycles 50 A AC-1 Ue <= 440 V
2.6 Mcycles 22 A AC-3 Ue 660/690 V
1.4 Mcycles 37 A AC-3 Ue <= 440 V
1.4 Mcycles 37 A AC-3e Ue <= 440 V at
2.6 Mcycles 22 A AC-3e at 660/690 V at Ue
1.4 Mcycles 50 A AC-1 Ue <= 440 V
2.6 Mcycles 22 A AC-3 Ue 660/690 V
1.4 Mcycles 37 A AC-3 Ue <= 440 V
1.4 Mcycles 37 A AC-3e Ue <= 440 V at
2.6 Mcycles 22 A AC-3e at 660/690 V at Ue
1.4 Mcycles 50 A AC-1 Ue <= 440 V
2.6 Mcycles 22 A AC-3 Ue 660/690 V
1.4 Mcycles 37 A AC-3 Ue <= 440 V
1.4 Mcycles 37 A AC-3e Ue <= 440 V at
2.6 Mcycles 22 A AC-3e at 660/690 V at Ue
Control loop characteristics AC at 50/60 Hz AC at 50/60 Hz AC at 50/60 Hz
Surge Suppression Module No built-in surge suppression module No built-in surge suppression module No built-in surge suppression module
Control voltage limit 0.3…0.6 Uc -40…60 °C release 50/60 Hz
0.8…1.1 Uc -40…60 °C run 50 Hz
0.85…1.1 Uc -40…60 °C run 60 Hz
0.3…0.6 Uc -40…60 °C release 50/60 Hz
0.8…1.1 Uc -40…60 °C run 50 Hz
0.85…1.1 Uc -40…60 °C run 60 Hz
0.3…0.6 Uc -40…60 °C release 50/60 Hz
0.8…1.1 Uc -40…60 °C run 50 Hz
0.85…1.1 Uc -40…60 °C run 60 Hz
(~50Hz pickup) power consumption (VA) 70 VA 60 Hz 0.75 20 °C)
70 VA 50 Hz 0.75 20 °C)
70 VA 60 Hz 0.75 20 °C)
70 VA 50 Hz 0.75 20 °C)
70 VA 60 Hz 0.75 20 °C)
70 VA 50 Hz 0.75 20 °C)
(~50Hz hold) power consumption (VA) 7.5 VA 60 Hz 0.3 20 °C)
7 VA 50 Hz 0.3 20 °C)
7.5 VA 60 Hz 0.3 20 °C)
7 VA 50 Hz 0.3 20 °C)
7.5 VA 60 Hz 0.3 20 °C)
7 VA 50 Hz 0.3 20 °C)
heat dissipation 2…3 W at 50/60 Hz 2…3 W at 50/60 Hz 2…3 W at 50/60 Hz
action time 12…22 ms close
4…19 ms break
12…22 ms close
4…19 ms break
12…22 ms close
4…19 ms break
operating frequency 3600 cycles/h at <60 °C 3600 cycles/h at <60 °C 3600 cycles/h at <60 °C
Wiring capacity Control circuit: Bolt fastening1 1…4 mm² Cable selection: Flexible cord without wire terminals
Control circuit: Bolt fastening2 1…4 mm² Cable selection: Flexible cord without wire terminal
Control circuit: Bolt fastening 1 1…4 mm² cable option: flexible cable with cable terminals
control circuit: screw fastened2 1…2.5 mm² cable option: flexible cable with cable terminal
control circuit: screw cable option1 1…4 mm² cable option : Solid wire without wire terminal
Control circuit: Bolt tight2 1…4 mm² Cable selection: Hard wire without wire terminal
Power circuit: Bolt fastened1 2.5…10 mm² Lug outer diameter Ø: 10 mm Cable Size selection: flexible cord without wire terminals
Power circuit: screw fastening2 2.5…10 mm² Lug outer diameter Ø: 10 mm Cable selection: flexible wire without wire terminal Power
circuit: screw tight1 1…10 mm² Lug outer diameter Ø: 10 mm Cable option: flexible cord with wire terminal
Power circuit: screw fastening2 1.5…6 mm² Lug outer diameter Ø: 10 mm Cable option: Flexible cord with wire terminal
Power circuit : Bolt fastening1 1.5…10 mm² Lug O.D. Ø: 10 mm Cable selection: Solid wire without wire terminal Power
circuit: Bolt fastening2 2.5…10 mm² Lug O.D. Ø: 10 mm Cable selection : Hard wire without wire terminal
Control circuit: Bolt fastening1 1…4 mm² Cable selection: Flexible cord without wire terminals
Control circuit: Bolt fastening2 1…4 mm² Cable selection: Flexible cord without wire terminal
Control circuit: Bolt fastening 1 1…4 mm² cable option: flexible cable with cable terminals
control circuit: screw fastened2 1…2.5 mm² cable option: flexible cable with cable terminal
control circuit: screw cable option1 1…4 mm² cable option : Solid wire without wire terminal
Control circuit: Bolt tight2 1…4 mm² Cable selection: Hard wire without wire terminal
Power circuit: Bolt fastened1 2.5…10 mm² Lug outer diameter Ø: 10 mm Cable Size selection: flexible cord without wire terminals
Power circuit: screw fastening2 2.5…10 mm² Lug outer diameter Ø: 10 mm Cable selection: flexible wire without wire terminal Power
circuit: screw tight1 1…10 mm² Lug outer diameter Ø: 10 mm Cable option: flexible cord with wire terminal
Power circuit: screw fastening2 1.5…6 mm² Lug outer diameter Ø: 10 mm Cable option: Flexible cord with wire terminal
Power circuit : Bolt fastening1 1.5…10 mm² Lug O.D. Ø: 10 mm Cable selection: Solid wire without wire terminal Power
circuit: Bolt fastening2 2.5…10 mm² Lug O.D. Ø: 10 mm Cable selection : Hard wire without wire terminal
Control circuit: Bolt fastening1 1…4 mm² Cable selection: Flexible cord without wire terminals
Control circuit: Bolt fastening2 1…4 mm² Cable selection: Flexible cord without wire terminal
Control circuit: Bolt fastening 1 1…4 mm² cable option: flexible cable with cable terminals
control circuit: screw fastened2 1…2.5 mm² cable option: flexible cable with cable terminal
control circuit: screw cable option1 1…4 mm² cable option : Solid wire without wire terminal
Control circuit: Bolt tight2 1…4 mm² Cable selection: Hard wire without wire terminal
Power circuit: Bolt fastened1 2.5…10 mm² Lug outer diameter Ø: 10 mm Cable Size selection: flexible cord without wire terminals
Power circuit: screw fastening2 2.5…10 mm² Lug outer diameter Ø: 10 mm Cable selection: flexible wire without wire terminal Power
circuit: screw tight1 1…10 mm² Lug outer diameter Ø: 10 mm Cable option: flexible cord with wire terminal
Power circuit: screw fastening2 1.5…6 mm² Lug outer diameter Ø: 10 mm Cable option: Flexible cord with wire terminal
Power circuit : Bolt fastening1 1.5…10 mm² Lug O.D. Ø: 10 mm Cable selection: Solid wire without wire terminal Power
circuit: Bolt fastening2 2.5…10 mm² Lug O.D. Ø: 10 mm Cable selection : Hard wire without wire terminal
Tightening torque Control circuit: 1.7 Nm via screwdriver Ø 6 flat
control circuit: 1.7 Nm via screwdriver No 2 Phillips screw
power circuit: 2.5 Nm via screwdriver Ø 6 flat
power circuit: 2.5 Nm via screw Screwdriver No. 2 for fastening Phillips screw
: 2.5 Nm Screwdriver Ø 6 flat-blade screw for cable connector: M4 Power
circuit: 2.5 Nm Phillips screw for cable connector No. 2 screw: M4
Power circuit: 2.5 Nm Tightening with bolts Control circuit with screwdriver pozidriv No 2
: 1.7 Nm Tighten by screw with screwdriver pozidriv No 2
Control circuit: 1.7 Nm via screwdriver Ø 6 flat
control circuit: 1.7 Nm via screwdriver No 2 Phillips screw
power circuit: 2.5 Nm via screwdriver Ø 6 flat
power circuit: 2.5 Nm via screw Screwdriver No. 2 for fastening Phillips screw
: 2.5 Nm Screwdriver Ø 6 flat-blade screw for cable connector: M4 Power
circuit: 2.5 Nm Phillips screw for cable connector No. 2 screw: M4
Power circuit: 2.5 Nm Tightening with bolts Control circuit with screwdriver pozidriv No 2
: 1.7 Nm Tighten by screw with screwdriver pozidriv No 2
Control circuit: 1.7 Nm via screwdriver Ø 6 flat
control circuit: 1.7 Nm via screwdriver No 2 Phillips screw
power circuit: 2.5 Nm via screwdriver Ø 6 flat
power circuit: 2.5 Nm via screw Screwdriver No. 2 for fastening Phillips screw
: 2.5 Nm Screwdriver Ø 6 flat-blade screw for cable connector: M4 Power
circuit: 2.5 Nm Phillips screw for cable connector No. 2 screw: M4
Power circuit: 2.5 Nm Tightening with bolts Control circuit with screwdriver pozidriv No 2
: 1.7 Nm Tighten by screw with screwdriver pozidriv No 2
Auxiliary contact type 1 NO + 1 NC 1 NO + 1 NC 1 NO + 1 NC
Auxiliary contact type Type Mechanical connection 1 NO + 1 NC conforming to IEC 60947-5-1
Type mirrored with main contact status 1 NC conforming to IEC 60947-4-1
1 NO + 1 NC 1 NO + 1 NC
Signal loop frequency 25…400Hz 25…400Hz 25…400Hz
Minimum switching current [Imin] 5 mA for signal loop 5 mA for signal loop 5 mA for signal loop
Insulation resistance > 10 MΩ for signal loops > 10 MΩ for signal loops > 10 MΩ for signal loops
non-overlapping time 1.5 ms between de-energized NC and NO contacts
1.5 ms between energized NC and NO contacts
1.5 ms between de-energized NC and NO contacts
1.5 ms between energized NC and NO contacts
1.5 ms between de-energized NC and NO contacts
1.5 ms between energized NC and NO contacts
installation method Chassis mounting
rail installation
DIN rail installation
base plate installation
Chassis mounting
rail installation
environment
standard IEC 60947-4-1
GB 14048.4
IEC 60947-4-1
GB 14048.4
GB 14048.4
IEC 60947-4-1
certified product CCC
CE
UKCA
CCC
CE
UKCA
CCC
CE
UKCA
IP protection class IP2x front panel for main circuits conforming to IEC 60529
IP2x front panel for coil circuits conforming to IEC 60529
IP2x front panel for main circuits conforming to IEC 60529
IP2x front panel for coil circuits conforming to IEC 60529
IP2x front panel for main circuits conforming to IEC 60529
IP2x front panel for coil circuits conforming to IEC 60529
Protective measures TH conforms to IEC 60068-2-30 TH conforms to IEC 60068-2-30 TH conforms to IEC 60068-2-30
ambient air temperature -40…60 °C operation
60…70 °C with derating
-60…80 °C storage
-40…60 °C operation
60…70 °C with derating
-60…80 °C storage
-40…60 °C operation
60…70 °C with derating
-60…80 °C storage
working altitude 3000 m None 3000 m None 3000 m None
Fire resistance and abnormal high temperature resistance 850 °C conforming to IEC 60695-2-11 850 °C conforming to IEC 60695-2-11 850 °C conforming to IEC 60695-2-11
Shock and vibration resistance Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed ( 4
gn (5…300 Hz)) conforming to IEC 60068-2-6
Shock performance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27
Shock resistance 11 ms with contacts open (8 gn) conforming to IEC 60068-2-27
Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed ( 4
gn (5…300 Hz)) conforming to IEC 60068-2-6
Shock performance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27
Shock resistance 11 ms with contacts open (8 gn) conforming to IEC 60068-2-27
Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed ( 4
gn (5…300 Hz)) conforming to IEC 60068-2-6
Shock performance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27
Shock resistance 11 ms with contacts open (8 gn) conforming to IEC 60068-2-27
high 85 mm 85 mm 85 mm
width 45 mm 45 mm 45 mm
depth 92 mm 92 mm 92 mm
Product Weight 0.38 kg 0.38 kg 0.38kg
packaging unit
Unit Type of Package 1 PCE PCE PCE
Number of Units in Package 1 1 1 1
Package 1 Height 5.359 cm 5.112 cm 5.564 cm
Package 1 Width 8.765 cm 8.836 cm 8.984 cm
Package 1 Length 10.073 cm 10.029 cm 9.946 cm
Package 1 Weight 410.0g 410.0g 410.0g
Unit Type of Package 2 S02 S02 S02
Number of Units in Package 2 Twenty one Twenty one Twenty one
Package 2 Height 15.0cm 15.0cm 15.0cm
Package 2 Width 30.0cm 30.0cm 30.0cm
Package 2 Length 40.0cm 40.0cm 40.0cm
Package 2 Weight 9.03kg 9.03kg 9.04kg
Unit Type of Package 3 PAL PAL PAL
Number of Units in Package 3 336 336 336
Package 3 Height 60.0cm 60.0cm 60.0cm
Package 3 Width 80.0cm 80.0cm 80.0cm
Package 3 Length 75.0cm 75.0cm 75.0cm
Package 3 Weight 143.573 kg 148.704kg 147.776kg
contract warranty
Warranty 18 months 18 months 18 months

 

Weight N/A
Dimensions N/A