TeSys Deca – LC1D – 4 Poles (2NO + 2NC) Contactor, 20A – Schneider Contactors & Reversing Contactors
$ 16.94 – $ 18.04
SKU: N/A
Specifications
Main | |||
Part Number | LC1D098B7C | LC1D098E7C | LC1D098M7C |
Product Series | TeSys Deca | TeSys Deca | TeSys Deca |
Product Series | TeSys Deca | TeSys Deca | TeSys Deca |
product type | Contactor | Contactor | Contactor |
product short name | LC1D | LC1D | LC1D |
Application field of contactor | Applied to non-inductive or micro-inductive load, resistance furnace | Applied to non-inductive or micro-inductive load, resistance furnace | Applied to non-inductive or micro-inductive load, resistance furnace |
use category | AC-1 | AC-1 | AC-1 |
number of poles | 4P | 4P | 4P |
Rated working voltage [Ue] | Power circuit: <= 690 V AC 25…400 Hz Power circuit: <= 225 V DC |
Power circuit: <= 690 V AC 25…400 Hz Power circuit: <= 225 V DC |
Power circuit: <= 690 V AC 25…400 Hz Power circuit: <= 225 V DC |
Rated operating current [Ie] | 9 A 60 °C) at <= 440 V AC AC-3 for power circuits | 20 A 60 °C) at <= 440 V AC AC-1 for power circuits | 20 A 60 °C) at <= 440 V AC AC-1 for power circuits |
[Uc] control circuit voltage | 24 V AC 50/60 Hz | 48 V AC 50/60 Hz | 230V AC 50/60Hz |
Additional information | |||
model | LC1D | LC1D | LC1D |
Loop contact type | 2 NO + 2 NC | 2 NO + 2 NC | 2 NO + 2 NC |
protection cap | None | None | None |
Conventional thermal current [Ith] | 10 A at <60 °C for signal circuits 20 A at <60 °C for power circuits |
10 A at <60 °C for signal circuits 20 A at <60 °C for power circuits |
10 A at <60 °C for signal circuits 20 A at <60 °C for power circuits |
Rated short-time withstand current [Icw] | 105 A at <40 °C – 10 s for power circuit 210 A at <40 °C – 1 s for power circuit 30 A at <40 °C – 10 min for power circuit 61 A at <40 °C – 1 minute for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit |
105 A at <40 °C – 10 s for power circuit 210 A at <40 °C – 1 s for power circuit 30 A at <40 °C – 10 min for power circuit 61 A at <40 °C – 1 minute for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit |
105 A at <40 °C – 10 s for power circuit 210 A at <40 °C – 1 s for power circuit 30 A at <40 °C – 10 min for power circuit 61 A at <40 °C – 1 minute for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit |
Fuses for use with relays | 10 A gG for signal circuits according to IEC 60947-5-1 25 A gG at <= 690 V for power circuits type 1 20 A gG for power circuits for type 2 at <= 690 V |
10 A gG for signal circuits according to IEC 60947-5-1 25 A gG at <= 690 V for power circuits type 1 20 A gG for power circuits for type 2 at <= 690 V |
10 A gG for signal circuits according to IEC 60947-5-1 25 A gG at <= 690 V for power circuits type 1 20 A gG for power circuits for type 2 at <= 690 V |
average impedance | 2.5 mΩ – Ith 25 A 50 Hz for power loop | 2.5 mΩ – Ith 25 A 50 Hz for power loop | 2.5 mΩ – Ith 25 A 50 Hz for power loop |
Rated insulation voltage [Ui] | Power circuit: 690 V conforming to IEC 60947-4-1 Signal circuit: 690 V conforming to IEC 60947-1 |
Power circuit: 690 V conforming to IEC 60947-4-1 Signal circuit: 690 V conforming to IEC 60947-1 |
Power circuit: 690 V conforming to IEC 60947-4-1 Signal circuit: 690 V conforming to IEC 60947-1 |
Overvoltage category | III | III | III |
pollution level | 3 | 3 | 3 |
Rated impulse withstand voltage [Uimp] | 6 kV according to IEC 60947 | 6 kV according to IEC 60947 | 6 kV according to IEC 60947 |
Safety and reliability level | B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 |
B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 |
B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 |
Mechanical life | 15 Mcycles | 15 Mcycles | 15 Mcycles |
Electrical life | 0.6 Mcycles 25 A AC-1 at Ue <= 440 V 2 Mcycles 9 A AC-3 at Ue <= 440 V 2 Mcycles 6.6 A AC-3 at Ue at 660/690 V |
0.6 Mcycles 25 A AC-1 at Ue <= 440 V 2 Mcycles 9 A AC-3 at Ue <= 440 V 2 Mcycles 6.6 A AC-3 at Ue at 660/690 V |
0.6 Mcycles 25 A AC-1 at Ue <= 440 V 2 Mcycles 9 A AC-3 at Ue <= 440 V 2 Mcycles 6.6 A AC-3 at Ue at 660/690 V |
Control loop characteristics | AC at 50/60 Hz | AC at 50/60 Hz | AC at 50/60 Hz |
Surge Suppression Module | No built-in surge suppression module | No built-in surge suppression module | No built-in surge suppression module |
Control voltage limit | 0.3…0.6 Uc -40…60 °C release 50/60 Hz 0.8…1.1 Uc -40…60 °C run 50 Hz 0.85…1.1 Uc -40…60 °C run 60 Hz |
0.3…0.6 Uc -40…60 °C release 50/60 Hz 0.8…1.1 Uc -40…60 °C run 50 Hz 0.85…1.1 Uc -40…60 °C run 60 Hz |
0.3…0.6 Uc -40…60 °C release 50/60 Hz 0.8…1.1 Uc -40…60 °C run 50 Hz 0.85…1.1 Uc -40…60 °C run 60 Hz |
(~50Hz pickup) power consumption (VA) | 70 VA 60 Hz 0.75 20 °C) 70 VA 50 Hz 0.75 20 °C) |
70 VA 60 Hz 0.75 20 °C) 70 VA 50 Hz 0.75 20 °C) |
70 VA 60 Hz 0.75 20 °C) 70 VA 50 Hz 0.75 20 °C) |
(~50Hz hold) power consumption (VA) | 7.5 VA 60 Hz 0.3 20 °C) 7 VA 50 Hz 0.3 20 °C) |
7.5 VA 60 Hz 0.3 20 °C) 7 VA 50 Hz 0.3 20 °C) |
7.5 VA 60 Hz 0.3 20 °C) 7 VA 50 Hz 0.3 20 °C) |
heat dissipation | 2…3 W at 50/60 Hz | 2…3 W at 50/60 Hz | 2…3 W at 50/60 Hz |
action time | 12…22 ms close 4…19 ms break |
12…22 ms close 4…19 ms break |
12…22 ms close 4…19 ms break |
operating frequency | 3600 cycles/h at <60 °C | 3600 cycles/h at <60 °C | 3600 cycles/h at <60 °C |
Wiring capacity | Power circuit: screw fastening1 1…4 mm² Lug O.D. Ø: 8 mm Cable option: flexible cord without wire terminal Power Circuit: screw fastening2 1…4 mm² Lug O.D. Ø: 8 mm Cable Selection: flexible cord without wire terminals Power circuit: screw fastening1 1…4 mm² Lug outer diameter Ø: 8 mm Cable selection: flexible cord with wire terminal Power circuit: screw fastening2 1…2.5 mm² Lug outer diameter Ø: 8 mm Cable option: flexible with wire terminals Power circuit: screw fastening1 1…4 mm² Lug outer diameter Ø: 8 mm Cable option: Solid without wire terminals Power circuit : Bolt fastening2 1…4 mm² Lug O.D. Ø: 8 mm Cable option: Rigid without wire terminals Control circuit: Bolt tight1 1…4 mm² Cable option: Flexible wire without wire terminals Control circuit: screw-on2 1…4 mm² Cable option: flexible without cable terminals Control circuit: screw-on1 1…4 mm² cable option: flexible with cable terminals Control circuit: screw-on2 1…2.5 mm² cable selection: flexible wire with wire terminals control circuit: screw fastened1 1…4 mm² cable selection: rigid without wire terminal control circuit: screw fastened2 1…4 mm² cable selection : Hard wire without wire terminal |
Power circuit: screw fastening1 1…4 mm² Lug O.D. Ø: 8 mm Cable option: flexible cord without wire terminal Power Circuit: screw fastening2 1…4 mm² Lug O.D. Ø: 8 mm Cable Selection: flexible cord without wire terminals Power circuit: screw fastening1 1…4 mm² Lug outer diameter Ø: 8 mm Cable selection: flexible cord with wire terminal Power circuit: screw fastening2 1…2.5 mm² Lug outer diameter Ø: 8 mm Cable option: flexible with wire terminals Power circuit: screw fastening1 1…4 mm² Lug outer diameter Ø: 8 mm Cable option: Solid without wire terminals Power circuit : Bolt fastening2 1…4 mm² Lug O.D. Ø: 8 mm Cable option: Rigid without wire terminals Control circuit: Bolt tight1 1…4 mm² Cable option: Flexible wire without wire terminals Control circuit: screw-on2 1…4 mm² Cable option: flexible without cable terminals Control circuit: screw-on1 1…4 mm² cable option: flexible with cable terminals Control circuit: screw-on2 1…2.5 mm² cable selection: flexible wire with wire terminals control circuit: screw fastened1 1…4 mm² cable selection: rigid without wire terminal control circuit: screw fastened2 1…4 mm² cable selection : Hard wire without wire terminal |
Power circuit: screw fastening1 1…4 mm² Lug O.D. Ø: 8 mm Cable option: flexible cord without wire terminal Power Circuit: screw fastening2 1…4 mm² Lug O.D. Ø: 8 mm Cable Selection: flexible cord without wire terminals Power circuit: screw fastening1 1…4 mm² Lug outer diameter Ø: 8 mm Cable selection: flexible cord with wire terminal Power circuit: screw fastening2 1…2.5 mm² Lug outer diameter Ø: 8 mm Cable option: flexible with wire terminals Power circuit: screw fastening1 1…4 mm² Lug outer diameter Ø: 8 mm Cable option: Solid without wire terminals Power circuit : Bolt fastening2 1…4 mm² Lug O.D. Ø: 8 mm Cable option: Rigid without wire terminals Control circuit: Bolt tight1 1…4 mm² Cable option: Flexible wire without wire terminals Control circuit: screw-on2 1…4 mm² Cable option: flexible without cable terminals Control circuit: screw-on1 1…4 mm² cable option: flexible with cable terminals Control circuit: screw-on2 1…2.5 mm² cable selection: flexible wire with wire terminals control circuit: screw fastened1 1…4 mm² cable selection: rigid without wire terminal control circuit: screw fastened2 1…4 mm² cable selection : Hard wire without wire terminal |
Tightening torque | Power circuit: 1.7 Nm via screwdriver Ø 6 flat power circuit: 1.7 Nm via screwdriver No 2 Phillips screw control circuit: 1.7 Nm via screwdriver Ø 6 flat control circuit: 1.7 Nm via screw Screwdriver No. 2 for fastening Phillips screw Power circuit: 1.7 Nm Screwdriver Ø 6 flat-blade screw via cable connector: M3.5 Power circuit : 1.7 Nm Phillips screw driver No. 2 via cable connector Screw: M3.5 Control circuit: 1.7 Nm Screwdriver pozidriv No 2 for screw tightening Power circuit: 1.7 Nm Screwdriver pozidriv No 2 for screw tightening |
Power circuit: 1.7 Nm via screwdriver Ø 6 flat power circuit: 1.7 Nm via screwdriver No 2 Phillips screw control circuit: 1.7 Nm via screwdriver Ø 6 flat control circuit: 1.7 Nm via screw Screwdriver No. 2 for fastening Phillips screw Power circuit: 1.7 Nm Screwdriver Ø 6 flat-blade screw via cable connector: M3.5 Power circuit : 1.7 Nm Phillips screw driver No. 2 via cable connector Screw: M3.5 Control circuit: 1.7 Nm Screwdriver pozidriv No 2 for screw tightening Power circuit: 1.7 Nm Screwdriver pozidriv No 2 for screw tightening |
Power circuit: 1.7 Nm via screwdriver Ø 6 flat power circuit: 1.7 Nm via screwdriver No 2 Phillips screw control circuit: 1.7 Nm via screwdriver Ø 6 flat control circuit: 1.7 Nm via screw Screwdriver No. 2 for fastening Phillips screw Power circuit: 1.7 Nm Screwdriver Ø 6 flat-blade screw via cable connector: M3.5 Power circuit : 1.7 Nm Phillips screw driver No. 2 via cable connector Screw: M3.5 Control circuit: 1.7 Nm Screwdriver pozidriv No 2 for screw tightening Power circuit: 1.7 Nm Screwdriver pozidriv No 2 for screw tightening |
Auxiliary contact type | 1 NO + 1 NC | 1 NO + 1 NC | 1 NO + 1 NC |
Auxiliary contact type | Type Mechanical connection 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirrored with main contact status 1 NC conforming to IEC 60947-4-1 |
1 NO + 1 NC | 1 NO + 1 NC |
Signal loop frequency | 25…400Hz | 25…400Hz | 25…400Hz |
Minimum switching voltage | 17 V for signal return | 17 V for signal return | 17 V for signal return |
Minimum switching current [Imin] | 5 mA for signal loop | 5 mA for signal loop | 5 mA for signal loop |
Insulation resistance | > 10 MΩ for signal loops | > 10 MΩ for signal loops | > 10 MΩ for signal loops |
non-overlapping time | 1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts |
1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts |
1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts |
installation method | DIN rail installation base plate installation |
DIN rail installation base plate installation |
Chassis mounting rail installation |
environment | |||
standard | GB 14048.4 IEC 60947-4-1 |
IEC 60947-4-1 GB 14048.4 |
IEC 60947-4-1 GB 14048.4 |
certified product | CCC CE UKCA |
CCC CE UKCA |
CCC CE UKCA |
IP protection class | IP2x front panel for main circuits conforming to IEC 60529 IP2x front panel for coil circuits conforming to IEC 60529 |
IP2x front panel for main circuits conforming to IEC 60529 IP2x front panel for coil circuits conforming to IEC 60529 |
IP2x front panel for main circuits conforming to IEC 60529 IP2x front panel for coil circuits conforming to IEC 60529 |
Protective measures | TH conforms to IEC 60068-2-30 | TH conforms to IEC 60068-2-30 | TH conforms to IEC 60068-2-30 |
ambient air temperature | -40…60 °C operation 60…70 °C with derating -60…80 °C storage |
-40…60 °C operation 60…70 °C with derating -60…80 °C storage |
-40…60 °C operation 60…70 °C with derating -60…80 °C storage |
working altitude | 3000 m None | 3000 m None | 3000 m None |
Fire resistance and abnormal high temperature resistance | 850 °C conforming to IEC 60695-2-11 | 850 °C conforming to IEC 60695-2-11 | 850 °C conforming to IEC 60695-2-11 |
Shock and vibration resistance | Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed ( 4 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock performance 11 ms with contacts open (10 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27 |
Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed ( 4 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock performance 11 ms with contacts open (10 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27 |
Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed ( 4 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock performance 11 ms with contacts open (10 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27 |
high | 85 mm | 85 mm | 85 mm |
width | 45 mm | 45 mm | 45 mm |
depth | 92 mm | 92 mm | 92 mm |
Product Weight | 0.365 kg | 0.365 kg | 0.365 kg |
packaging unit | |||
Unit Type of Package 1 | PCE | PCE | PCE |
Number of Units in Package 1 | 1 | 1 | 1 |
Package 1 Height | 8.0cm | 8.0cm | 8.0cm |
Package 1 Width | 9.3 cm | 9.3 cm | 9.3 cm |
Package 1 Length | 5.2 cm | 5.2 cm | 5.2 cm |
Package 1 Weight | 381.48g | 381.48g | 394.86g |
Unit Type of Package 2 | CAR | CAR | CAR |
Number of Units in Package 2 | Twenty one | Twenty one | Twenty one |
Package 2 Height | 30.0cm | 30.0cm | 30.0cm |
Package 2 Width | 40.0cm | 40.0cm | 40.0cm |
Package 2 Length | 15.0cm | 15.0cm | 15.0cm |
Package 2 Weight | 8.061kg | 8.061kg | 8.342 kg |
Unit Type of Package 3 | PAL | PAL | PAL |
Number of Units in Package 3 | 336 | 336 | 336 |
Package 3 Height | 60.0cm | 60.0cm | 60.0cm |
Package 3 Width | 80.0cm | 80.0cm | 80.0cm |
Package 3 Length | 75.0cm | 75.0cm | 75.0cm |
Package 3 Weight | 128.376 kg | 128.376kg | 132.872kg |
contract warranty | |||
Warranty | 18 months | 18 months | 18 months |
Weight | N/A |
---|---|
Dimensions | N/A |
Related products
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details