TeSys – CAD – 3 Poles Control Loop Relays – Schneider Control Relays

$ 15.41$ 36.80

SKU: N/A

Specifications

Main
Part Number

CAD32B7C

CAD32BDC

CAD32E7C

CAD32F7C

Product Series TeSys
TeSys Deca
TeSys
TeSys Deca
TeSys
TeSys Deca
TeSys
TeSys Deca
product name TeSys CAD
TeSys Deca
TeSys CAD
TeSys Deca
TeSys CAD
TeSys Deca
TeSys CAD
TeSys Deca
product type Control relay Control relay Control relay Control relay
product short name CAD CAD CAD CAD
Application field of contactor Control loop Control loop Control loop Control loop
use category AC-14
AC-15
DC-13
AC-14
DC-13
AC-15
AC-15
DC-13
AC-14
AC-14
DC-13
AC-15
Loop contact type 3 NO + 2 NC 3 NO + 2 NC 3 NO + 2 NC 3 NO + 2 NC
Control circuit voltage 24 V AC 50/60 Hz 24 V DC 48 V AC 50/60 Hz 110V AC 50/60Hz
Additional information
Rated working voltage [Ue] <= 690 V AC 25…400 Hz <= 690 V AC 25…400 Hz <= 690 V AC 25…400 Hz <= 690 V AC 25…400 Hz
Mechanical life 30 Mcycles 30 Mcycles 30 Mcycles 30 Mcycles
operating frequency 180 times/min 180 times/min 180 times/min 180 times/min
action time 12…22 ms Coil energizes and NO contact closes
4…12 ms Coil discharges and NO opens
4…19 ms Coil energizes and NC contacts open
6…17 ms Coil deenergizes and NC closure
50…55 ms Coil energizes and NO contact closes
6…14 ms Coil discharges and NO opens
35…45 ms Coil energizes and NC contacts open
20 ms Coil deenergizes and NC closes
12…22 ms Coil energizes and NO contact closes
4…12 ms Coil discharges and NO opens
4…19 ms Coil energizes and NC contacts open
6…17 ms Coil deenergizes and NC closure
12…22 ms Coil energizes and NO contact closes
4…12 ms Coil discharges and NO opens
4…19 ms Coil energizes and NC contacts open
6…17 ms Coil deenergizes and NC closure
Control voltage limit Operation: 0.8…1.1 Uc Operation at 50 Hz
: 0.85…1.1 Uc
Release at 60 Hz: 0.3…0.6 Uc
Running: 0.7…1.25 Uc
Release: 0.1…0.25 Uc
Operation: 0.8…1.1 Uc Operation at 50 Hz
: 0.85…1.1 Uc
Release at 60 Hz: 0.3…0.6 Uc
Operation: 0.8…1.1 Uc Operation at 50 Hz
: 0.85…1.1 Uc
Release at 60 Hz: 0.3…0.6 Uc
(~50Hz hold) power consumption (VA) 8VA 50Hz 20°C) N/A 8VA 50Hz 20°C) 8VA 50Hz 20°C)
(~50Hz pickup) power consumption (VA) 70VA 50Hz 20°C) 70VA 50Hz 20°C) 70VA 50Hz 20°C)
Conventional thermal current [Ith] 10 A at <40 °C 10 A at <40 °C 10 A at <40 °C 10 A at <40 °C
Rated making capacity [Irms] 140 A AC conforming to IEC 60947-5-1
250 A DC conforming to IEC 60947-5-1
140 A AC conforming to IEC 60947-5-1
250 A DC conforming to IEC 60947-5-1
140 A AC conforming to IEC 60947-5-1
250 A DC conforming to IEC 60947-5-1
140 A AC conforming to IEC 60947-5-1
250 A DC conforming to IEC 60947-5-1
Rated short-time withstand current [Icw] 100 A – 1 s
120 A – 500 ms
140 A – 100 ms
100 A – 1 s
120 A – 500 ms
140 A – 100 ms
100 A – 1 s
120 A – 500 ms
140 A – 100 ms
100 A – 1 s
120 A – 500 ms
140 A – 100 ms
Fuses for use with relays 10 A gG conforming to IEC 60947-5-1 10 A gG conforming to IEC 60947-5-1 10 A gG conforming to IEC 60947-5-1 10 A gG conforming to IEC 60947-5-1
Rated insulation voltage [Ui] 690 V conforming to IEC 60947-5-1 690 V conforming to IEC 60947-5-1 690 V conforming to IEC 60947-5-1 690 V conforming to IEC 60947-5-1
Insulation resistance > 10 MΩ > 10 MΩ > 10 MΩ > 10 MΩ
Rated impulse withstand voltage [Uimp] 6 kV according to IEC 60947 6 kV according to IEC 60947 6 kV according to IEC 60947 6 kV according to IEC 60947
Minimum switching current [Imin] 5 mA 5 mA 5 mA 5 mA
Minimum switching capacity [U min] 17V 17V 17V 17V
non-overlapping time 1.5 ms between energized NC and NO contacts
1.5 ms between de-energized NC and NO contacts
1.5 ms between energized NC and NO contacts
1.5 ms between de-energized NC and NO contacts
1.5 ms between energized NC and NO contacts
1.5 ms between de-energized NC and NO contacts
1.5 ms between energized NC and NO contacts
1.5 ms between de-energized NC and NO contacts
installation method DIN rail installation
base plate installation
Chassis mounting
rail installation
Chassis mounting
rail installation
DIN rail installation
base plate installation
Wiring capacity Screw-on1
1…4 mm² Cable option: Flexible without cable terminal Screw-on2 1…4 mm² Cable option: Flexible without cable terminal Screw-on1
1…4 mm² Cable option: Flexible wire with screw terminal
2 1…2.5 mm² Cable selection: flexible wire with screw terminal
1 1…4 mm² Cable selection: solid wire without
screw terminal 2 1 …4 mm² Cable option: Solid without wire terminals
Screw-on1
1…4 mm² Cable option: Flexible without cable terminal Screw-on2 1…4 mm² Cable option: Flexible without cable terminal Screw-on1
1…4 mm² Cable option: Flexible wire with screw terminal
2 1…2.5 mm² Cable selection: flexible wire with screw terminal
1 1…4 mm² Cable selection: solid wire without
screw terminal 2 1 …4 mm² Cable option: Solid without wire terminals
Screw-on1
1…4 mm² Cable option: Flexible without cable terminal Screw-on2 1…4 mm² Cable option: Flexible without cable terminal Screw-on1
1…4 mm² Cable option: Flexible wire with screw terminal
2 1…2.5 mm² Cable selection: flexible wire with screw terminal
1 1…4 mm² Cable selection: solid wire without
screw terminal 2 1 …4 mm² Cable option: Solid without wire terminals
Screw-on1
1…4 mm² Cable option: Flexible without cable terminal Screw-on2 1…4 mm² Cable option: Flexible without cable terminal Screw-on1
1…4 mm² Cable option: Flexible wire with screw terminal
2 1…2.5 mm² Cable selection: flexible wire with screw terminal
1 1…4 mm² Cable selection: solid wire without
screw terminal 2 1 …4 mm² Cable option: Solid without wire terminals
Tightening torque 1.7 Nm tightened with bolts 1.7 Nm tightened with bolts 1.7 Nm tightened with bolts 1.7 Nm tightened with bolts
high 77 mm 77 mm 77 mm 77 mm
width 45 mm 45 mm 45 mm 45 mm
depth 84 mm 93 mm 84 mm 84 mm
Product Weight 580g 580g 580g 580g
environment
Standards compliant IEC 60947-5-1
GB 14048.5
GB 14048.5
IEC 60947-5-1
IEC 60947-5-1
GB 14048.5
IEC 60947-5-1
GB 14048.5
certified product CCC
CE
UKCA
CCC
CE
UKCA
CCC
CE
UKCA
CCC
CE
UKCA
quality mark CE declaration CE declaration CE declaration CE declaration
IP protection class IP2x front panel conforming to IEC 60529 IP2x front panel conforming to IEC 60529 IP2x front panel conforming to IEC 60529 IP2x front panel conforming to IEC 60529
Protective measures TH conforms to IEC 60068 TH conforms to IEC 60068 TH conforms to IEC 60068 TH conforms to IEC 60068
operating temperature -40…70°C -40…70°C -40…70°C -40…70°C
storage environment temperature -60…80°C -60…80°C -60…80°C -60…80°C
working altitude 3000m 3000m 3000m 3000m
Shock and vibration resistance Shock resistance 11 ms control relay open (10 gn) conforming to IEC 60068-2-27
Shock resistance 11 ms control relay closing (15 gn) conforming to IEC 60068-2-27
Shock resistance control relay open (2 gn (5.. .300 Hz)) according to IEC 60068-2-6
shock resistance control relay closed (4 gn (5…300 Hz)) according to IEC 60068-2-6
Shock resistance 11 ms control relay open (10 gn) conforming to IEC 60068-2-27
Shock resistance 11 ms control relay closing (15 gn) conforming to IEC 60068-2-27
Shock resistance control relay open (2 gn (5.. .300 Hz)) according to IEC 60068-2-6
shock resistance control relay closed (4 gn (5…300 Hz)) according to IEC 60068-2-6
Shock resistance 11 ms control relay open (10 gn) conforming to IEC 60068-2-27
Shock resistance 11 ms control relay closing (15 gn) conforming to IEC 60068-2-27
Shock resistance control relay open (2 gn (5.. .300 Hz)) according to IEC 60068-2-6
shock resistance control relay closed (4 gn (5…300 Hz)) according to IEC 60068-2-6
Shock resistance 11 ms control relay open (10 gn) conforming to IEC 60068-2-27
Shock resistance 11 ms control relay closing (15 gn) conforming to IEC 60068-2-27
Shock resistance control relay open (2 gn (5.. .300 Hz)) according to IEC 60068-2-6
shock resistance control relay closed (4 gn (5…300 Hz)) according to IEC 60068-2-6
packaging unit
Unit Type of Package 1 PCE PCE PCE PCE
Number of Units in Package 1 1 1 1 1
Package 1 Height 5.185 cm 5.12cm 5.24cm 5.8cm
Package 1 Width 7.895 cm 7.754 cm 7.77cm 8.3 cm
Package 1 Length 9.453 cm 10.091 cm 9.28cm 9.6cm
Package 1 Weight 350.0g 522g 355.0g 356.0g
Unit Type of Package 2 S02 CAR S02 S02
Number of Units in Package 2 Twenty four Twenty one Twenty four Twenty four
Package 2 Height 15cm 30cm 15cm 15cm
Package 2 Width 30cm 40cm 30cm 30cm
Package 2 Length 40cm 15cm 40cm 40cm
Package 2 Weight 8.91kg 11410g 8.95kg 8.873kg
Unit Type of Package 3 PAL PAL PAL PAL
Number of Units in Package 3 384 336 384 384
Package 3 Height 60cm 60cm 60cm 60cm
Package 3 Width 80.0cm 80cm 80cm 80cm
Package 3 Length 75cm 75cm 75cm 75cm
Package 3 Weight 144.448kg 182560g 137.836kg 145.344kg
contract warranty
Warranty 18 months 18 months 18 months 18 months

 

Main
Part Number

CAD32FD

CAD32FDC

CAD32M7C

CAD32MDC

Product Series TeSys
TeSys Deca
TeSys
TeSys Deca
TeSys
TeSys Deca
TeSys
TeSys Deca
product name TeSys CAD TeSys CAD
TeSys Deca
TeSys CAD
TeSys Deca
TeSys CAD
TeSys Deca
product type Control relay Control relay Control relay Control relay
product short name CAD CAD CAD CAD
Application field of contactor Control loop Control loop Control loop Control loop
Additional information
use category AC-15
DC-13
AC-14
DC-13
AC-14
AC-15
AC-14
AC-15
DC-13
AC-15
AC-14
DC-13
Loop contact type 3 NO + 2 NC 3 NO + 2 NC 3 NO + 2 NC 3 NO + 2 NC
Rated working voltage [Ue] <= 690 V AC 25…400 Hz <= 690 V AC 25…400 Hz <= 690 V AC 25…400 Hz <= 690 V AC 25…400 Hz
Control loop characteristics DC standard N/A
Control circuit voltage 110VDC 110VDC 230V AC 50/60Hz 230V DC
Rated impulse withstand voltage [Uimp] 6 kV according to IEC 60947 6 kV according to IEC 60947 6 kV according to IEC 60947 6 kV according to IEC 60947
Conventional thermal current [Ith] 10 A at <60 °C 10 A at <40 °C 10 A at <40 °C 10 A at <40 °C
Rated making capacity [Irms] 140 A AC conforming to IEC 60947-5-1
250 A DC conforming to IEC 60947-5-1
140 A AC conforming to IEC 60947-5-1
250 A DC conforming to IEC 60947-5-1
140 A AC conforming to IEC 60947-5-1
250 A DC conforming to IEC 60947-5-1
140 A AC conforming to IEC 60947-5-1
250 A DC conforming to IEC 60947-5-1
Rated short-time withstand current [Icw] 100 A – 1 s
120 A – 500 ms
140 A – 100 ms
100 A – 1 s
120 A – 500 ms
140 A – 100 ms
100 A – 1 s
120 A – 500 ms
140 A – 100 ms
100 A – 1 s
120 A – 500 ms
140 A – 100 ms
Fuses for use with relays 10 A gG conforming to IEC 60947-5-1 10 A gG conforming to IEC 60947-5-1 10 A gG conforming to IEC 60947-5-1 10 A gG conforming to IEC 60947-5-1
Rated insulation voltage [Ui] 600 V UL Listed
600 V CSA Listed
690 V Conforms to IEC 60947-5-1
690 V conforming to IEC 60947-5-1 690 V conforming to IEC 60947-5-1 690 V conforming to IEC 60947-5-1
installation method DIN rail installation
base plate installation
Chassis mounting
rail installation
Chassis mounting
rail installation
DIN rail installation
base plate installation
Wiring capacity Bolt fastening1 Cable 1…4 mm² flexible without
bolt fastening2 Cable 1…4 mm² flexible without
bolt fastening1 Cable 1…4 mm² flexible with
bolt fastening2 Cable 1…2.5 mm² flexible with bolt fastening
Screw fastening1 cable 1…4 mm² solid without
screw fastening2 cable 1…4 mm² solid without screw fastening
Screw-on1
1…4 mm² Cable option: Flexible without cable terminal Screw-on2 1…4 mm² Cable option: Flexible without cable terminal Screw-on1
1…4 mm² Cable option: Flexible wire with screw terminal
2 1…2.5 mm² Cable selection: flexible wire with screw terminal
1 1…4 mm² Cable selection: solid wire without
screw terminal 2 1 …4 mm² Cable option: Solid without wire terminals
Screw-on1
1…4 mm² Cable option: Flexible without cable terminal Screw-on2 1…4 mm² Cable option: Flexible without cable terminal Screw-on1
1…4 mm² Cable option: Flexible wire with screw terminal
2 1…2.5 mm² Cable selection: flexible wire with screw terminal
1 1…4 mm² Cable selection: solid wire without
screw terminal 2 1 …4 mm² Cable option: Solid without wire terminals
Screw-on1
1…4 mm² Cable option: Flexible without cable terminal Screw-on2 1…4 mm² Cable option: Flexible without cable terminal Screw-on1
1…4 mm² Cable option: Flexible wire with screw terminal
2 1…2.5 mm² Cable selection: flexible wire with screw terminal
1 1…4 mm² Cable selection: solid wire without
screw terminal 2 1 …4 mm² Cable option: Solid without wire terminals
Tightening torque 1.2 Nm Screwdriver No. 2 for screw tightening Phillips screw
1.2 Nm Screwdriver Ø 6 for screw tightening Flat
1.2 Nm Screwdriver pozidriv No. 2 for screw tightening
1.7 Nm tightened with bolts 1.7 Nm tightened with bolts 1.7 Nm tightened with bolts
Control voltage limit 0.1…0.25 Uc -40…70 °C release DC
0.7…1.25 Uc -40…60 °C run DC
1…1.25 Uc 60…70 °C run DC
Running: 0.7…1.25 Uc
Release: 0.1…0.25 Uc
Operation: 0.8…1.1 Uc Operation at 50 Hz
: 0.85…1.1 Uc
Release at 60 Hz: 0.3…0.6 Uc
Running: 0.7…1.25 Uc
Release: 0.1…0.25 Uc
action time 53…72 ms coil energization and NO contact closure
16…24 ms coil discharge and NO opening
47…63 ms coil energization and NC contact opening
15…25 ms coil de-energization and NC closure
50…55 ms Coil energizes and NO contact closes
6…14 ms Coil discharges and NO opens
35…45 ms Coil energizes and NC contacts open
20 ms Coil deenergizes and NC closes
12…22 ms Coil energizes and NO contact closes
4…12 ms Coil discharges and NO opens
4…19 ms Coil energizes and NC contacts open
6…17 ms Coil deenergizes and NC closure
50…55 ms Coil energizes and NO contact closes
6…14 ms Coil discharges and NO opens
35…45 ms Coil energizes and NC contacts open
20 ms Coil deenergizes and NC closes
Mechanical life 30 Mcycles 30 Mcycles 30 Mcycles 30 Mcycles
operating frequency 180 times/min 180 times/min 180 times/min 180 times/min
time constant 28ms N/A
Surge power (W) 5.4W (20°C)
Holding power consumption(W) 5.4 W at 20 °C
Minimum switching voltage 17V
Minimum switching current [Imin] 5 mA 5 mA 5 mA 5 mA
non-overlapping time 1.5 ms between energized NC and NO contacts
1.5 ms between de-energized NC and NO contacts
1.5 ms between energized NC and NO contacts
1.5 ms between de-energized NC and NO contacts
1.5 ms between energized NC and NO contacts
1.5 ms between de-energized NC and NO contacts
1.5 ms between energized NC and NO contacts
1.5 ms between de-energized NC and NO contacts
Insulation resistance > 10 MΩ > 10 MΩ > 10 MΩ > 10 MΩ
Shock and vibration resistance Shock resistance control relay open: 10 gn (11ms) according to IEC 60068-2-27
Shock resistance control relay closed: 15 gn (11ms) according to IEC 60068-2-27
shock resistance control relay open: 2 gn (5.. .300 Hz) conforming to IEC 60068-2-6
Shock resistance Control relay closed: 4 gn (5…300 Hz) conforming to IEC 60068-2-6
Shock resistance 11 ms control relay open (10 gn) conforming to IEC 60068-2-27
Shock resistance 11 ms control relay closing (15 gn) conforming to IEC 60068-2-27
Shock resistance control relay open (2 gn (5.. .300 Hz)) according to IEC 60068-2-6
shock resistance control relay closed (4 gn (5…300 Hz)) according to IEC 60068-2-6
Shock resistance 11 ms control relay open (10 gn) conforming to IEC 60068-2-27
Shock resistance 11 ms control relay closing (15 gn) conforming to IEC 60068-2-27
Shock resistance control relay open (2 gn (5.. .300 Hz)) according to IEC 60068-2-6
shock resistance control relay closed (4 gn (5…300 Hz)) according to IEC 60068-2-6
Shock resistance 11 ms control relay open (10 gn) conforming to IEC 60068-2-27
Shock resistance 11 ms control relay closing (15 gn) conforming to IEC 60068-2-27
Shock resistance control relay open (2 gn (5.. .300 Hz)) according to IEC 60068-2-6
shock resistance control relay closed (4 gn (5…300 Hz)) according to IEC 60068-2-6
high 77 mm 77 mm 77 mm 77 mm
width 45 mm 45 mm 45 mm 45 mm
depth 93 mm 93 mm 84mm 93 mm
Product Weight 0.58 kg 580g 580g 580g
environment
standard BS 4794
EN 60947-5
IEC 60947-5-1
NF C 63-140
VDE 0660
IEC 60335-1
N/A
certified product CSA
UL
UKCA
CCC
CE
UKCA
CCC
CE
UKCA
CCC
CE
UKCA
IP protection class IP2x front panel according to VDE 0106 IP2x front panel conforming to IEC 60529 IP2x front panel conforming to IEC 60529 IP2x front panel conforming to IEC 60529
Protective measures TH conforms to IEC 60068 TH conforms to IEC 60068 TH conforms to IEC 60068 TH conforms to IEC 60068
ambient temperature -40…60 °C
60…70 °C with derating
N/A
storage environment temperature -60…80°C -60…80°C -60…80°C -60…80°C
working altitude 0…3000m 3000m 3000m 3000m
packaging unit
Unit Type of Package 1 PCE PCE PCE PCE
Number of Units in Package 1 1 1 1 1
Package 1 Height 5cm 5.9cm 4.98cm 5.381 cm
Package 1 Width 9.2 cm 8.0cm 7.95cm 8.016 cm
Package 1 Length 11.2 cm 10.7cm 9.22cm 10.37cm
Package 1 Weight 515g 519.0g 360.61g 480.0g
Unit Type of Package 2 S02 S02 S02 S02
Number of Units in Package 2 15 Twenty one Twenty four Twenty one
Package 2 Height 15cm 15.0cm 15.0cm 15.0cm
Package 2 Width 30cm 30.0cm 30.0cm 30.0cm
Package 2 Length 40cm 40.0cm 40.0cm 40.0cm
Package 2 Weight 8.255 kg 11.306kg 8.785 kg 10.761kg
Unit Type of Package 3 P06 PAL PAL PAL
Number of Units in Package 3 120 336 384 336
Package 3 Height 77cm 60.0cm 60.0cm 60.0cm
Package 3 Width 80cm 80.0cm 80.0cm 80.0cm
Package 3 Length 60cm 75.0cm 75.0cm 75.0cm
Package 3 Weight 74.66 kg 180.352kg 140.627 kg 178.895kg
contract warranty
Warranty 18 months 18 months 18 months 18 months

 

Weight N/A
Dimensions N/A