SPAU-P10R-MS6-F-L-PNLK-PNVBA-M12D – Festo Pressure Sensors And Vacuum Sensors
USD $ 187.74 USD $ 153.95
SKU: Festo 8074906
Manufacturer Part Number: Festo 8074906
Festo Pressure Sensors And Vacuum Sensors: SPAU-P10R-MS6-F-L-PNLK-PNVBA-M12D
OEM Spec Ref
The Festo SPAU-P10R-MS6-F-L-PNLK-PNVBA-M12D, MPN 8074906, represents the pinnacle of precision in pressure and vacuum sensing technology, tailored for diverse industrial applications. Designed for reliability, this sensor ensures optimal performance in monitoring and controlling pressure levels within pneumatic systems. Its compact design, featuring a robust M12 connector, makes it suitable for tight installations where space is at a premium.
Key Features:
- Precision Measurement: Offers accurate pressure and vacuum readings, essential for maintaining the efficacy of industrial processes.
- User-Friendly Interface: Equipped with an intuitive display for easy monitoring and configuration, enhancing operational efficiency.
- Versatile Application: Ideal for a wide range of industries, including automotive, pharmaceutical, and food processing, where precise pressure control is critical.
- Durable Construction: Engineered with high-quality materials to withstand harsh industrial environments, ensuring long-term reliability.
- Easy Integration: The M12 connector facilitates straightforward integration into existing pneumatic systems, promoting seamless operation.
Benefits:
- Operational Excellence: Enhances system performance through accurate pressure regulation, contributing to improved product quality and consistency.
- Cost Efficiency: Helps in reducing energy consumption and minimizing wear and tear on machinery, leading to significant cost savings.
- Safety and Compliance: Assists in adhering to industry safety standards by providing reliable monitoring, ensuring a safer working environment.
Applications:
- Process Automation: Optimizes process efficiency in manufacturing lines, ensuring products meet stringent quality standards.
- Environmental Monitoring: Monitors air quality and ventilation systems, crucial for maintaining healthy workplace conditions.
- Machine Tool Operation: Enhances the precision of CNC machines, resulting in superior craftsmanship and product integrity.
Technical Data
Feature | Specification |
---|---|
Symbol | 995410 |
Certification | RCM compliance mark c UL us – Listed (OL) |
CE marking (see declaration of conformity) | As per EU EMC directive As per EU RoHS directive |
UKCA marking (see declaration of conformity) | To UK instructions for EMC To UK RoHS instructions |
KC characters | KC EMC |
Note on materials | RoHS-compliant |
Measured variable | Relative pressure |
Method of measurement | Piezoresistive pressure sensor |
Pressure measuring range initial value | 0 Mpa |
Pressure measuring range initial value | 0 bar |
Pressure measuring range initial value | 0 psi |
Pressure measuring range end value | 1 Mpa |
Pressure measuring range end value | 10 bar |
Pressure measuring range end value | 145 psi |
Max. overload pressure | 15 bar |
Overload pressure | 1.5 Mpa |
Overload pressure | 15 bar |
Overload pressure | 217.5 psi |
Operating medium | Compressed air as per ISO 8573-1:2010 [7:4:4] Inert gas |
Information on operating and pilot media | Operation with oil lubrication possible |
Temperature of medium | 0 °C … 50 °C |
Ambient temperature | 0 °C … 50 °C |
ADC resolution | 12 bit |
Accuracy in ± % FS | 1.5 %FS |
Repetition accuracy in ± %FS | 0.3 %FS |
Temperature co-efficient in ± %FS/K | 0.05 %FS/K |
Switching output | 2 x PNP or 2 x NPN switchable |
Switching function | Freely programmable |
Switching element function | N/C contact/N/O contact switchable |
Max. output current | 100 mA |
Analog output | 0 – 10 V 4 – 20 mA 1 – 5 V |
Rise time | 3 ms |
Max. load resistance of current output | 500 Ohm |
Min. load resistance of voltage output | 10 kOhm |
Short-circuit protection | yes |
Protocol | IO-Link® |
IO-Link®, protocol version | Device V 1.1 |
IO-Link®, profile | Smart sensor profile |
IO-Link®, function classes | Binary data channel (BDC) Process data variable (PDV) Identification Diagnostics Teach channel |
IO-Link®, communication mode | COM2 (38,4 kBd) |
IO-Link®, SIO mode support | Yes |
IO-Link®, port class | A |
IO-Link®, process data width OUT | 0 Byte |
IO-Link®, process data width IN | 2 Byte |
IO-Link®, process data content IN | 14 bit PDV (pressure measurement) 2 bit BDC (pressure monitoring) |
IO-Link®, minimum cycle time | 3 ms |
IO-Link®, data memory required | 500 byte |
DC operating voltage range | 20 V … 30 V |
Reverse polarity protection | for all electrical connections |
Electrical connection 1, connection type | Plug |
Electrical connection 1, connection technology | M12x1 A-coded as per EN 61076-2-101 |
Electrical connection 1, number of pins/wires | 4 |
Electrical connection for input 1, connection pattern | 00995386 |
Type of mounting | On service unit |
Mounting positionAny | Any |
Pneumatic connection | Flange |
Product weight | 80g |
Display type | Illuminated LCD |
Displayable unit(s) | MPa bar inH2O inHg kPa kgf/cm² mmHg psi |
Setting options | IO-Link® Teach-in Via display and pushbuttons |
Protection against tampering | IO-Link® PIN code |
Setting range threshold value | 0 % … 100 % |
Setting range hysteresis | 0 % … 90 % |
Degree of protection | IP65 |
Corrosion resistance class (CRC) | 2 – Moderate corrosion stress |
LABS (PWIS) conformity | VDMA24364-B1/B2-L |
Weight | 0.080 kg |
---|