$ 295.55
input | |
type of the power supply network | 1-phase and 2-phase AC |
supply voltage at AC | Set by means of selector switch on the device |
supply voltage 1 at AC | 120 … 230 V |
supply voltage 2 at AC | 230 … 500 V |
input voltage 1 at AC | 85 … 264 V |
input voltage 2 at AC | 176 … 550 V |
wide range input | Yes |
overvoltage overload capability | 1300 Vpeak, 1.3 ms |
buffering time for rated value of the output current in the event of power failure minimum |
25 ms |
operating condition of the mains buffering | at Vin = 120/230 V, typ. 150 ms at Vin = 400 V |
line frequency | 50/60 Hz |
line frequency | 47 … 63 Hz |
input current | |
● at rated input voltage 120 V | 4.4 A |
● at rated input voltage 230 V | 2.4 A |
● at rated input voltage 500 V | 1.1 A |
current limitation of inrush current at 25 °C maximum | 35 A |
I2t value maximum | 4 A²·s |
fuse protection type | T 6.3 A (not accessible) |
fuse protection type in the feeder | Recommended miniature circuit breaker at 1-phase operation: from 6 A (10 A) characteristic C (B); required at 2-phase operation: circuit breaker 2-pole connected or circuit breaker 3RV2011-1EA10 (setting 3.8 A) or 3RV2711- 1ED10 (UL 489) at 230 V; 3RV2011-1DA10 (setting 3 A) or 3RV2711-1DD10 (UL 489) at 400/500 V |
output | |
voltage curve at output | Controlled, isolated DC voltage |
output voltage at DC rated value | 24 V |
output voltage | |
● at output 1 at DC rated value | 24 V |
output voltage adjustable | Yes; via potentiometer |
adjustable output voltage | 24 … 28.8 V |
relative overall tolerance of the voltage | 3 % |
relative control precision of the output voltage | |
● on slow fluctuation of input voltage | 0.1 % |
● on slow fluctuation of ohm loading | 0.1 % |
residual ripple | |
● maximum | 50 mV |
voltage peak | |
● maximum | 200 mV |
display version for normal operation | Green LED for 24 V OK |
type of signal at output | relay contact (normally open, contact rating (SELV (ES1) must be observed): 30 V DC/0.1 A |
behavior of the output voltage when switching on | Overshoot of Vout approx. 3 % |
response delay maximum | 1 s |
voltage increase time of the output voltage | |
● typical | 50 ms |
output current | |
● rated value | 10 A |
● rated range | 0 … 10 A; +60 … +70 °C: Derating 2%/K (at 120 V, 230 V) or 3.5%/K (at 400 V) |
supplied active power typical | 240 W |
short-term overload current | |
● at short-circuit during operation typical | 30 A |
duration of overloading capability for excess current | |
● at short-circuit during operation | 25 ms |
constant overload current | |
● on short-circuiting during the start-up typical | 12 A |
bridging of equipment | Yes; switchable characteristic |
number of parallel-switched equipment resources for increasing the power |
2 |
efficiency | |
efficiency in percent | 91 % |
power loss [W] | |
● at rated output voltage for rated value of the output current typical |
24 W |
● during no-load operation maximum | 6 W |
closed-loop control | |
relative control precision of the output voltage with rapid fluctuation of the input voltage by +/- 15% typical |
0.1 % |
relative control precision of the output voltage load step of resistive load 50/100/50 % typical |
3 % |
setting time | |
● load step 50 to 100% typical | 2 ms |
● load step 100 to 50% typical | 2 ms |
setting time | |
● maximum | 5 ms |
protection and monitoring | |
design of the overvoltage protection | < 35 V |
property of the output short-circuit proof | Yes |
design of short-circuit protection | Alternatively, constant current characteristic approx. 12 A or latching shutdown |
● typical | 12 A |
enduring short circuit current RMS value | |
● typical | 12 A |
display version for overload and short circuit | LED yellow for “overload”, LED red for “latching shutdown” |
safety | |
galvanic isolation between input and output | Yes |
galvanic isolation | Safety extra-low output voltage Uout acc. to EN 60950-1 and EN 50178 |
operating resource protection class | Class I |
leakage current | |
● maximum | 3.5 mA |
● typical | 0.32 mA |
protection class IP | IP20 |
EMC | |
standard | |
● for emitted interference | EN 55022 Class B |
● for mains harmonics limitation | EN 61000-3-2 |
● for interference immunity | EN 61000-6-2 |
standards, specifications, approvals | |
certificate of suitability | |
● CE marking | Yes |
● UL approval | Yes; cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259; cCSAus (CSA C22.2 No. 60950-1, UL 60950-1) |
● CSA approval | Yes; cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259; cCSAus (CSA C22.2 No. 60950-1, UL 60950-1) |
● UKCA marking | Yes |
● EAC approval | Yes |
● Regulatory Compliance Mark (RCM) | Yes |
● NEC Class 2 | No |
● SEMI F47 | Yes |
type of certification | |
● CB-certificate | Yes |
MTBF at 40 °C | 1 055 408 h |
standards, specifications, approvals hazardous environments | |
certificate of suitability | |
● IECEx | No |
● ATEX | No |
● ULhazloc approval | No |
● cCSAus, Class 1, Division 2 | No |
● FM registration | No |
standards, specifications, approvals marine classification | |
shipbuilding approval | Yes |
Marine classification association | |
● American Bureau of Shipping Europe Ltd. (ABS) | Yes |
● French marine classification society (BV) | No |
● Det Norske Veritas (DNV) | Yes |
● Lloyds Register of Shipping (LRS) | No |
standards, specifications, approvals Environmental Product Declaration | |
Environmental Product Declaration | Yes |
global warming potential [CO2 eq] | |
● total | 763.9 kg |
● during manufacturing | 12.6 kg |
● during operation | 751 kg |
● after end of life | 0.18 kg |
ambient conditions | |
ambient temperature | |
● during operation | -25 … +70; With natural convection; startup tested starting from -40 °C nominal voltage |
● during transport | -40 … +85 |
● during storage | -40 … +85 |
environmental category according to IEC 60721 | Climate class 3K3, 5 … 95% no condensation |
connection method | |
type of electrical connection | screw terminal |
● at input | L, N, PE: 1 screw terminal each for 0.2 … 2.5 mm² single-core/finely stranded |
● at output | +, -: 2 screw terminals each for 0.2 … 2.5 mm² |
● for auxiliary contacts | 13, 14 (alarm signal): 1 screw terminal each for 0.14 … 1.5 mm² |
mechanical data | |
width × height × depth of the enclosure | 70 × 125 × 121 mm |
installation width × mounting height | 70 mm × 225 mm |
required spacing | |
● top | 50 mm |
● bottom | 50 mm |
● left | 0 mm |
● right | 0 mm |
fastening method | Snaps onto DIN rail EN 60715 35×7.5/15 |
● DIN-rail mounting | Yes |
● S7 rail mounting | No |
● wall mounting | No |
housing can be lined up | Yes |
net weight | 0.8 kg |
accessories | |
electrical accessories | Buffer module |
Weight | 0.800 kg |
---|---|
Dimensions | 16 × 17 × 10 cm |
INOSAKI Limited
RM B 5/F Gaylord Comm,
Bldg 114-118 Lockhart Rd.
Hong Kong
INOSAKI Sdn. Bhd.
2-1-9, Ground Floor, One Square, Tingkat Mahsuri 1,
11900 Bayan Lepas, Penang
INOSAKI Pte. Ltd.
101 Upper Cross Street,
No. 06-17, People’s Park Centre,