Fail-safe digital input modules are suitable for connecting
The modules are implemented centrally with SIMATIC S7-31xF-2 DP, and in the ET 200M distributed I/O module in combination with SIMATIC IM 151-7 F-CPU, S7-31xF-2 DP, S7-416F-2 and S7-400F/FH. They can also be used in non-safety-relevant standard mode. In this case, they behave like standard S7-300 modules.
Article number | 6ES7326-1BK02-0AB0 |
SM326, F-DI 24 X DC24V, failsafe | |
Supply voltage | |
Rated value (DC) | 24 V |
Reverse polarity protection | Yes |
Input current | |
from load voltage L+ (without load), max. | 450 mA |
from backplane bus 5 V DC, max. | 100 mA |
Encoder supply | |
Number of outputs | 4; Isolated |
Type of output voltage | |
Output current | |
● Rated value | 400 mA |
Power loss | |
Power loss, typ. | 10 W |
Digital inputs | |
Number of digital inputs | 24 |
Number of simultaneously controllable inputs | |
all mounting positions | |
— up to 40 °C, max. | 24 |
— up to 60 °C, max. | 24; (at 24 V) or 18 (at 28.8 V) |
Input voltage | |
● Type of input voltage | DC |
● Rated value (DC) | 24 V |
● for signal “0” | -30 to +5 V |
● for signal “1” | +11 to +30V |
Input current | |
● for signal “0”, max. (permissible quiescent current) | 2 mA |
● for signal “1”, typ. | 10 mA |
Input delay (for rated value of input voltage) | |
for standard inputs | |
— at “0” to “1”, max. | 3.4 ms |
— at “1” to “0”, max. | 3.4 ms |
for NAMUR inputs | |
— at “0” to “1”, max. | |
— at “1” to “0”, max. | |
Cable length | |
● shielded, max. | 200 m |
● unshielded, max. | 100 m |
Encoder | |
Connectable encoders | |
● 2-wire sensor | Yes; if short-circuit test is deactivated |
— permissible quiescent current (2-wire sensor), max. | 2 mA |
Interrupts/diagnostics/status information | |
Diagnostics function | Yes |
Alarms | |
● Diagnostic alarm | Yes |
Diagnoses | |
● Diagnostic information readable | Yes |
Diagnostics indication LED | |
● Fail-safe operation | Yes |
● Group error SF (red) | Yes |
Ex(i) characteristics | |
Module for Ex(i) protection | |
maximum values for connecting terminals for gas group IIC | |
● Uo (no-load voltage), max. | |
● Io (short-circuit current), max. | |
● Po (power output), max. | |
● Co (permissible external capacity), max. | |
● Lo (permissible external inductivity), max. | |
● Um (voltage at non-intrinsically safe connecting terminals), max. | |
Potential separation | |
Potential separation digital inputs | |
● between the channels | Yes |
● between the channels, in groups of | 12 |
● between the channels and backplane bus | Yes |
● between the channels and the power supply of the electronics | |
Isolation | |
Isolation tested with | 500 V DC/350 V AC |
Standards, approvals, certificates | |
Highest safety class achievable in safety mode | |
● acc. to DIN VDE 0801 | AK 6 |
● acc. to EN 954 | Cat. 4 |
● Performance level according to ISO 13849-1 | e |
● SIL acc. to IEC 61508 | SIL 3 |
Use in hazardous areas | |
● ATEX certificate | |
Ambient conditions | |
Ambient temperature during operation | |
● max. | |
connection method / header | |
required front connector | 40-pin |
Dimensions | |
Width | 80 mm |
Height | 125 mm |
Depth | 120 mm |
Weights | |
Weight, approx. | 442 g |
Weight | 0.49 kg |
---|---|
Dimensions | 13.1 × 15.4 × 8.9 cm |