Even in the lower performance range, the FM 352 offers a cost-effective alternative cam controllers.

The FM 352 can be used:

  • On conveyor belts;
    the FM 352 captures the positions of parts via light barriers and then initiates actions (e.g., drilling, milling, applying adhesive) via setpoint-dependent setting of outputs
  • For press automation (metal, powder, glass).

Siemens Function Modules SIMATIC S7-300 Product Specifications:

Article number 6ES7352-1AH02-0AE0
FM352 Electron. Cam-operated Control
Supply voltage
Rated value (DC) 24 V
Input current
from load voltage L+ (without load), max. 200 mA
from backplane bus 5 V DC, max. 100 mA
Encoder supply
5 V encoder supply
● 5 V Yes
● Output current, max. 300 mA
● Cable length, max. 32 m
24 V encoder supply
● 24 V Yes
● Output current, max. 300 mA
● Cable length, max. 100 m
Power loss
Power loss, typ. 8.1 W
Digital inputs
Number of digital inputs 4
Functions Reference point switch, set floating actual value/length measurement, brake release, enable track output no. 3
Input voltage
● Rated value (DC) 24 V
● for signal “0” -30 to +5 V
● for signal “1” +11 to +30V
Input current
● for signal “0”, max. (permissible quiescent current) 2 mA
● for signal “1”, typ. 9 mA
Digital outputs
Number of digital outputs 13
Functions Cam track
Short-circuit protection Yes
Output voltage
● Rated value (DC) 24 V
● for signal “1”, min. UP – 0.8 V
Output current
● for signal “1” permissible range for 0 to 60 °C, min. 5 mA; with UPmax
● for signal “1” permissible range for 0 to 60 °C, max. 600 mA; with UPmax
● for signal “0” residual current, max. 0.5 mA
Encoder
Connectable encoders
● Incremental encoder (symmetrical) Yes
● Incremental encoder (asymmetrical) Yes
● Absolute encoder (SSI) Yes
● 2-wire sensor Yes
— permissible quiescent current (2-wire sensor), max. 2 mA
Encoder signals, incremental encoder (symmetrical)
● Trace mark signals A, notA, B, notB
● Zero mark signal N, notN
● Input voltage 5 V difference signal (phys. RS 422)
● Input frequency, max. 1 MHz
Encoder signals, incremental encoder (asymmetrical)
● Trace mark signals A, B
● Zero mark signal N
● Input voltage 24 V
● Input frequency, max. 50 kHz; 50 kHz for 25 m cable length; 25 kHz for 100 m cable length
Encoder signals, absolute encoder (SSI)
● Data signal DATA, notDATA
● Clock signal CL, notCL
● Telegram length, parameterizable 13 or 25 bit
● Clock frequency, max. 1 MHz
● Gray code Yes
● Cable length, shielded, max. 320 m; at max. 125 kHz
Potential separation
Potential separation digital inputs
● Potential separation digital inputs No
Potential separation digital outputs
● Potential separation digital outputs No
Ambient conditions
Ambient temperature during operation
● min. 0 °C
● max. 60 °C
Ambient temperature during storage/transportation
● min. -40 °C
● max. 70 °C
connection method / header
required front connector 1x 20-pin
Dimensions
Width 80 mm
Height 125 mm
Depth 120 mm
Weights
Weight, approx. 550 g
Weight 0.464 kg