SIMATIC ET 200eco PN – Digital I/O Devices – Siemens I/O Devices
$ 154.92 – $ 557.03
SKU: N/A
Digital inputs record 24 V DC signals in the plant and forward them to the controller. Switches and 2, 3 or 4-wire proximity switches can be connected.
Digital outputs switch 24 V DC voltages in the plant, thus transferring internal signals from the controller to the plant. Solenoid valves, DC contactors, and indicator lights can be connected.
The 30 mm and 45 mm wide I/O devices are especially suitable for use in extremely confined spaces. All I/O devices have configurable parameters and diagnostic functions and can thus be freely adapted to the respective process requirements.
Siemens Digital I/O Devices SIMATIC ET 200eco PN Product Specifications:
Article number | 6ES7141-6BF00-0AB0 | 6ES7141-6BG00-0AB0 | 6ES7141-6BH00-0AB0 |
ET200eco PN, 8DI, DC24V, 4xM12 | ET200eco PN, 8DI, DC24V, 8xM12 | ET200eco PN, 16DI, DC24V, 8xM12 | |
General information | |||
Vendor identification (VendorID) | 002AH | 002AH | 002AH |
Device identifier (DeviceID) | 0306H | 0306H | 0306H |
Supply voltage | |||
Rated value (DC) | 24 V | 24 V | 24 V |
Reverse polarity protection | Yes | Yes | Yes |
power supply according to NEC Class 2 required | Yes | Yes | Yes |
Input current | |||
Current consumption, typ. | 100 mA | 100 mA | 100 mA |
from supply voltage 1L+, max. | 4 A | 4 A | 4 A |
Encoder supply | |||
Number of outputs | 4 | 8 | 8 |
24 V encoder supply | |||
● Short-circuit protection | Yes; Electronic | Yes; Electronic | Yes; Electronic |
● Output current, max. | 100 mA; per output | 100 mA; per output | 100 mA; per output |
Power loss | |||
Power loss, typ. | 5.5 W | 4.5 W | 6.5 W |
Digital inputs | |||
Number of digital inputs | 8 | 8 | 16 |
● in groups of | 2 | 1 | 2 |
Input characteristic curve in accordance with IEC 61131, type 3 | Yes | Yes | Yes |
Number of simultaneously controllable inputs | |||
all mounting positions | |||
— up to 60 °C, max. | 8 | 8 | 16 |
Input voltage | |||
● Rated value (DC) | 24 V | 24 V | 24 V |
● for signal “0” | -3 to +5V | -3 to +5V | -3 to +5V |
● for signal “1” | +11 to +30V | +11 to +30V | +11 to +30V |
Input current | |||
● for signal “1”, typ. | 7 mA | 7 mA | 7 mA |
Input delay (for rated value of input voltage) | |||
for standard inputs | |||
— at “0” to “1”, max. | typically 3 ms | typically 3 ms | typically 3 ms |
— at “1” to “0”, max. | typically 3 ms | typically 3 ms | typically 3 ms |
Cable length | |||
● unshielded, max. | 30 m | 30 m | 30 m |
Encoder | |||
Connectable encoders | |||
● 2-wire sensor | Yes | Yes | Yes |
— permissible quiescent current (2-wire sensor), max. | 1.5 mA | 1.5 mA | 1.5 mA |
Interfaces | |||
Transmission procedure | 100BASE-TX | 100BASE-TX | 100BASE-TX |
Number of PROFINET interfaces | 1 | 1 | 1 |
1. Interface | |||
Interface types | |||
● M12 port | Yes | Yes | Yes |
● integrated switch | Yes | Yes | Yes |
Interface types | |||
M12 port | |||
● Autonegotiation | Yes | Yes | Yes |
● Autocrossing | Yes | Yes | Yes |
● Transmission rate, max. | 100 Mbit/s | 100 Mbit/s | 100 Mbit/s |
Protocols | |||
Supports protocol for PROFINET IO | Yes | Yes | Yes |
PROFINET CBA | No | No | No |
PROFIsafe | No | No | No |
PROFINET IO Device | |||
Services | |||
— IRT with the option “high flexibility” | Yes | Yes | Yes |
— Prioritized startup | Yes | Yes | Yes |
Redundancy mode | |||
Media redundancy | |||
— MRP | Yes | Yes | Yes |
Open IE communication | |||
● TCP/IP | No | No | No |
● SNMP | Yes | Yes | Yes |
● DCP | Yes | Yes | Yes |
● LLDP | Yes | Yes | Yes |
● ping | Yes | Yes | Yes |
● ARP | Yes | Yes | Yes |
Interrupts/diagnostics/status information | |||
Diagnostics function | Yes | Yes | Yes |
Alarms | |||
● Diagnostic alarm | Yes | Yes | Yes |
Diagnoses | |||
● Diagnostic information readable | Yes | Yes | Yes |
● Monitoring the supply voltage | Yes; green “ON” LED | Yes; green “ON” LED | Yes; green “ON” LED |
● Wire-break in signal transmitter cable | Yes | Yes | Yes |
● Short-circuit encoder supply | Yes; Per channel group | Yes; Per channel group | Yes; Per channel group |
● Group error | Yes; Red/yellow “SF/MT” LED | Yes; Red/yellow “SF/MT” LED | Yes; Red/yellow “SF/MT” LED |
Potential separation | |||
between the load voltages | Yes | Yes | Yes |
between load voltage and all other switching components | No | No | No |
between Ethernet and electronics | Yes | Yes | Yes |
Potential separation channels | |||
● between the channels | No | No | No |
Isolation | |||
tested with | |||
● 24 V DC circuits | 707 V DC (type test) | 707 V DC (type test) | 707 V DC (type test) |
● Test voltage for interface, rms value [Vrms] | 1 500 V; According to IEEE 802.3 | 1 500 V; According to IEEE 802.3 | 1 500 V; According to IEEE 802.3 |
Degree and class of protection | |||
IP degree of protection | IP65/67 | IP65/67 | IP65/67 |
connection method / header | |||
Design of electrical connection | 4/5-pin M12 circular connectors | 4/5-pin M12 circular connectors | 4/5-pin M12 circular connectors |
Dimensions | |||
Width | 30 mm | 60 mm | 60 mm |
Height | 200 mm | 175 mm | 175 mm |
Depth | 49 mm | 49 mm | 49 mm |
Weights | |||
Weight, approx. | 550 g | 910 g | 910 g |
Article number | 6ES7142-6BF50-0AB0 | 6ES7142-6BF00-0AB0 | 6ES7142-6BG00-0AB0 | 6ES7142-6BR00-0AB0 | 6ES7142-6BH00-0AB0 |
ET200eco PN, 8DO, DC24V/0,5A, 4xM12 | ET200eco PN, 8DO, DC24V/1,3A, 4xM12 | ET200eco PN, 8DO, DC24V/1,3A, 8xM12 | ET200eco PN, 8 DO, DC24V/2A, 8xM12 | ET200eco PN, 16DO DC24V/1,3A, 8xM12 | |
General information | |||||
Vendor identification (VendorID) | 002AH | 002AH | 002AH | 002AH | 002AH |
Device identifier (DeviceID) | 0306H | 0306H | 0306H | 0306H | 0306H |
Supply voltage | |||||
Rated value (DC) | 24 V | 24 V | 24 V | 24 V | 24 V |
Reverse polarity protection | Yes | Yes | Yes | Yes | Yes |
power supply according to NEC Class 2 required | Yes | Yes | Yes | Yes | Yes |
Load voltage 1L+ | |||||
● Rated value (DC) | 24 V | 24 V | 24 V | 24 V | 24 V |
● permissible range, lower limit (DC) | 20.4 V | 20.4 V | 20.4 V | 20.4 V | 20.4 V |
● permissible range, upper limit (DC) | 28.8 V | 28.8 V | 28.8 V | 28.8 V | 28.8 V |
● Reverse polarity protection | Yes | Yes | Yes | Yes | Yes |
Load voltage 2L+ | |||||
● Rated value (DC) | 24 V | 24 V | 24 V | 24 V | 24 V |
● permissible range, lower limit (DC) | 20.4 V | 20.4 V | 20.4 V | 20.4 V | 20.4 V |
● permissible range, upper limit (DC) | 28.8 V | 28.8 V | 28.8 V | 28.8 V | 28.8 V |
● Reverse polarity protection | Yes | Yes | Yes | Yes | Yes |
Input current | |||||
Current consumption, typ. | 100 mA | 100 mA | 100 mA | 100 mA | 100 mA |
from supply voltage 1L+, max. | 4 A | 4 A | 4 A | 4 A | 4 A |
from load voltage 1L+ (unswitched voltage) | 100 mA | 4 A | 4 A | 4 A | 4 A |
from load voltage 2L+, max. | 4 A | 4 A | 4 A | 4 A | 4 A |
Power loss | |||||
Power loss, typ. | 3 W | 5.5 W | 5.5 W | 5 W | 5.5 W |
Digital outputs | |||||
Number of digital outputs | 8 | 8 | 8 | 8 | 16 |
● in groups of | 8 | 4 | 4 | 4 | 8 |
Short-circuit protection | Yes | Yes | Yes | Yes | Yes |
● Response threshold, typ. | 0.7 A | 1.8 A | 1.8 A | 2.8 A | 1.8 A |
Limitation of inductive shutdown voltage to | Typ. (L1+, L2+) -47 V | Typ. (L1+, L2+) -47 V | Typ. (L1+, L2+) -47 V | Typ. (L1+, L2+) -47 V | Typ. (L1+, L2+) -47 V |
Controlling a digital input | Yes | Yes | Yes | Yes | Yes |
Switching capacity of the outputs | |||||
● on lamp load, max. | 5 W | 5 W | 5 W | 10 W | 5 W |
Output current | |||||
● for signal “1” rated value | 0.5 A | 1.3 A; Maximum | 1.3 A; Maximum | 2 A | 1.3 A; Maximum |
● for signal “0” residual current, max. | 1.5 mA | 1.5 mA | 1.5 mA | 1.5 mA | 1.5 mA |
Parallel switching of two outputs | |||||
● for uprating | No | No | No | No | No |
● for redundant control of a load | Yes | Yes | Yes | Yes | Yes |
Switching frequency | |||||
● with resistive load, max. | 100 Hz | 100 Hz | 100 Hz | 100 Hz | 100 Hz |
● with inductive load, max. | 0.5 Hz | 0.5 Hz | 0.5 Hz | 0.5 Hz | 0.5 Hz |
● on lamp load, max. | 1 Hz | 1 Hz | 1 Hz | 1 Hz | 1 Hz |
Total current of the outputs (per group) | |||||
all mounting positions | |||||
— up to 55 °C, max. | 3.9 A | ||||
— up to 60 °C, max. | 4 A | 2.6 A | 3.9 A | 3.9 A | 3.9 A |
Cable length | |||||
● unshielded, max. | 30 m | 30 m | 30 m | 30 m | 30 m |
Interfaces | |||||
Transmission procedure | 100BASE-TX | 100BASE-TX | 100BASE-TX | 100BASE-TX | 100BASE-TX |
Number of PROFINET interfaces | 1 | 1 | 1 | 1 | 1 |
1. Interface | |||||
Interface types | |||||
● M12 port | Yes | ||||
● integrated switch | Yes | Yes | Yes | Yes | Yes |
Interface types | |||||
M12 port | |||||
● Autonegotiation | Yes | Yes | Yes | Yes | Yes |
● Autocrossing | Yes | Yes | Yes | Yes | Yes |
● Transmission rate, max. | 100 Mbit/s | 100 Mbit/s | 100 Mbit/s | 100 Mbit/s | 100 Mbit/s |
Protocols | |||||
Supports protocol for PROFINET IO | Yes | Yes | Yes | Yes | Yes |
PROFINET CBA | No | No | No | No | No |
PROFIsafe | No | No | No | No | No |
PROFINET IO Device | |||||
Services | |||||
— IRT with the option “high flexibility” | Yes | Yes | Yes | Yes | Yes |
— Prioritized startup | Yes | Yes | Yes | Yes | Yes |
Redundancy mode | |||||
Media redundancy | |||||
— MRP | Yes | Yes | Yes | Yes | Yes |
Open IE communication | |||||
● TCP/IP | No | No | No | No | No |
● SNMP | Yes | Yes | Yes | Yes | Yes |
● DCP | Yes | Yes | Yes | Yes | Yes |
● LLDP | Yes | Yes | Yes | Yes | Yes |
● ping | Yes | Yes | Yes | Yes | Yes |
● ARP | Yes | Yes | Yes | Yes | Yes |
Interrupts/diagnostics/status information | |||||
Diagnostics function | Yes | Yes | Yes | Yes | Yes |
Alarms | |||||
● Diagnostic alarm | Yes | Yes | Yes | Yes | Yes |
Diagnoses | |||||
● Diagnostic information readable | Yes | Yes | Yes | Yes | Yes |
● Monitoring the supply voltage | Yes; green “ON” LED | Yes; green “ON” LED | Yes; green “ON” LED | Yes; green “ON” LED | Yes; green “ON” LED |
● Wire-break in actuator cable | Yes | Yes | Yes | Yes | Yes |
● Short-circuit | Yes | Yes | Yes | Yes | Yes |
● Group error | Yes; Red/yellow “SF/MT” LED | Yes; Red/yellow “SF/MT” LED | Yes; Red/yellow “SF/MT” LED | Yes; Red/yellow “SF/MT” LED | Yes; Red/yellow “SF/MT” LED |
Potential separation | |||||
between the load voltages | Yes | Yes | Yes | Yes | Yes |
between load voltage and all other switching components | No | No | No | No | No |
between Ethernet and electronics | Yes | Yes | Yes | Yes | Yes |
Potential separation channels | |||||
● between the channels | No | No | No | No | No |
Isolation | |||||
tested with | |||||
● 24 V DC circuits | 707 V DC (type test) | 707 V DC (type test) | 707 V DC (type test) | 707 V DC (type test) | 707 V DC (type test) |
● Test voltage for interface, rms value [Vrms] | 1 500 V; According to IEEE 802.3 | 1 500 V; According to IEEE 802.3 | 1 500 V; According to IEEE 802.3 | 1 500 V; According to IEEE 802.3 | 1 500 V; According to IEEE 802.3 |
Degree and class of protection | |||||
IP degree of protection | IP65/67 | IP65/67 | IP65/67 | IP65/67 | IP65/67 |
Standards, approvals, certificates | |||||
Suitable for safety-related tripping of standard modules | Yes | Yes | Yes | Yes | Yes |
Highest safety class achievable for safety-related tripping of standard modules | |||||
● Performance level according to ISO 13849-1 | PL d | PL d | PL d | PL d | PL d |
● Category according to ISO 13849-1 | Cat. 3 | Cat. 3 | Cat. 3 | Cat. 3 | Cat. 3 |
● SIL acc. to IEC 62061 | SIL 2 | SIL 2 | SIL 2 | SIL 2 | SIL 2 |
connection method / header | |||||
Design of electrical connection | 4/5-pin M12 circular connectors | 4/5-pin M12 circular connectors | 4/5-pin M12 circular connectors | 4/5-pin M12 circular connectors | 4/5-pin M12 circular connectors |
Dimensions | |||||
Width | 30 mm | 30 mm | 60 mm | 60 mm | 60 mm |
Height | 200 mm | 200 mm | 175 mm | 175 mm | 175 mm |
Depth | 49 mm | 49 mm | 49 mm | 49 mm | 49 mm |
Weights | |||||
Weight, approx. | 550 g | 550 g | 910 g | 910 g | 910 g |
Article number | 6ES7147-6BG00-0AB0 |
ET200eco PN, 8 DIO, DC24V/1,3A, 8xM12 | |
General information | |
Vendor identification (VendorID) | 002AH |
Device identifier (DeviceID) | 0306H |
Supply voltage | |
Rated value (DC) | 24 V |
Reverse polarity protection | Yes |
power supply according to NEC Class 2 required | Yes |
Load voltage 2L+ | |
● Rated value (DC) | 24 V |
● permissible range, lower limit (DC) | 20.4 V |
● permissible range, upper limit (DC) | 28.8 V |
● Reverse polarity protection | Yes |
Input current | |
Current consumption, typ. | 100 mA |
from supply voltage 1L+, max. | 4 A |
from load voltage 1L+ (unswitched voltage) | 4 A |
from load voltage 2L+, max. | 4 A |
Encoder supply | |
24 V encoder supply | |
● Short-circuit protection | Yes; Electronic |
● Output current, max. | 100 mA; per output |
Power loss | |
Power loss, typ. | 6.5 W |
Digital inputs | |
Number of digital inputs | 8 |
● in groups of | 4 |
Input characteristic curve in accordance with IEC 61131, type 3 | Yes |
Number of simultaneously controllable inputs | |
all mounting positions | |
— up to 60 °C, max. | 8 |
Input voltage | |
● Rated value (DC) | 24 V |
● for signal “0” | -3 to +5V |
● for signal “1” | +11 to +30V |
Input current | |
● for signal “1”, typ. | 7 mA |
Input delay (for rated value of input voltage) | |
for standard inputs | |
— at “0” to “1”, max. | typically 3 ms |
— at “1” to “0”, max. | typically 3 ms |
Cable length | |
● unshielded, max. | 30 m |
Digital outputs | |
Number of digital outputs | 8 |
● in groups of | 4 |
Short-circuit protection | Yes; Electronic |
● Response threshold, typ. | 1.8 A |
Limitation of inductive shutdown voltage to | Typ. (L1+, L2+) -47 V |
Controlling a digital input | Yes |
Switching capacity of the outputs | |
● on lamp load, max. | 5 W |
Output current | |
● for signal “1” rated value | 1.3 A; Maximum |
● for signal “1” permissible range, max. | 1.3 A |
● for signal “0” residual current, max. | 1.5 mA |
Parallel switching of two outputs | |
● for uprating | No |
● for redundant control of a load | Yes |
Switching frequency | |
● with resistive load, max. | 100 Hz |
● with inductive load, max. | 0.5 Hz |
● on lamp load, max. | 1 Hz |
Total current of the outputs (per group) | |
all mounting positions | |
— up to 60 °C, max. | 3.9 A |
Cable length | |
● unshielded, max. | 30 m |
Encoder | |
Connectable encoders | |
● 2-wire sensor | Yes |
— permissible quiescent current (2-wire sensor), max. | 1.5 mA |
Interfaces | |
Transmission procedure | 100BASE-TX |
Number of PROFINET interfaces | 1 |
1. Interface | |
Interface types | |
● M12 port | Yes |
● integrated switch | Yes |
Interface types | |
M12 port | |
● Autonegotiation | Yes |
● Autocrossing | Yes |
● Transmission rate, max. | 100 Mbit/s |
Protocols | |
Supports protocol for PROFINET IO | Yes |
PROFINET CBA | No |
PROFIsafe | No |
PROFINET IO Device | |
Services | |
— IRT with the option “high flexibility” | Yes |
— Prioritized startup | Yes |
Redundancy mode | |
Media redundancy | |
— MRP | Yes |
Open IE communication | |
● TCP/IP | No |
● SNMP | Yes |
● DCP | Yes |
● LLDP | Yes |
● ping | Yes |
● ARP | Yes |
Interrupts/diagnostics/status information | |
Diagnostics function | Yes |
Alarms | |
● Diagnostic alarm | Yes |
Diagnoses | |
● Diagnostic information readable | Yes |
● Monitoring the supply voltage | Yes; green “ON” LED |
● Wire-break in actuator cable | Yes |
● Wire-break in signal transmitter cable | Yes |
● Short-circuit | Yes |
● Short-circuit encoder supply | Yes |
● Group error | Yes; Red/yellow “SF/MT” LED |
Potential separation | |
between the load voltages | Yes |
between load voltage and all other switching components | No |
between Ethernet and electronics | Yes |
Potential separation channels | |
● between the channels | No |
Isolation | |
tested with | |
● 24 V DC circuits | 707 V DC (type test) |
● Test voltage for interface, rms value [Vrms] | 1 500 V; According to IEEE 802.3 |
Degree and class of protection | |
IP degree of protection | IP65/67 |
Standards, approvals, certificates | |
Suitable for safety-related tripping of standard modules | No |
connection method / header | |
Design of electrical connection | 4/5-pin M12 circular connectors |
Dimensions | |
Width | 60 mm |
Height | 175 mm |
Depth | 49 mm |
Weights | |
Weight, approx. | 910 g |
Weight | N/A |
---|---|
Dimensions | N/A |
Related products
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details