Safety outputsAuxiliary outputs
*3
Max. OFF-delay
time *1
Rated voltageModel
InstantaneousOFF-delayed *2
DPST-NO1 (Solid-state)24 VDCG9SE-201
4PST-NOG9SE-401
DPST-NODPST-NO5 sG9SE-221-T05
DPST-NODPST-NO30 sG9SE-221-T30

Specification

Power Input

ModelG9SE-201G9SE-401G9SE-221-T[]
Rated supply voltage24 VDC
Operating voltage range-15% to 10% of rated supply voltage
Rated power consumption *13 W max.4 W max.

Outputs

ModelG9SE-201G9SE-401G9SE-221-T[]
Safety output
OFF-delayed Safety output
Contact output
250 VAC 5 A 30 VDC 5 A (resistive load)
Auxiliary outputPNP transistor output Load current: 100 mA DC max.

 

Characteristics

ModelG9SE-201G9SE-401G9SE-221-T[]
Operating time (OFF to ON state) *2100 ms Max. *3
Response time (ON to OFF state) *415 ms Max.
Accuracy of OFF-delay timeWithin plus or minus
10% of the set value
InputsInput current5 mA Min.
ON voltage11 VDC Min.
OFF voltage5 VDC Max.
OFF current1 mA Max.
Maximum cable length100 m Max.
Reset input time250 ms Min.
Contact
outputs
Contact resistance *5100 mΩ
Mechanical durability5,000,000 operations Min.
Electrical durability50,000 operations Min.
Switching specification Inductive
load (IEC/EN60947-5-1)
AC15: 240 VAC 2 A
DC13: 24 VDC 1.5 A
Minimum applicable load24 VDC 4 mA
Conditional short-circuit current
(IEC/EN60947-5-1)
100 A *6
Pollution degree2
Over voltage category (IEC/EN60664-1)Safety output: Class III, the others: Class II
Insulation
specification
Isolation voltage (Ui)250 VAC
Impulse
withstand
voltage
(IEC/
EN60947-5-1)
Between input and
output
6 kV
Between different
poles of output
6 kV (between 13-14/23-24 and 33-34/43-44 (37-38/47-48))
4 kV (between 13-14 and 23-24, between 33-34 (37-38) and
43-44 (47-48))
Dielectric
strength
Between input and
output
2,200 VDC
Between different
poles of output
1,500 VAC
Insulation resistance100 MΩ
Vibration resistance *7Frequency: 10 to 55 to 10 Hz
Amplitude: 0.35 mm half amplitude (0.7 mm double amplitude)
Mechanical
shock re-
sistance *7
Destruction300 m/s2
Malfunction100 m/s2
Surrounding Air Temperature-10 to 55°C (No freezing or condensation)
Ambient humidity25% to 85%RH
Degree of protectionIP20
Weightapprox. 150 gapprox. 180 g
*1 Power consumption of loads not included.
*2 The operating time is the time it takes for the safety contact to close after the safety inputs and feedback-reset input are turned ON. Not includes bounce time.
*3 This is in normal operation. When executing non-regular self-diagnosis for Safety output circuit, G9SE operating time become 500 ms max..
*4 The response time is the time it takes for the safety main contact to open after the safety input is turned OFF. Includes bouncetime.
*5 This is initial value using the voltage-drop method with 1A at 5VDC.
*6 Use for each contact output an 8A fuse that conforms to IEC 60127 as a short-circuit protection device. This fuse is not included with the G9SE.
*7 Condition: G9SE is mounted to mounting surface with screw and the screw mounting attachment. In the case of DIN rail mounting, mount DIN rail with G9SE to the place without big vibration. (Amplitude guideline: Less than 0.15 mm half amplitude (0.3 mm double amplitude))