$ 11.50 – $ 29.44
Phoenix Contact develops terminal blocks, distribution blocks, power supplies, relays, connectors, signal conditioners, controllers & PLCs, I/O systems, Industrial Ethernet, controller system cabling, PCB terminal blocks & connectors, and surge suppression.
Distribution block, the blocks can be bridged with one another via the conductor shaft, for corresponding plug-in bridges, see accessories, Block with horizontal alignment and integrated supply, nom. voltage: 690 V, nominal current: 24 A, connection method: Push-in connection, Load contact, cross section: 0.14 mm² – 4 mm², Push-in connection, Line contact, Rated cross section: 6 mm², cross section: 0.5 mm² – 10 mm², mounting type: NS 35/7,5, NS 35/15, color: gray
Note | Notes on operation the blocks can be bridged with one another via the conductor shaft, for corresponding plug-in bridges, see accessories |
---|---|
Part Number | 3273198 |
Number of rows | 1 |
Number of connections | 7 |
Potentials | 1 |
Nominal cross section | 2.5 mm² |
Color | gray |
Insulating material | PA |
Flammability rating according to UL 94 | V0 |
Mounting type | NS 35/7,5 |
Rated surge voltage | 8 kV |
Degree of pollution | 3 |
Overvoltage category | III |
Insulating material group | I |
Maximum power dissipation for nominal condition | 0.77 W |
Maximum load current | 32 A (with 4 mm² conductor cross section) |
Maximum total current | 57 A (with 10 mm² conductor cross section) |
Nominal current IN | 24 A |
Nominal voltage UN | 690 V |
Maximum load current | 57 A (with 10 mm² conductor cross section) |
Nominal current IN | 41 A (with 6 mm² conductor cross section) |
Open side panel | No |
General information | The maximum load current of a single clamping unit must not be exceeded. For power distribution applications, IEC 60364-4-43.2008; modified + corrigendum Okt. 2008 (DIN VDE 0100-430:2010-10) section 433.2 ff must be observed! |
Shock protection test specification | DIN EN 50274 (VDE 0660-514):2002-11 |
Back of the hand protection | guaranteed |
Finger protection | guaranteed |
Result of surge voltage test | Test passed |
Result of power-frequency withstand voltage test | Test passed |
Power frequency withstand voltage setpoint | 1.89 kV |
Result of the test for mechanical stability of terminal points (5 x conductor connection) | Test passed |
Result of flexion and pull-out test | Test passed |
Bending test rotation speed | 10 rpm |
Bending test turns | 135 |
Bending test conductor cross section/weight | 0.5 mm² / 0.3 kg |
6 mm² / 1.4 kg | |
10 mm² / 2 kg | |
0.14 mm² / 0.2 kg | |
2.5 mm² / 0.7 kg | |
4 mm² / 0.9 kg | |
Tensile test result | Test passed |
Conductor cross section tensile test | 0.5 mm² |
Tractive force setpoint | 20 N |
Conductor cross section tensile test | 6 mm² |
Tractive force setpoint | 80 N |
Conductor cross section tensile test | 10 mm² |
Tractive force setpoint | 90 N |
Conductor cross section tensile test | 0.14 mm² |
Tractive force setpoint | 10 N |
Result of tight fit on support | Test passed |
Tight fit on carrier | NS 35 |
Setpoint | 5 N |
Note | When aligning several blocks, it is recommended to either place a DIN rail adapter underneath the connection point or a flange element between the blocks. |
For versions with 6 or 7 connections, it is enough to place one DIN rail adapter centrally per block and place flange elements after every other block. | |
When using the DIN rail adapter PTFIX-NS35, an aligned block must not protrude by more than a half. | |
Result of voltage-drop test | Test passed |
Requirements, voltage drop | U1 ≤ 3.2 mV; U2 ≤ 1.5 x U1 |
Result of temperature-rise test | Test passed |
Requirement temperature-rise test | Increase in temperature ≤ 45 K |
Short circuit stability result | Test passed |
Conductor cross section short circuit testing | 6 mm² |
Short-time current | 0.72 kA |
Conductor cross section short circuit testing | 10 mm² |
Short-time current | 1.2 kA |
Result of thermal test | Test passed |
Proof of thermal characteristics (needle flame) effective duration | 30 s |
Result of aging test | Test passed |
Ageing test for screwless modular terminal block temperature cycles | 192 |
Oscillation, broadband noise test result | Test passed |
Test specification, oscillation, broadband noise | DIN EN 50155 (VDE 0115-200):2008-03 |
Test spectrum | Service life test category 2, bogie-mounted |
Test frequency | f1 = 5 Hz to f2 = 250 Hz |
ASD level | 6.12 (m/s²)²/Hz |
Acceleration | 3.12g |
Test duration per axis | 5 h |
Test directions | X-, Y- and Z-axis |
Shock test result | Test passed |
Test specification, shock test | DIN EN 50155 (VDE 0115-200):2008-03 |
Shock form | Half-sine |
Acceleration | 30g |
Shock duration | 18 ms |
Number of shocks per direction | 3 |
Test directions | X-, Y- and Z-axis (pos. and neg.) |
Relative insulation material temperature index (Elec., UL 746 B) | 130 °C |
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) | 130 °C |
Static insulating material application in cold | -60 °C |
Surface flammability NFPA 130 (ASTM E 162) | passed |
Specific optical density of smoke NFPA 130 (ASTM E 662) | passed |
Calorimetric heat release NFPA 130 (ASTM E 1354) | 28 MJ/kg |
Smoke gas toxicity NFPA 130 (SMP 800C) | passed |
Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 – HL 3 |
Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 – HL 3 |
Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 – HL 3 |
Fire protection for rail vehicles (DIN EN 45545-2) R26 | HL 1 – HL 3 |
Width | 25.6 mm |
---|---|
Length | 45.7 mm |
Height NS 35/7,5 | 30.9 mm |
Connection | Load contact |
---|---|
Connection method | Push-in connection |
Stripping length | 8 mm … 10 mm |
Connection in acc. with standard | IEC 60947-7-1 |
Conductor cross section solid min. | 0.14 mm² |
Conductor cross section solid max. | 4 mm² |
Conductor cross section AWG min. | 26 |
Conductor cross section AWG max. | 12 |
Conductor cross section flexible min. | 0.14 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Min. AWG conductor cross section, flexible | 26 |
Max. AWG conductor cross section, flexible | 14 |
Conductor cross section flexible, with ferrule without plastic sleeve min. | 0.14 mm² |
Conductor cross section flexible, with ferrule without plastic sleeve max. | 2.5 mm² |
Conductor cross section flexible, with ferrule with plastic sleeve min. | 0.14 mm² |
Conductor cross section flexible, with ferrule with plastic sleeve max. | 2.5 mm² |
Connection cross sections directly pluggable | 0.34 mm² 4 mm² 24 12 |
Conductor cross section solid min. | 0.34 mm² |
Conductor cross section solid max. | 4 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 12 |
Conductor cross section flexible, with ferrule without plastic sleeve min. | 0.34 mm² |
Conductor cross section flexible, with ferrule without plastic sleeve max. | 2.5 mm² |
Conductor cross section flexible, with ferrule with plastic sleeve min. | 0.34 mm² |
Conductor cross section flexible, with ferrule with plastic sleeve max. | 2.5 mm² |
Internal cylindrical gage | A3 |
Connection | Line contact |
Connection method | Push-in connection |
Stripping length | 10 mm … 12 mm |
Connection in acc. with standard | IEC 60947-7-1 |
Conductor cross section solid min. | 0.5 mm² |
Conductor cross section solid max. | 10 mm² |
Conductor cross section AWG min. | 20 |
Conductor cross section AWG max. | 8 |
Conductor cross section flexible min. | 0.5 mm² |
Conductor cross section flexible max. | 10 mm² |
Min. AWG conductor cross section, flexible | 20 |
Max. AWG conductor cross section, flexible | 10 |
Conductor cross section flexible, with ferrule without plastic sleeve min. | 0.5 mm² |
Conductor cross section flexible, with ferrule without plastic sleeve max. | 6 mm² |
Conductor cross section flexible, with ferrule with plastic sleeve min. | 0.5 mm² |
Conductor cross section flexible, with ferrule with plastic sleeve max. | 6 mm² |
Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum | 0.5 mm² |
Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum | 1.5 mm² |
Connection cross sections directly pluggable | 1 mm² 10 mm² |
Conductor cross section solid min. | 1 mm² |
Conductor cross section solid max. | 10 mm² |
Value | 1 mm² |
6 mm² | |
1 mm² | |
6 mm² |
Operating temperature | -60 °C … 105 °C (max. short-term operating temperature RTI Elec.) |
---|---|
Ambient temperature (storage/transport) | -25 °C … 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C) |
Permissible humidity (storage/transport) | 30 % … 70 % |
Ambient temperature (assembly) | -5 °C … 70 °C |
Ambient temperature (actuation) | -5 °C … 70 °C |
Connection in acc. with standard | IEC 60947-7-1 |
---|---|
IEC 60947-7-1 |
China RoHS | Environmentally friendly use period: unlimited = EFUP-e |
---|---|
No hazardous substances above threshold values |
INOSAKI Limited
RM B 5/F Gaylord Comm,
Bldg 114-118 Lockhart Rd.
Hong Kong
INOSAKI Sdn. Bhd.
2-1-9, Ground Floor, One Square, Tingkat Mahsuri 1,
11900 Bayan Lepas, Penan
INOSAKI Pte. Ltd.
101 Upper Cross Street,
No. 06-17, People’s Park Centre,
Singapore (058357)