MK500 Series – AMK5005P54 -Frequency converter MK500 – Panasonic Compact inverters

USD $ 381.36

SKU: AMK5005P54

Specification

project content
Order product number AMK5005P54
Model AMK5005P54
Standard motor output (kW) 0.75kW ~ 15kW
Rated output : Rated voltage Three-phase 380V (supply voltage ratio, error less than 5%)
Rated output : Overload current rating 150% of rated output current 89s, 180% of rated output current 10s, 200% 3s of rated output current
Input power supply: phase number, voltage, frequency Three-phase 380V 50Hz/60Hz
Input power : Voltage is allowed to vary +3% of rated input AC voltage
Input power : Frequency allowed to vary ±5% of rated input frequency
Input power : Instantaneous voltage reduction tolerance Continue operation above 320V AC Reduced to less than 320V AC when an undervoltage fault is reported
Output Frequency : Frequency range 0Hz~500Hz
Output Frequency : Frequency display Digital display
Output Frequency : Frequency accuracy Analog setting: within 0.02% of the maximum set frequency ± When setting digitally: within 0.01 of the maximum set frequency ±
Output Frequency : Frequency resolution Digital setting: 0.01Hz Analog setting: Maximum frequency ×0.05%
Inverter control mode V/F control, open-loop vector control, closed-loop vector control
Carrier frequency 1.0kHz~16.0kHz
Run : Run • Stop Operation panel switch, multi-function terminal control (can be set to prohibit reversal), RS-485 communication
Run : Forward or reverse Operation panel switch, multi-function terminal control (can be set to prohibit reversal), RS-495 communication
Run : Jog run The operating frequency is arbitrarily set from 0.00Hz~500.00Hz, and the acceleration and deceleration time is 0.01 seconds ~ 650 seconds
Run : Stop mode Deceleration stop • Inertial stop (choose to switch)
Run : Reset function Stop signal reset • External reset • Power supply reset
Run : Start frequency At 0.00Hz~500.00Hz (limited by upper frequency)
Run : Stop frequency At 0.00Hz~500.00Hz (limited by upper frequency)
Run : Stop and start running again Start by start frequency, track start by speed (select switch)
Run : Speed Search Speed search at startup (configurable)
Run : Retry the function Retry selection: function with/without Number of re-attempts: 1 time ~ 10 times arbitrary setting Retry interval: 1.0 seconds ~ 100.0 seconds set arbitrarily
Control : Frequency setting signal Panel settings: keypad number settings Built-in keyboard potentiometer Analog setting signal for external operation: External single-line keyboard potentiometer Voltage/current analog AI1 is given Voltage/current analog AI2 is given External control operation digital setting signal: Terminal pulse PUL Terminal UP/DW control Terminal PWM control Communication settings: RS-485 communication Shop for cards Internal settings: PID settings Program Control (PLC) Multi-segment speed is given
Control : Voltage/frequency characteristics The default is 50.00Hz, and it can be set arbitrarily at 0Hz ~ 500Hz Four ways: linear torque characteristic curve, self-setting V/F curve, falling torque characteristic curve (1.1 power ~ 2.1 power), square V/F curve. V/F Energy Saving Mode (Selectable)
Control : Torque boost Automatic torque increased by 0.0% ~ 100.0%; Manual torque increase 0.0% ~ 30.0%
Control : Acceleration and deceleration time 0.01 sec. ~ 650 sec. (individual settings for acceleration and deceleration)
Control : Acceleration and deceleration characteristics Straight line, S-shaped acceleration and deceleration (optional)
Control : Multi-speed frequency setting Up to 15 speed can be set (any set frequency) The running time of each speed and the acceleration and deceleration times can be set separately
Control : Frequency jump setting Up to two jump frequencies can be set (The jump frequency amplitude is 2Hz ~ the maximum frequency can be set arbitrarily)
Control : Upper limit frequency setting 0.00Hz ~ maximum frequency can be set arbitrarily
Control : Lower limit frequency setting 0.00Hz ~ upper limit frequency set arbitrarily
Control: Bias • gain frequency setting No bias frequency Gain frequency: 0% ~ 500% arbitrary setting
Control : External stop function External fault stop, emergency stop (multi-function terminal selection)
Control : PID function PID control mode (configurable)
Control : Offline autotune function Automatic tuning of motor constants
Control : Cooling fan ON/OFF control Configurable
Control : Communication functions Interface: RS-485 serial communication · Communication speed: 1200/2400/4800/9600/19200/38400/57600 bps (optional) · Protocol: MEWTOCOL-COM/Modbus (RTU)/Modbus-ASCII (opt-in switch) · Communication mode: half-duplex mode · Maximum number of connections: 32 · Maximum transmission distance: 50m
Braking : DC braking Starting frequency: 0.00Hz ~ 50.00Hz set arbitrarily Braking time: 0.0s ~ 60.0s arbitrary setting; Braking current: 0.0% ~ 150.0% The rated current can be set arbitrarily
Output signal : Analog output One AO output can be selected as 1V ~ 0V or 10mA ~ 0mA or 20mA ~ 4mA output Output function: output frequency, given frequency, output current, input voltage, output voltage, motor speed, PID feedback amount, PID given amount, module temperature, given torque, output torque, etc. (optional)
Output signal: Open collector output Output specifications: maximum rated 24V DC, 50mA Output function: running signal, given frequency arrival, overload alarm, frequency detection, reversal signal, abnormal alarm, frequency detection, etc. (optional)
Output signal : Relay output Output specification: passive contact output (3A/240V AC 5A/29V DC) Output functions: running signal, frequency arrival signal, overload alarm, frequency detection, reversal signal, abnormal alarm, current detection, timer end signal, etc. (optional)
Display : Running•Control Status Output frequency, given frequency, output current, input voltage, output voltage, motor speed, PID feedback amount, PID All parameters of a group of monitoring parameters such as a given amount, module temperature, given torque, output torque, terminal on status, etc
Display : Abnormal content Overvoltage, undervoltage, overcurrent, short circuit, phase loss, overload, overtemperature, overvoltage stall, current limiting, data protection breached, current fault operating status, historical fault
Protection : Current limit The current limit function can be set at 0.1% ~ 300.0% of the rated output current
Protection : Trip (stop) Instantaneous overcurrent (SC), temperature anomaly (OH), overcurrent (OC), inverter overload and motor overload (OL), insufficient voltage (LU), overvoltage (OU), cooling fan fault (FSG), external abnormality (EF), input and output phase loss (LF), CPU fault (CPU), etc
Protection : Stall prevention function Prevent overcurrent stall and prevent overvoltage stall
Environment : Use ambient temperature and humidity -10°C~ +50°C, derating can be used above 40 °C, maximum temperature 60°C (no-load operation) 5%RH ~ 95%RH (non-condensing)
Environment : Storage temperature and humidity -30°C ~ +60°C (no freezing, no condensation), storage humidity 95%RH or lower (no condensation)
Environment : Vibration 9.200m/s² (5.9G) at 0Hz ~ 6Hz
Environment : Elevation The elevation is below 1000m
Environment : Place of use If the altitude is less than 1000 meters, the derating is used for more than 1000 meters, and the derating is reduced by 100% for each 1 meters of increase; No condensation, ice, rain, snow, hail, etc., solar radiation less than 700W/m², air pressure 70kPa ~ 106kPa
Protection Construct IP20
Cooling method MK500 0.4kW, 0.75kW: self-cooling, others: air-cooled