Limit Switches OsiSense XC Standard – XCMN – Schneider Limit Switches

USD $ 20.37USD $ 39.48

SKU: N/A

Specifications

Main information
Part Number XCMN2102L1 XCMN2102L2 XCMN2103L1 XCMN2106L1
Product Series Telemecanique Limit switches XC Standard Telemecanique Limit switches XC Standard Telemecanique Limit switches XC Standard Telemecanique Limit switches XC Standard
Serial Number Standard type Standard format Standard type Standard type
product type Limit switch Limit switch Limit switch Limit switch
product short name XCMN XCMN XCMN XCMN
sensor design Miniature Miniature Miniature Miniature
ontology type Fixed Fixed Fixed Fixed
Control head type Direct acting head Plunger head Direct acting head Universal head
Material Plastic Plastic Plastic Plastic
body material Plastic Plastic Plastic Plastic
head material Zamak Zamak Zamak Zamak
fixed mode By ontology By the body By ontology By ontology
Operation head movement Linear Linear Linear Universal
Operating head type Spring Return, Roller Direct Action Metal Spring return roller plunger metal Spring Return, Roller Direct Action Metal Spring return whisker
method type Lateral movement, 2-way Lateral approach, 2 directions Lateral movement, 2-way Universal motion
number of poles 2 2 2 2
contact type 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO
contact action Momentary Snap action Momentary Momentary
Additional information
switch trigger 30° lip By 30° cam 30° lip Any moving parts
Electrical connections Fixed cable Fixed cable Fixed cable Fixed cable
cable length 1 m 2 m 1 m 1 m
Cable composition 4 x 0.75 mm² 4 x 0.75 mm² 4 x 0.75 mm² 4 x 0.75 mm²
wire insulation PvR PvR PvR PvR
Type of contact wire insulation Zb Zb Zb Zb
force open Have With Have None
force open minimum force 35N 35 N 35N
Minimum trip force 7 N 7 N 7 N 0.1N
operating speed 0.5 m/s 0.5 m/s 0.5 m/s 1 m/s
Contact wire regulation grade B300, AC-15 (Ue = 240 V), Ie = 1.5 A conforming to EN/IEC 60947-5-1 Appendix A B300, AC-15 (Ue = 240 V), Ie = 1.5 A conforming to EN/IEC 60947-5-1 appendix A B300, AC-15 (Ue = 240 V), Ie = 1.5 A conforming to EN/IEC 60947-5-1 Appendix A R300, DC- B300, AC-15 (Ue = 240 V), Ie = 1.5 A conforming to EN/IEC 60947-5-1 Appendix A R300, DC-
R300, DC-13 (Ue = 250 V), Ie = 0.1 A conforming to EN/IEC 60947-5 -1 Appendix A R300, DC-13 (Ue = 250 V), Ie = 0.1 A conforming to EN/IEC 60947-5-1 appendix A 13 (Ue = 250 V), Ie = 0.1 A conforming to EN/IEC 60947-5 -1 Appendix A 13 (Ue = 250 V), Ie = 0.1 A conforming to EN/IEC 60947-5 -1 Appendix A
Rated insulation voltage [Ui] 300 V (pollution degree 3) according to UL 508 300 V (pollution degree 3) conforming to UL 508 300 V (pollution degree 3) according to UL 508 300 V (pollution degree 3) according to UL 508
400 V (pollution degree 3) according to IEC 60947-5-1 400 V (pollution degree 3) conforming to IEC 60947-5-1 400 V (pollution degree 3) according to IEC 60947-5-1 400 V (pollution degree 3) according to IEC 60947-5-1
300 V (pollution degree 3) according to CSA C22.2 No 14 300 V (pollution degree 3) conforming to CSA C22.2 No 14 300 V (pollution degree 3) according to CSA C22.2 No 14 300 V (pollution degree 3) according to CSA C22.2 No 14
maximum resistance across terminals 25 MΩ conforming to IEC 60255-7 Safety Class 3 25 MOhm conforming to IEC 60255-7 category 3 25 MΩ conforming to IEC 60255-7 Safety Class 3 25 MΩ conforming to IEC 60255-7 Safety Class 3
Rated impulse withstand voltage [Uimp] 4 kV according to IEC 60664 4 kV conforming to IEC 60664 4 kV according to IEC 60664 4 kV according to IEC 60664
4 kV according to IEC 60947-1 4 kV conforming to IEC 60947-1 4 kV according to IEC 60947-1 4 kV according to IEC 60947-1
Short circuit protection 6 A fuse fuse, type gG 6 A cartridge fuse, type gG 6 A fuse fuse, type gG 6 A fuse fuse, type gG
Electrical life 5000000 cycles, DC-13, 120 V, 1 W, operational rating <60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13, 120 V, 1 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 5000000 cycles, DC-13, 120 V, 1 W, operational rating <60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13, 5000000 cycles, DC-13, 120 V, 1 W, operational rating <60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13,
5000000 cycles, DC-13, 24 V, 3 W, operational rating Value <60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13, 24 V, 3 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 24 V, 3 W, operational rating Value <60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 24 V, 3 W, operational rating Value <60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C
5000000 cycles, DC-13, 48 V, 2 W, operating rating <60 cycles/min, duty factor: 0.5 conforming to IEC 60947- 5-1 Appendix C 5000000 cycles, DC-13, 48 V, 2 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 5000000 cycles, DC-13, 48 V, 2 W, operating rating <60 cycles/min, duty factor: 0.5 conforming to IEC 60947- 5-1 Appendix C 5000000 cycles, DC-13, 48 V, 2 W, operating rating <60 cycles/min, duty factor: 0.5 conforming to IEC 60947- 5-1 Appendix C
Mechanical life 5000000 times 5000000 cycles 5000000 times 5000000 times
width 30 mm 30 mm 30 mm 30 mm
high 70.4 mm 70.4 mm 70.4 mm 182 mm
depth 16 mm 16 mm 16 mm 16 mm
Product Weight 0.08 kg 0.08 kg 0.08kg 0.08kg
Environment
impact resistance 25 gn for 18 ms conforming to IEC 60068-2-27 25 gn for 18 ms conforming to IEC 60068-2-27 25 gn for 18 ms conforming to IEC 60068-2-27 25 gn for 18 ms conforming to IEC 60068-2-27
Anti-vibration 5 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 5 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 5 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 5 gn (f= 10…500 Hz) conforming to IEC 60068-2-6
IP protection class “IP65” according to IEC 60529 IP65 conforming to IEC 60529 “IP65” complies with screwed “IP65” complies with screwed
IK protection class IK04 conforms to EN 50102 IK04 conforming to EN 50102 IK04 conforms to EN 50102 IK04 conforms to EN 50102
Electric Shock Protection Level Class II conforms to IEC 61140 Class II conforming to IEC 61140 Class II conforms to IEC 61140 Class II conforms to IEC 61140
Class II conforms to NF C 20-030 Class II conforming to NF C 20-030 Class II conforms to NF C 20-030 Class II conforms to NF C 20-030
operating temperature -25…70°C -25…70 °C -25…70°C -25…70°C
storage environment temperature -40…70°C -40…70 °C -40…70°C -40…70°C
Protective treatment TC TC TC TC
certified product CSA CSA UL CCC
CCC CCC CCC UL
UL UL CSA CSA
Standards compliant CSA C22.2 No 14 UL 508 UL 508 EN/IEC 60204-1
UL 508 EN/IEC 60947-5-1 CSA C22.2 No 14 UL 508
EN/IEC 60204-1 CSA C22.2 No 14 EN/IEC 60947-5-1 CSA C22.2 No 14
EN/IEC 60947-5-1 EN/IEC 60204-1 EN/IEC 60204-1 EN/IEC 60947-5-1
Packaging unit
Unit Type of Package 1 PCE PCE PCE PCE
Number of Units in Package 1 1 1 1 1
Package 1 Height 0.693cm 2.0 cm 2.0cm 1.6cm
Package 1 Width 17.422 cm 13.0 cm 13.0cm 15.0cm
Package 1 Length 17.803 cm 13.0 cm 12.0cm 18.2 cm
Package 1 Weight 120.0g 179.0 g 117.0g 114.0g
Unit Type of Package 2 S02 PAL S02 S02
Number of Units in Package 2 30 320 480 480
Package 2 Height 15.0cm 60.0 cm 15cm 15cm
Package 2 Width 30.0cm 80.0 cm 30cm 30cm
Package 2 Length 40.0cm 320.0 cm 40cm 40cm
Package 2 Weight 4.051kg 57.28 kg 56.8kg 55.36kg
Unit Type of Package 3 S03 P06 P06
Number of Units in Package 3 40 3840 3840
Package 3 Height 30.0 cm 75cm 75cm
Package 3 Width 30.0 cm 40cm 40cm
Package 3 Length 40.0 cm 80cm 80cm
Package 3 Weight 7.993 kg 474.28 kg 462.76kg
Contract warranty
Warranty 18 months 18 months 18 months 18 months

 

 

Main information
Part Number XCMN2107L1 XCMN2110L1 XCMN2115L1 XCMN2121L1
Product Series Telemecanique Limit switches XC Standard Telemecanique Limit switches XC Standard Telemecanique Limit switches XC Standard Telemecanique Limit switches XC Standard
Serial Number Standard type Standard type Standard type Standard type
product type Limit switch Limit switch Limit switch Limit switch
product short name XCMN XCMN XCMN XCMN
sensor design Miniature Miniature Miniature Miniature
ontology type Fixed Fixed Fixed Fixed
Control head type Universal head Direct acting head Swivel head Direct acting head
Material Plastic Plastic Plastic Plastic
body material Plastic Plastic Plastic Plastic
head material Zamak Zamak Zamak Zamak
fixed mode By ontology By ontology By ontology By ontology
Operation head movement Universal Linear To rotate Linear
Operating head type Spring return, spring bar with thermoplastic ends Spring return direct acting metal Spring Return Roller Rocker Thermoplastic Spring Return Roller Direct Acting Thermoplastic
method type Universal motion Vertical movement, one-way Lateral movement, 2-way Lateral movement, one-way
number of poles 2 2 2 2
contact type 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO
contact action Momentary Momentary Momentary Momentary
Additional information
Track 24/31 mm
switch trigger Any moving parts The end 30° lip 30° lip
Electrical connections Fixed cable Fixed cable Fixed cable Fixed cable
cable length 1 m 1 m 1 m 1 m
Cable composition 4 x 0.75 mm² 4 x 0.75 mm² 4 x 0.75 mm² 4 x 0.75 mm²
wire insulation PvR PvR PvR PvR
Type of contact wire insulation Zb Zb Zb Zb
force open None Have Have Have
force open minimum force 42.5N 0.5N 12.5N
Minimum trip force 0.1N 8.5N 0.1N 2.5N
Minimum braking speed 0.01 m/min
operating speed 1 m/s 0.5 m/s 1.5 m/s 1 m/s
Contact wire regulation grade B300, AC-15 (Ue = 240 V), Ie = 1.5 A conforming to EN/IEC 60947-5-1 Appendix A R300, DC- B300, AC-15 (Ue = 240 V), Ie = 1.5 A conforming to EN/IEC 60947-5-1 Appendix A R300, DC- B300, AC-15 (Ue = 240 V), Ie = 1.5 A conforming to EN/IEC 60947-5-1 Appendix A R300, DC- B300, AC-15 (Ue = 240 V), Ie = 1.5 A conforming to EN/IEC 60947-5-1 Appendix A R300, DC-
13 (Ue = 250 V), Ie = 0.1 A conforming to EN/IEC 60947-5 -1 Appendix A 13 (Ue = 250 V), Ie = 0.1 A conforming to EN/IEC 60947-5 -1 Appendix A 13 (Ue = 250 V), Ie = 0.1 A conforming to EN/IEC 60947-5 -1 Appendix A 13 (Ue = 250 V), Ie = 0.1 A conforming to EN/IEC 60947-5 -1 Appendix A
Rated insulation voltage [Ui] 300 V (pollution degree 3) according to UL 508 300 V (pollution degree 3) according to UL 508 300 V (pollution degree 3) according to UL 508 300 V (pollution degree 3) according to UL 508
400 V (pollution degree 3) according to IEC 60947-5-1 400 V (pollution degree 3) according to IEC 60947-5-1 400 V (pollution degree 3) according to IEC 60947-5-1 400 V (pollution degree 3) according to IEC 60947-5-1
300 V (pollution degree 3) according to CSA C22.2 No 14 300 V (pollution degree 3) according to CSA C22.2 No 14 300 V (pollution degree 3) according to CSA C22.2 No 14 300 V (pollution degree 3) according to CSA C22.2 No 14
Maximum resistance across terminals 25 MΩ conforming to IEC 60255-7 Safety Class 3 25 MΩ conforming to IEC 60255-7 Safety Class 3 25 MΩ conforming to IEC 60255-7 Safety Class 3 25 MΩ conforming to IEC 60255-7 Safety Class 3
Rated impulse withstand voltage [Uimp] 4 kV according to IEC 60664 4 kV according to IEC 60664 4 kV according to IEC 60664 4 kV according to IEC 60664
4 kV according to IEC 60947-1 4 kV according to IEC 60947-1 4 kV according to IEC 60947-1 4 kV according to IEC 60947-1
Short circuit protection 6 A fuse fuse, type gG 6 A fuse fuse, type gG 6 A fuse fuse, type gG 6 A fuse fuse, type gG
Electrical life 5000000 cycles, DC-13, 120 V, 1 W, operational rating <60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13, 5000000 cycles, DC-13, 120 V, 1 W, operational rating <60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13, 5000000 cycles, DC-13, 120 V, 1 W, operational rating <60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13, 5000000 cycles, DC-13, 120 V, 1 W, operational rating <60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13,
24 V, 3 W, operational rating Value <60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 24 V, 3 W, operational rating Value <60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 24 V, 3 W, operational rating Value <60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 24 V, 3 W, operational rating Value <60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C
5000000 cycles, DC-13, 48 V, 2 W, operating rating <60 cycles/min, duty factor: 0.5 conforming to IEC 60947- 5-1 Appendix C 5000000 cycles, DC-13, 48 V, 2 W, operating rating <60 cycles/min, duty factor: 0.5 conforming to IEC 60947- 5-1 Appendix C 5000000 cycles, DC-13, 48 V, 2 W, operating rating <60 cycles/min, duty factor: 0.5 conforming to IEC 60947- 5-1 Appendix C 5000000 cycles, DC-13, 48 V, 2 W, operating rating <60 cycles/min, duty factor: 0.5 conforming to IEC 60947- 5-1 Appendix C
Mechanical life 5000000 times 5000000 times 5000000 times 5000000 times
width 30 mm 30 mm 30 mm 30 mm
high 168 mm 60 mm 94mm 79 mm
depth 16 mm 16 mm 16 mm 16 mm
product weight 0.085 kg 0.08kg 0.1kg 0.09 kg
Environment
impact resistance 25 gn for 18 ms conforming to IEC 60068-2-27 25 gn for 18 ms conforming to IEC 60068-2-27 25 gn for 18 ms conforming to IEC 60068-2-27 25 gn for 18 ms conforming to IEC 60068-2-27
Anti-vibration 5 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 5 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 5 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 5 gn (f= 10…500 Hz) conforming to IEC 60068-2-6
IP protection class “IP65” complies with screwed “IP65” complies with screwed “IP65” complies with screwed “IP65” complies with screwed
IK protection class IK04 conforms to EN 50102 IK04 conforms to EN 50102 IK04 conforms to EN 50102 IK04 conforms to EN 50102
Electric Shock Protection Level Class II conforms to IEC 61140 Class II conforms to IEC 61140 Class II conforms to IEC 61140 Class II conforms to IEC 61140
Class II conforms to NF C 20-030 Class II conforms to NF C 20-030 Class II conforms to NF C 20-030 Class II conforms to NF C 20-030
operating temperature -25…70°C -25…70°C -25…70°C -25…70°C
storage environment temperature -40…70°C -40…70°C -40…70°C -40…70°C
Protective treatment TC TC TC TC
certified product CSA CSA CSA UL
CCC CCC UL CSA
UL UL CCC CCC
Standards compliant CSA C22.2 No 14 EN/IEC 60947-5-1 EN/IEC 60204-1 CSA C22.2 No 14
EN/IEC 60947-5-1 CSA C22.2 No 14 UL 508 EN/IEC 60204-1
EN/IEC 60204-1 EN/IEC 60204-1 CSA C22.2 No 14 EN/IEC 60947-5-1
UL 508 UL 508 EN/IEC 60947-5-1 UL 508
Packaging unit
Unit Type of Package 1 PCE PCE PCE PCE
Number of Units in Package 1 1 1 1 1
Package 1 Height 1.7cm 2.5cm 3.3cm 3.424 cm
Package 1 Width 16.7cm 19.0cm 17.0cm 17.425 cm
Package 1 Length 15.0cm 23.0cm 21.0cm 17.808 cm
Package 1 Weight 119.0g 108.0g 152.0g 120.0g
Unit Type of Package 2 S03 S02 S02 S02
Number of Units in Package 2 80 30 20 30
Package 2 Height 30cm 15cm 15.0cm 15cm
Package 2 Width 30cm 30cm 30.0cm 30cm
Package 2 Length 40cm 40cm 40.0cm 40cm
Package 2 Weight 10.233kg 3.863kg 3.615 kg 4.29kg
Unit Type of Package 3 PAL P06 P06 P06
Number of Units in Package 3 640 480 320 480
Package 3 Height 77.0cm 75cm 80.0cm 75cm
Package 3 Width 80.0cm 60cm 80.0cm 60cm
Package 3 Length 60.0cm 80cm 60.0cm 80cm
Package 3 Weight 107.52kg 68.8kg 64.42 kg 83kg
Contract warranty
Warranty 18 months 18 months 18 months 18 months

 

 

Main information
Part Number XCMN2159L1 XCMN2145L1
Product Series Telemecanique Limit switches XC Standard Telemecanique Limit switches XC Standard
Serial Number Standard type Standard type
product type Limit switch Limit switch
product short name XCMN XCMN
sensor design Miniature Miniature
ontology type Fixed Fixed
Control head type Swivel head Swivel head
Material Plastic Plastic
body material Plastic Plastic
head material Zamak Zamak
fixed mode By ontology By ontology
Operation head movement To rotate To rotate
Operating head type Spring Return, Round Rod Rocker Thermoplastic Round Rod 6 mm, L = 200 mm Spring Return Roller Rocker Thermoplastic Variable Length
method type Lateral movement Lateral movement, 2-way
number of poles 2 2
contact type 1 NC + 1 NO 1 NC + 1 NO
contact action Momentary Momentary
Additional information
switch trigger Any moving parts 30° lip
Electrical connections Fixed cable Fixed cable
cable length 1 m 1 m
Cable composition 4 x 0.75 mm² 4 x 0.75 mm²
wire insulation PvR PvR
Type of contact wire insulation Zb Zb
force open None Have
force open minimum force 0.5N
Minimum trip force 0.1N 0.1N
operating speed 1.5 m/s 1.5 m/s
Contact wire regulation grade B300, AC-15 (Ue = 240 V), Ie = 1.5 A conforming to EN/IEC 60947-5-1 Appendix A R300, DC- B300, AC-15 (Ue = 240 V), Ie = 1.5 A conforming to EN/IEC 60947-5-1 Appendix A R300, DC-
13 (Ue = 250 V), Ie = 0.1 A conforming to EN/IEC 60947-5 -1 Appendix A 13 (Ue = 250 V), Ie = 0.1 A conforming to EN/IEC 60947-5 -1 Appendix A
Rated insulation voltage [Ui] 300 V (pollution degree 3) according to UL 508 300 V (pollution degree 3) according to UL 508
400 V (pollution degree 3) according to IEC 60947-5-1 400 V (pollution degree 3) according to IEC 60947-5-1
300 V (pollution degree 3) according to CSA C22.2 No 14 300 V (pollution degree 3) according to CSA C22.2 No 14
Maximum resistance across terminals 25 MΩ conforming to IEC 60255-7 Safety Class 3 25 MΩ conforming to IEC 60255-7 Safety Class 3
Rated impulse withstand voltage [Uimp] 4 kV according to IEC 60664 4 kV according to IEC 60664
4 kV according to IEC 60947-1 4 kV according to IEC 60947-1
Short circuit protection 6 A fuse fuse, type gG 6 A fuse fuse, type gG
Electrical life 5000000 cycles, DC-13, 120 V, 1 W, operational rating <60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13, 5000000 cycles, DC-13, 120 V, 1 W, operational rating <60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13,
24 V, 3 W, operational rating Value <60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 24 V, 3 W, operational rating Value <60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C
5000000 cycles, DC-13, 48 V, 2 W, operating rating <60 cycles/min, duty factor: 0.5 conforming to IEC 60947- 5-1 Appendix C 5000000 cycles, DC-13, 48 V, 2 W, operating rating <60 cycles/min, duty factor: 0.5 conforming to IEC 60947- 5-1 Appendix C
Mechanical life 5000000 times 5000000 times
width 30 mm 30 mm
high 232 mm 143 mm
depth 16 mm 16 mm
product weight 0.08 kg 0.105 kg
Environment
impact resistance 25 gn for 18 ms conforming to IEC 60068-2-27 25 gn for 18 ms conforming to IEC 60068-2-27
Anti-vibration 5 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 5 gn (f= 10…500 Hz) conforming to IEC 60068-2-6
IP protection class “IP65” complies with screwed “IP65” complies with screwed
IK protection class IK04 conforms to EN 50102 IK04 conforms to EN 50102
Electric Shock Protection Level Class II conforms to IEC 61140 Class II conforms to IEC 61140
Class II conforms to NF C 20-030 Class II conforms to NF C 20-030
operating temperature -25…70°C -25…70°C
storage environment temperature -40…70°C -40…70°C
Protective treatment TC TC
certified product UL UL
CCC CSA
CSA CCC
Standards compliant UL 508 UL 508
CSA C22.2 No 14 EN/IEC 60947-5-1
EN/IEC 60947-5-1 CSA C22.2 No 14
EN/IEC 60204-1 EN/IEC 60204-1
Packaging unit
Unit Type of Package 1 PCE PCE
Number of Units in Package 1 1 1
Package 1 Height 4.5cm 3.5cm
Package 1 Width 23.0cm 13cm
Package 1 Length 10.0cm 14cm
Package 1 Weight 162.0g 160g
Unit Type of Package 2 S03 P06
Number of Units in Package 2 50 160
Package 2 Height 30cm 75cm
Package 2 Width 30cm 60cm
Package 2 Length 40cm 80cm
Package 2 Weight 8.813 kg 50.6 kg
Unit Type of Package 3 P06
Number of Units in Package 3 400
Package 3 Height 75cm
Package 3 Width 60cm
Package 3 Length 80cm
Package 3 Weight 89.8kg
Contract warranty
Warranty 18 months 18 months
Weight N/A
Dimensions N/A
Model

, , , , , , , , ,