Limit Switches OsiSence XC Standard – ZCKJ – Standard Environment – With Force Open – Schneider Limit Switches

$ 24.15$ 150.88

SKU: N/A

Specifications

Main information
Part Number ZCKJ121H29 ZCKJD39H29 ZCKJ9H29 ZCKJ15
Product Series Telemecanique Limit switches XC Standard Telemecanique Limit switches XC Standard Telemecanique Limit switches XC Standard Telemecanique Limit switches XC Standard
Serial Number Standard type Standard type Standard type Standard format
product type Limit switch body Limit switch body Limit switch body Limit switch body
product short name ZCKJ ZCKJ ZCKJ ZCKJ
ontology type Fixed Fixed Fixed Fixed
The scope of products XCKJ XCKJ XCKJ XCKJ
connected head ZCKE67 ZCKE21 ZCKE05 ZCKE629
ZCKE66 ZCKE67 ZCKE66 ZCKE63
ZCKE61 ZCKE64 ZCKE06 ZCKE62
ZCKE06 ZCKE62 ZCKE619 ZCKE619
ZCKE62 ZCKE629 ZCKE64 ZCKE21
ZCKE619 ZCKE63 ZCKE61 ZCKE05
ZCKE23 ZCKE619 ZCKE62 ZCKE23
ZCKE65 ZCKE65 ZCKE63 ZCKE61
ZCKE08 ZCKE23 ZCKE629 ZCKE06
ZCKE05 ZCKE66 ZCKE21 ZCKE65
ZCKE64 ZCKE05 ZCKE67 ZCKE08
ZCKE63 ZCKE61 ZCKE23 ZCKE64
ZCKE629 ZCKE06 ZCKE65
ZCKE21 ZCKE08 ZCKE08
body material Metal Metal Metal Metal
cable entry hole 1 for M20x1.6 cable gland 1 for M20x1.6 cable gland 1 for M20x1.6 cable gland 1 entry tapped for Pg 13.5 cable gland
number of poles 2 3 2 2
contact type 1 NC + 1 NO 2 NC + 1 NO 2 NC 1 NC + 1 NO
contact action Momentary Momentary Momentary Snap action
Step count 1 1 position 1 1 position 1 1 position 1 1 position
contact material Silver plated contacts Silver plated contacts Silver plated contacts Gold plated contacts
Additional information
local display Have None None Without
Electrical connections Screw clamp terminal, clamping capacity: 1 x 0.34…2 x 1.5 mm² Screw clamp terminal, clamping capacity: 1 x 0.34…2 x 0.75 mm² Screw clamp terminal, clamping capacity: 1 x 0.34…2 x 1.5 mm² Screw-clamp terminals 1 x 0.34…2 x 1.5 mm²
force open Have Have Have With
minimum braking speed 0.01 m/min 0.01 m/min 0.01 m/min 0.01 m/min
Rated operating current [Ie] 3 A at 240 V, AC-15, A300 conforming to EN/IEC 60947-5-1 Appendix A 1.5 A at 240 V, AC-15, B300 conforming to EN/IEC 60947-5-1 Appendix A 3 A at 240 V, AC-15, A300 conforming to EN/IEC 60947-5-1 Appendix A 3 A 240 V, AC-15, A300 EN/IEC 60947-5-1 appendix A
0.27 A at 250 V, DC-13, Q300 conforming to EN/IEC 60947-5-1 Appendix A 0.1 A at 250 V, DC-13, R300 conforming to EN/IEC 60947-5-1 Appendix A 0.27 A at 250 V, DC-13, Q300 conforming to EN/IEC 60947-5-1 Appendix A 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 appendix A
Conventional enclosed heating current [Ithe] 10A 6A 10A 10:00 AM
Rated insulation voltage [Ui] 500 V (pollution degree 3) conforming to IEC 60947-1 for contact modules 400 V (pollution degree 3) conforming to IEC 60947-1 for contact blocks 500 V (pollution degree 3) conforming to IEC 60947-1 for contact block 500 V 3)IEC 60947-1 contact block
300 V conforming to CSA C22.2 No 14 for contact modules 300 V conforming to CSA C22.2 No 14 for contact blocks 300 V conforming to CSA C22.2 No 14 for contact block 300 VCSA C22.2 No 14 contact block
300 V conforming to UL 508 for contact modules 300 V conforming to UL 508 for contact blocks 300 V conforming to UL 508 for contact block 300 VUL 508 contact block
50 V conforming to IEC 60947-1 for indicator modules
Maximum resistance across terminals 0.25 mΩ conforming to IEC 60255-7 Safety Class 3 0.25 mΩ conforming to IEC 60255-7 Safety Class 3 0.25 mΩ conforming to IEC 60255-7 Safety Class 3 0.25 mOhm IEC 60255-7 category 3
Rated impulse withstand voltage [Uimp] 6 kV according to IEC 60664 6 kV according to IEC 60664 4 kV according to IEC 60664 6 kV IEC 60664
6 kV according to IEC 60947-1 6 kV according to IEC 60947-1 4 kV according to IEC 60947-1 6 kV IEC 60947-1
Short circuit protection 10 A fuse fuse, type gG 10 A fuse fuse, type gG 6 A fuse fuse, type gG 10 A cartridge fuse gG
Electrical life 5000000 cycles, DC-13 120 V, 4 W, operating rating<60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13 5000000 cycles, DC-13 120 V, 7 W, operating rating<60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13 5000000 cycles, DC-13 120 V, 1 W, operating rating<60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13 5000000 cycles, DC-13 120 V, 4 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C
24 V, 10 W, operating rating< 60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 24 V, 13 W, operating rating< 60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 24 V, 3 W, operating rating< 60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13 24 V, 10 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C
5000000 cycles, DC-13 48 V, 7 W, operating rating <60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Appendix C 5000000 cycles, DC-13 48 V, 9 W, operating rating <60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Appendix C 5000000 cycles, DC-13 48 V, 2 W, operating rating <60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Appendix C 5000000 cycles, DC-13 48 V, 7 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C
loop type Indicator module 2 LED DC, 24 V (20…30 V) Lifetime: 100000 hours and reverse polarity protection
width 40 mm 52 mm 40 mm 1.57 in (40 mm)
high 77 mm 72 mm 77 mm 3.03 in (77 mm)
depth 44 mm 30 mm 44 mm 1.73 in (44 mm)
product weight 0.31kg 0.21kg 0.31kg 0.68 lb(US) (0.31 kg)
ISO n°1 terminals (13-14)NO (21-22)NC (13-14)NO (21-22)NC
(21-22)NC (13-14)NO (21-22)NC (13-14)NO
(31-32)NC
Environment
IP rating IP66 IP66 IP66 IP66
IK level IK07 IK05 IK07 IK07
ambient temperature -25…70 °C for standard environments -25…70 °C for standard environment -25…70 °C for standard environment -13…158 °F (-25…70 °C) standard environment
10…120 °C for high temperatures
-40…70 °C for low temperatures
storage environment temperature -40…120°C -40…70°C -40…70°C -40…158 °F (-40…70 °C)
environmental features Low temperature Standard environment Standard environment Standard environment
standard environment
high temperature
Ordering and shipping details
Category 22411-LIMIT SWITCHES,IEC,XCKJ
Discount Schedule T
GTIN 3.38911E+12
Returnability No
Country of origin FR
Packaging unit
Unit Type of Package 1 PCE PCE PCE PCE
Number of Units in Package 1 1 1 1 1
Package 1 Height 4.4cm 4.5cm 4.000 cm 1.73 in (4.4 cm)
Package 1 Width 4.7cm 4.7cm 4.600 cm 1.85 in (4.7 cm)
Package 1 Length 9.1 cm 8.7cm 7.800 cm 3.58 in (9.1 cm)
Package 1 Weight 297.0g 289.0g 286.000g 10.16 oz (288 g)
Unit Type of Package 2 S01 S02 S02 S02
Number of Units in Package 2 15 Twenty four Twenty four 24
Package 2 Height 15.0cm 15.0cm 15.000 cm 5.91 in (15 cm)
Package 2 Width 15.0cm 30.0cm 30.000 cm 11.81 in (30 cm)
Package 2 Length 40.0cm 40.0cm 40.000 cm 15.75 in (40 cm)
Package 2 Weight 4.641 kg 7.461 kg 7.156 kg 15.92 lb(US) (7.219 kg)
P06
384
77.0cm
80.0cm
60.0cm
125.604kg
Contract warranty
Warranty 18 months 18 months 18 months 18 months

 

 

 

Main information
Part Number ZCKJ1 ZCKJ1C ZCKJ5 ZCKJ7
Product Series Telemecanique Limit switches XC Standard Telemecanique Limit switches XC Standard Telemecanique Limit switches XC Standard Telemecanique Limit switches XC Standard
Serial Number Standard type Standard type Standard type Standard type
product type Limit switch body Limit switch body Limit switch body Limit switch body
product short name ZCKJ ZCKJ ZCKJ ZCKJ
ontology type Fixed Fixed Fixed Fixed
The scope of products XCKJ XCKJ XCKJ XCKJ
connected head ZCKE619 ZCKE65 ZCKE62 ZCKE05
ZCKE64 ZCKE06 ZCKE64 ZCKE64
ZCKE629 ZCKE61 ZCKE619 ZCKE08
ZCKE65 ZCKE08 ZCKE65 ZCKE65
ZCKE63 ZCKE21 ZCKE23 ZCKE66
ZCKE67 ZCKE23 ZCKE08 ZCKE06
ZCKE06 ZCKE05 ZCKE629 ZCKE629
ZCKE05 ZCKE67 ZCKE63 ZCKE61
ZCKE21 ZCKE66 ZCKE66 ZCKE23
ZCKE61 ZCKE629 ZCKE06 ZCKE63
ZCKE08 ZCKE619 ZCKE61 ZCKE619
ZCKE23 ZCKE64 ZCKE05 ZCKE21
ZCKE66 ZCKE62 ZCKE67 ZCKE67
ZCKE62 ZCKE63 ZCKE21 ZCKE62
body material Metal Metal Metal Metal
cable entry hole 1 suitable for Pg13.5 cable sealing interface 1 suitable for Pg13.5 cable sealing interface 1 suitable for Pg13.5 cable sealing interface 1 suitable for Pg13.5 cable sealing interface
number of poles 2 2 2 2
contact type 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO 2 NC
contact action Momentary Momentary Slow break, break before make Slow interrupt while
Step count 1 1 position 1 1 position 1 1 position 1 1 position
contact material Silver plated contacts Silver plated contacts Silver plated contacts Silver plated contacts
Additional information Additional information Additional information
local display None None None None
Electrical connections Screw clamp terminal, clamping capacity: 1 x 0.34…2 x 1.5 mm² Screw clamp terminal, clamping capacity: 1 x 0.34…2 x 1.5 mm² Screw clamp terminal, clamping capacity: 1 x 0.5…2 x 2.5 mm² Screw clamp terminal, clamping capacity: 1 x 0.5…2 x 2.5 mm²
force open Have Have Have Have
minimum braking speed 0.01 m/min 0.01 m/min 6 m/min 6 m/min
Rated operating current [Ie] 3 A at 240 V, AC-15, A300 conforming to EN/IEC 60947-5-1 Appendix A 3 A at 240 V, AC-15, A300 conforming to EN/IEC 60947-5-1 Appendix A 3 A at 240 V, AC-15, A300 conforming to EN/IEC 60947-5-1 Appendix A 3 A at 240 V, AC-15, A300 conforming to EN/IEC 60947-5-1 Appendix A
0.27 A at 250 V, DC-13, Q300 conforming to EN/IEC 60947-5-1 Appendix A 0.27 A at 250 V, DC-13, Q300 conforming to EN/IEC 60947-5-1 Appendix A 0.27 A at 250 V, DC-13, Q300 conforming to EN/IEC 60947-5-1 Appendix A 0.27 A at 250 V, DC-13, Q300 conforming to EN/IEC 60947-5-1 Appendix A
Conventional enclosed heating current [Ithe] 10A 10A 10A 10A
Rated insulation voltage [Ui] 500 V (pollution degree 3) conforming to IEC 60947-1 for contact block 500 V (pollution degree 3) conforming to IEC 60947-1 for contact block 500 V (pollution degree 3) conforming to IEC 60947-1 for contact block 500 V (pollution degree 3) conforming to IEC 60947-1 for contact block
300 V conforming to CSA C22.2 No 14 for contact block 300 V conforming to CSA C22.2 No 14 for contact block 300 V conforming to CSA C22.2 No 14 for contact block 300 V conforming to CSA C22.2 No 14 for contact block
300 V conforming to UL 508 for contact block 300 V conforming to UL 508 for contact block 300 V conforming to UL 508 for contact block 300 V conforming to UL 508 for contact block
Maximum resistance across terminals 0.25 mΩ conforming to IEC 60255-7 Safety Class 3 0.25 mΩ conforming to IEC 60255-7 Safety Class 3 0.25 mΩ conforming to IEC 60255-7 Safety Class 3 0.25 mΩ conforming to IEC 60255-7 Safety Class 3
Rated impulse withstand voltage [Uimp] 6 kV according to IEC 60664 6 kV according to IEC 60664 0.8 kV according to IEC 60664 6 kV according to IEC 60664
6 kV according to IEC 60947-1 6 kV according to IEC 60947-1 0.8 kV according to IEC 60947-1 6 kV according to IEC 60947-1
Short circuit protection 10 A fuse fuse, type gG 10 A fuse fuse, type gG 4 A fuse fuse, type gG 10 A fuse fuse, type gG
Electrical life 5000000 cycles, DC-13 120 V, 4 W, operating rating<60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13 5000000 cycles, DC-13 120 V, 4 W, operating rating<60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13 5000000 cycles, DC-13 24 V, 10 W, operating rating<60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13 5000000 cycles, DC-13 120 V, 4 W, operating rating<60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13
24 V, 10 W, operating rating< 60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 24 V, 10 W, operating rating< 60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 48 V, 7 W, operating rating< 60 times/min, load factor: 0.5 conforming to IEC 60947-5-1 Appendix C 24 V, 10 W, operating rating< 60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C
5000000 cycles, DC-13 48 V, 7 W, operating rating <60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Appendix C 5000000 cycles, DC-13 48 V, 7 W, operating rating <60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Appendix C 5000000 cycles, DC-13 48 V, 7 W, operating rating <60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Appendix C
loop type Indicator light module 2 neon lights AC, 110/120 V (95…130 V) Service life: 20000 hours Indicator light module 2 neon lights AC, 110/120 V (95…130 V) Service life: 20000 hours
width 40cm 43 mm 40 mm 40 mm
high 81.5 cm 84mm 89mm 77 mm
depth 44cm 36mm 44 mm 44 mm
product weight 0.34kg 0.34kg 0.32kg 0.31kg
ISO n°1 terminals (11-12)NC (11-12)NC (13-14)NO (21-22)NC
(13-14)NO (13-14)NO (21-22)NC (11-12)NC
Environment
IP rating IP66 IP66 IP66 IP66
IK level IK07 IK07 IK07 IK07
ambient temperature -25…70 °C for standard environment -25…70 °C for standard environment -25…70 °C for standard environment -25…70 °C for standard environments
10…120 °C for high temperatures
-40…70 °C for low temperatures
storage environment temperature -40…70°C -40…70°C -40…70°C -40…120°C
environmental features Standard environment Standard environment Standard environment High temperature
standard environment
low temperature
Packaging unit
Unit Type of Package 1 PCE PCE PCE PCE
Number of Units in Package 1 1 1 1 1
Package 1 Height 8.7cm 4.15cm 4cm 4.0cm
Package 1 Width 4.2 cm 4.5cm 8.5cm 8.5cm
Package 1 Length 4.6cm 8.7cm 4.5cm 4.5cm
Package 1 Weight 300.0g 281.0g 285g 284.0g
Unit Type of Package 2 S02 PAL S02 S02
Number of Units in Package 2 Twenty four 1152 Twenty four Twenty four
Package 2 Height 15.0cm 75.0cm 15cm 15.0cm
Package 2 Width 30.0cm 60.0cm 30cm 30.0cm
Package 2 Length 40.0cm 80.0cm 40cm 40.0cm
Package 2 Weight 7.2kg 358.721kg 7.386 kg 7.334 kg
Unit Type of Package 3 PAL CAR
Number of Units in Package 3 384 18
Package 3 Height 77.0cm 14.6 cm
Package 3 Width 60.0cm 16.1 cm
Package 3 Length 80.0cm 20.2 cm
Package 3 Weight 124.836 kg 5.18kg
Contract warranty
Warranty 18 months 18 months 18 months 18 months
Weight N/A
Dimensions N/A
Model

ZCKJ1, ZCKJ121H29, ZCKJ15, ZCKJ1C, ZCKJ5, ZCKJ7, ZCKJ9H29, ZCKJD39H29

Related products