Contact Us:
sales@inosaki.com

Harmony – RE22 – Dual Function Relay – Modular Timer Relays – Schneider Timer Relays

$ 59.11$ 82.34

Specifications

Main
Part Number RE22R1ACMR RE22R1AMR RE22R1KMR
Product Series Harmony Timer Relays Harmony Timer Relays Harmony Timer Relays
product type Dual function relay Dual function relay Single function relay
Solid state output type Relay Relay Relay
product short name RE22 RE22 RE22
Rated output current 8A 8A 5A
Additional information
Contact type and composition 1 C/O timing contact, cadmium free 1 C/O timing contact, cadmium free 1 C/O timing contact, cadmium free
delay type On-delay and off-delay Power on-delay Delay on de-energization
Delay range 3…30 min
1…10 s
30…300 s
10…100 s
3…30 s
30…300 min
30…300 h
0.3…3 s
0.05. ..1 s
3…30 h
3…30 s
30…300 s
10…100 s
0.05…1 s
1…10 s
30…300 h
30…300 min
0.3…3 s
3. ..30 h
3…30 min
10…100 s
1…10 min
1…10 s
0.3…3 s
3…30 s
0.05…1 s
30…300 s
control type Knob
Diagnostic Button
Potentiometer External
Knob
diagnostic button
Knob
Rated supply voltage [Us] 24…240 V AC/DC 50/60 Hz 24…240 V AC/DC 50/60 Hz 24…240 V AC/DC 50/60 Hz
Release input voltage <= 2.4V <= 2.4V <= 2.4V
voltage range 19…30V 19…30V 19…30V
power supply frequency 50…60 Hz +/- 5 % 50…60 Hz +/- 5 % 50…60 Hz +/- 5 %
Wiring capacity Screw terminal, 1 x 0.5…1 x 3.3 mm² (AWG 20…AWG 12) Solid without wire terminal Screw
terminal, 2 x 0.5…2 x 2.5 mm² (AWG 20…AWG 14 ) solid without wire terminal
screw terminal, 1 x 0.2…1 x 2.5 mm² (AWG 24…AWG 14) flexible wire with wire terminal
screw terminal, 2 x 0.2…2 x 1.5 mm² ( AWG 24…AWG 16) flexible wire with wire terminal
Screw terminal, 1 x 0.5…1 x 3.3 mm² (AWG 20…AWG 12) Solid without wire terminal Screw
terminal, 2 x 0.5…2 x 2.5 mm² (AWG 20…AWG 14 ) solid without wire terminal
screw terminal, 1 x 0.2…1 x 2.5 mm² (AWG 24…AWG 14) flexible wire with wire terminal
screw terminal, 2 x 0.2…2 x 1.5 mm² ( AWG 24…AWG 16) flexible wire with wire terminal
Screw terminal, 1 x 0.5…1 x 3.3 mm² (AWG 20…AWG 12) Solid without wire terminal Screw
terminal, 2 x 0.5…2 x 2.5 mm² (AWG 20…AWG 14 ) solid without wire terminal
screw terminal, 1 x 0.2…1 x 2.5 mm² (AWG 24…AWG 14) flexible wire with wire terminal
screw terminal, 2 x 0.2…2 x 1.5 mm² ( AWG 24…AWG 16) flexible wire with wire terminal
Tightening torque 0.6…1 Nm conforming to IEC 60947-1 0.6…1 Nm conforming to IEC 60947-1 0.6…1 Nm conforming to IEC 60947-1
covering material Flame retardant Flame retardant Flame retardant
Repeatability +/- 0.5 % according to IEC 61812-1 +/- 0.5 % according to IEC 61812-1 +/- 0.5 % according to IEC 61812-1
temperature deviation +/- 0.05 %/°C +/- 0.05 %/°C +/- 0.05 %/°C
voltage deviation +/- 0.2 %/V +/- 0.2 %/V +/- 0.2 %/V
Latency Accuracy Settings +/- 10 % of full scale at 25 °C conforming to IEC 61812-1 +/- 10 % of full scale at 25 °C conforming to IEC 61812-1 +/- 10 % of full scale at 25 °C conforming to IEC 61812-1
Control signal pulse width 100 ms with parallel load
30 ms
100 ms with parallel load
30 ms
Insulation resistance 100 MΩ at 500 V DC conforming to IEC 60664-1 100 MΩ at 500 V DC conforming to IEC 60664-1 100 MΩ at 500 V DC conforming to IEC 60664-1
Recovery time 120 ms discharge 120 ms discharge 100 ms discharge
Anti-instantaneous power failure 10ms 10ms 10ms
Power consumption VA 3 VA at 240 V AC 3 VA at 240 V AC 3 VA at 240 V AC
power consumption[W] 1.5 W at 240 V DC 1.5 W at 240 V DC 2 W at 240 V DC
Switching capacity in VA 2000VA 2000VA 1250VA
Minimum switching current [Imin] 10 mA at 5 V DC 10 mA at 5 V DC 10 mA at 5 V DC
Maximum switching current 8A 8A 5A
Maximum Switching Voltage 250 VAC 250 VAC 250 VAC
Electrical life 100000 cycles, 8 A at 250 V, AC-1
100000 cycles, 2 A at 24 V, DC-1
100000 cycles, 8 A at 250 V, AC-1
100000 cycles, 2 A at 24 V, DC-1
100000 cycles, 2 A at 24 V, DC-1
100000 cycles, 5 A at 250 V, AC-1
Mechanical life 10000000 times 10000000 times 10000000 times
Rated impulse withstand voltage 5 kV for 1.2…50 µs conforming to IEC 60664-1 5 kV for 1.2…50 µs conforming to IEC 60664-1 5 kV for 1.2…50 µs conforming to IEC 60664-1
Power on delay 100ms 100ms 200ms
Creepage distance 4 kV/3 conforming to IEC 60664-1 4 kV/3 conforming to IEC 60664-1 4 kV/3 conforming to IEC 60664-1
Type of overvoltage III conforms to IEC 60664-1 III conforms to IEC 60664-1 III conforms to IEC 60664-1
Safe and reliable data B10d = 190000
MTTFd = 205.4 years
MTTFd = 308.2 years
B10d = 280000
MTTFd = 194 years
B10d = 180000
installation location Any position Any position Any position
installation method 35 mm DIN rail conforming to EN/IEC 60715 35 mm DIN rail conforming to EN/IEC 60715 35 mm DIN rail conforming to EN/IEC 60715
LED status Green LED backlight (constant) for dial indicator
yellow LED (constant) for output closing
yellow LED (quick flashing) for output opening timing
yellow LED (slow flashing) for output closing timing
Green LED backlight (constant) for dial indicator
yellow LED (constant) for output closing
yellow LED (quick flashing) for output opening timing
yellow LED (slow flashing) for output closing timing
Green LED Backlight (Constant) for Dial Indicator
Yellow LED (Constant) for Output Closed
Yellow LED (Constant) for Power On
width 22.5 mm 22.5 mm 22.5 mm
Product Weight 0.1 kg 0.1 kg 0.1 kg
environment
Insulation properties 2.5 kV for 1 mA/1 minute at 50 Hz between relay output and supply and basic insulation to IEC 61812-1 2.5 kV for 1 mA/1 minute at 50 Hz between relay output and supply and basic insulation to IEC 61812-1 2.5 kV for 1 mA/1 minute at 50 Hz between relay output and supply and basic insulation to IEC 61812-1
Standards compliant IEC 61812-1
UL 508
UL 508
IEC 61812-1
IEC 61812-1
UL 508
complies with directives 2006/95/EC – Low Voltage Directive
2004/108/EC – Electromagnetic Compatibility
2006/95/EC – Low Voltage Directive
2004/108/EC – Electromagnetic Compatibility
2006/95/EC – Low Voltage Directive
2004/108/EC – Electromagnetic Compatibility
certified product CE
CCC
GL
UL
CSA
EAC
RCM
CE
UL
GL
CCC
EAC
RCM
CSA
CCC
CSA
GL
RCM
CE
EAC
UL
operating temperature -20…60°C -20…60°C -20…60°C
storage environment temperature -40…70°C -40…70°C -40…70°C
IP protection class IP40 housing: conforming to IEC 60529
IP50 front panel: conforming to IEC 60529
IP20 terminals: conforming to IEC 60529
IP40 housing: conforming to IEC 60529
IP50 front panel: conforming to IEC 60529
IP20 terminals: conforming to IEC 60529
IP40 housing: conforming to IEC 60529
IP50 front panel: conforming to IEC 60529
IP20 terminals: conforming to IEC 60529
pollution level 3 Conforming to IEC 60664-1 3 Conforming to IEC 60664-1 3 Conforming to IEC 60664-1
Anti-vibration 20 m/s² (f= 10…150 Hz) conforming to IEC 60068-2-6 20 m/s² (f= 10…150 Hz) conforming to IEC 60068-2-6 20 m/s² (f= 10…150 Hz) conforming to IEC 60068-2-6
impact resistance 15 gn non-operating for 11 ms conforming to IEC 60068-2-27
5 gn operating for 11 ms conforming to IEC 60068-2-27
15 gn non-operating for 11 ms conforming to IEC 60068-2-27
5 gn operating for 11 ms conforming to IEC 60068-2-27
15 gn non-operating for 11 ms conforming to IEC 60068-2-27
5 gn operating for 11 ms conforming to IEC 60068-2-27
Relative humidity 95 % at 25…55 °C 95 % at 25…55 °C 95 % at 25…55 °C
electromagnetic compatibility Electrical fast transient burst immunity test – test level: 1 kV (capacitive connection clip) level 3 conforming to IEC 61000-4-4
surge discharge immunity – test level: 1 kV (differential mode) level 3 conforming to IEC 61000-4-5
Surge Discharge Immunity – Test Level: 2 kV (Common Mode) Level 3 conforming to IEC 61000-4-5
Antistatic Interference – Test Level: 6 kV (Contact Discharge) Level 3 conforming to IEC 61000-4- 2
Anti-static interference – test level: 8 kV (air discharge) level 3 conforms to IEC 61000-4-2
RF electromagnetic field radiation immunity test – test level: 10 V/m (80 MHz…1 GHz) level 3 conforms IEC 61000-4-3
Conducted Immunity – Test Level: 10 V (0.15…80 MHz) Level 3 conforms to IEC 61000-4-6
Fast Burst Transients – Test Level: 2 kV (direct contact) Level 3 conforms to IEC 61000-4-4
Immunity to Voltage Offset – Test Level: 30 % (500 ms) conforming to IEC 61000-4-11
Immunity to Voltage Offset – Test Level: 100 % (20 ms) conforming to IEC 61000-4-11
Electrical fast transient burst immunity test – test level: 1 kV (capacitive connection clip) level 3 conforming to IEC 61000-4-4
surge discharge immunity – test level: 1 kV (differential mode) level 3 conforming to IEC 61000-4-5
Surge Discharge Immunity – Test Level: 2 kV (Common Mode) Level 3 conforming to IEC 61000-4-5
Antistatic Interference – Test Level: 6 kV (Contact Discharge) Level 3 conforming to IEC 61000-4- 2
Anti-static interference – test level: 8 kV (air discharge) level 3 conforms to IEC 61000-4-2
RF electromagnetic field radiation immunity test – test level: 10 V/m (80 MHz…1 GHz) level 3 conforms IEC 61000-4-3
Conducted Immunity – Test Level: 10 V (0.15…80 MHz) Level 3 conforms to IEC 61000-4-6
Fast Burst Transients – Test Level: 2 kV (direct contact) Level 3 conforms to IEC 61000-4-4
Immunity to Voltage Offset – Test Level: 30 % (500 ms) conforming to IEC 61000-4-11
Immunity to Voltage Offset – Test Level: 100 % (20 ms) conforming to IEC 61000-4-11
Electrical fast transient burst immunity test – test level: 1 kV (capacitive connection clip) level 3 conforming to IEC 61000-4-4
surge discharge immunity – test level: 1 kV (differential mode) level 3 conforming to IEC 61000-4-5
Surge Discharge Immunity – Test Level: 2 kV (Common Mode) Level 3 conforming to IEC 61000-4-5
Antistatic Interference – Test Level: 6 kV (Contact Discharge) Level 3 conforming to IEC 61000-4- 2
Anti-static interference – test level: 8 kV (air discharge) level 3 conforms to IEC 61000-4-2
RF electromagnetic field radiation immunity test – test level: 10 V/m (80 MHz…1 GHz) level 3 conforms IEC 61000-4-3
Conducted Immunity – Test Level: 10 V (0.15…80 MHz) Level 3 conforms to IEC 61000-4-6
Fast Burst Transients – Test Level: 2 kV (direct contact) Level 3 conforms to IEC 61000-4-4
Immunity to Voltage Offset – Test Level: 30 % (500 ms) conforming to IEC 61000-4-11
Immunity to Voltage Offset – Test Level: 100 % (20 ms) conforming to IEC 61000-4-11
packaging unit
Unit Type of Package 1 PCE PCE PCE
Number of Units in Package 1 1 1 1
Package 1 Height 2.6cm 2.6cm 2.6cm
Package 1 Width 8.2 cm 8.2 cm 8.2 cm
Package 1 Length 9.5cm 9.5cm 9.5cm
Package 1 Weight 100.0g 92.0g 93g
Unit Type of Package 2 S02 S02
Number of Units in Package 2 40 40
Package 2 Height 15.0cm 15.0cm
Package 2 Width 30.0cm 30.0cm
Package 2 Length 40.0cm 40.0cm
Package 2 Weight 4.405 kg 4.261kg
Unit Type of Package 3 P06 P06
Number of Units in Package 3 640 640
Package 3 Height 50.0cm 75.0cm
Package 3 Width 80.0cm 60.0cm
Package 3 Length 60.0cm 80.0cm
Package 3 Weight 79.78kg 76.676kg
contract warranty
Warranty 18 months 18 months 18 months

 

Main
Part Number RE22R1MLMR RE22R2AMR RE22R2QTMR
Product Series Harmony Timer Relays Harmony Timer Relays Harmony Timer Relays
product type Multifunction relay Dual function relay Single function relay
Solid state output type Relay Relay Relay
product short name RE22 RE22 RE22
Rated output current 8A 8A 8A
Additional information
Contact type and composition 1 C/O timing contact, cadmium free 1 C/O timed contact, cadmium free
1 C/O timed or momentary contact, cadmium free
2 OC timing contacts, cadmium free
delay type Asymmetrical flashing Power on-delay Star-delta
Delay range 0.05…1 s
30…300 min
30…300 h
30…300 s
3…30 h
0.3…3 s
3…30 min
3…30 s
10. ..100 s
1…10 s
0.05…1 s
0.3…3 s
3…30 h
30…300 min
10…100 s
30…300 s
3…30 s
30…300 h
1. ..10 s
3…30 min
1…10 s
3…30 s
10…100 s
30…300 min
0.05…1 s
3…30 min
0.3…3 s
30…300 s
3. ..30 h
30…300 h
control type Knob
Diagnostic Button
Potentiometer External
Knob
Diagnostic Button
Potentiometer External
Knob
diagnostic button
Rated supply voltage [Us] 24…240 V AC/DC 50/60 Hz 24…240 V AC/DC 50/60 Hz 24…240 V AC/DC 50/60 Hz
Release input voltage <= 2.4V <= 2.4V <= 2.4V
voltage range 19…30V 19…30V 19…30V
power supply frequency 50…60 Hz +/- 5 % 50…60 Hz +/- 5 % 50…60 Hz +/- 5 %
Wiring capacity Screw terminal, 1 x 0.5…1 x 3.3 mm² (AWG 20…AWG 12) Solid without wire terminal Screw
terminal, 2 x 0.5…2 x 2.5 mm² (AWG 20…AWG 14 ) solid without wire terminal
screw terminal, 1 x 0.2…1 x 2.5 mm² (AWG 24…AWG 14) flexible wire with wire terminal
screw terminal, 2 x 0.2…2 x 1.5 mm² ( AWG 24…AWG 16) flexible wire with wire terminal
Screw terminal, 1 x 0.5…1 x 3.3 mm² (AWG 20…AWG 12) Solid without wire terminal Screw
terminal, 2 x 0.5…2 x 2.5 mm² (AWG 20…AWG 14 ) solid without wire terminal
screw terminal, 1 x 0.2…1 x 2.5 mm² (AWG 24…AWG 14) flexible wire with wire terminal
screw terminal, 2 x 0.2…2 x 1.5 mm² ( AWG 24…AWG 16) flexible wire with wire terminal
Screw terminal, 1 x 0.5…1 x 3.3 mm² (AWG 20…AWG 12) Solid without wire terminal Screw
terminal, 2 x 0.5…2 x 2.5 mm² (AWG 20…AWG 14 ) solid without wire terminal
screw terminal, 1 x 0.2…1 x 2.5 mm² (AWG 24…AWG 14) flexible wire with wire terminal
screw terminal, 2 x 0.2…2 x 1.5 mm² ( AWG 24…AWG 16) flexible wire with wire terminal
Tightening torque 0.6…1 Nm conforming to IEC 60947-1 0.6…1 Nm conforming to IEC 60947-1 0.6…1 Nm conforming to IEC 60947-1
covering material Flame retardant Flame retardant Flame retardant
Repeatability +/- 0.5 % according to IEC 61812-1 +/- 0.5 % according to IEC 61812-1 +/- 0.5 % according to IEC 61812-1
temperature deviation +/- 0.05 %/°C +/- 0.05 %/°C +/- 0.05 %/°C
voltage deviation +/- 0.2 %/V +/- 0.2 %/V +/- 0.2 %/V
Latency Accuracy Settings +/- 10 % of full scale at 25 °C conforming to IEC 61812-1 +/- 10 % of full scale at 25 °C conforming to IEC 61812-1 +/- 10 % of full scale at 25 °C conforming to IEC 61812-1
Control signal pulse width 100 ms with parallel load
30 ms
100 ms with parallel load
30 ms
Insulation resistance 100 MΩ at 500 V DC conforming to IEC 60664-1 100 MΩ at 500 V DC conforming to IEC 60664-1 100 MΩ at 500 V DC conforming to IEC 60664-1
Recovery time 120 ms discharge 120 ms discharge 120 ms discharge
Anti-instantaneous power failure 10ms 10ms 10ms
Power consumption VA 3 VA at 240 V AC 3 VA at 240 V AC 3 VA at 240 V AC
power consumption[W] 1.5 W at 240 V DC 1.5 W at 240 V DC 1.5 W at 240 V DC
Switching capacity in VA 2000VA 2000VA 2000VA
Minimum switching current [Imin] 10 mA at 5 V DC 10 mA at 5 V DC 10 mA at 5 V DC
Maximum switching current 8A 8A 8A
Maximum Switching Voltage 250 VAC 250 VAC 250 VAC
Electrical life 100000 cycles, 8 A at 250 V, AC-1
100000 cycles, 2 A at 24 V, DC-1
100000 cycles, 8 A at 250 V, AC-1
100000 cycles, 2 A at 24 V, DC-1
100000 cycles, 8 A at 250 V, AC-1
100000 cycles, 2 A at 24 V, DC-1
Mechanical life 10000000 times 10000000 times 10000000 times
Rated impulse withstand voltage 5 kV for 1.2…50 µs conforming to IEC 60664-1 5 kV for 1.2…50 µs conforming to IEC 60664-1 5 kV for 1.2…50 µs conforming to IEC 60664-1
Power on delay 100ms 100ms 100ms
Creepage distance 4 kV/3 conforming to IEC 60664-1 4 kV/3 conforming to IEC 60664-1 4 kV/3 conforming to IEC 60664-1
Type of overvoltage III conforms to IEC 60664-1 III conforms to IEC 60664-1 III conforms to IEC 60664-1
Safe and reliable data MTTFd = 194 years
B10d = 180000
B10d = 200000
MTTFd = 216.8 years
MTTFd = 342.4 years
B10d = 320000
installation location Any position Any position Any position
installation method 35 mm DIN rail conforming to EN/IEC 60715 35 mm DIN rail conforming to EN/IEC 60715 35 mm DIN rail conforming to EN/IEC 60715
LED status Green LED backlight (constant) for dial indicator
yellow LED (constant) for output closing
yellow LED (quick flashing) for output opening timing
yellow LED (slow flashing) for output closing timing
Green LED backlight (constant) for dial indicator
yellow LED (constant) for output closing
yellow LED (quick flashing) for output opening timing
yellow LED (slow flashing) for output closing timing
Green LED backlight (constant) for dial indicator
yellow LED (constant) for output closing
yellow LED (quick flashing) for output opening timing
yellow LED (slow flashing) for output closing timing
width 22.5 mm 22.5 mm 22.5 mm
Product Weight 0.1 kg 0.105kg 0.105kg
environment
Insulation properties 2.5 kV for 1 mA/1 minute at 50 Hz between relay output and supply and basic insulation to IEC 61812-1 2.5 kV for 1 mA/1 minute at 50 Hz between relay output and supply and basic insulation to IEC 61812-1 2.5 kV for 1 mA/1 minute at 50 Hz between relay output and supply and basic insulation to IEC 61812-1
Standards compliant IEC 61812-1
UL 508
UL 508
IEC 61812-1
IEC 61812-1
UL 508
complies with directives 2004/108/EC – Electromagnetic Compatibility
2006/95/EC – Low Voltage Directive
2004/108/EC – Electromagnetic Compatibility
2006/95/EC – Low Voltage Directive
2006/95/EC – Low Voltage Directive
2004/108/EC – Electromagnetic Compatibility
certified product EAC
UL
GL
CSA
RCM
CCC
CE
CE
CCC
GL
UL
RCM
EAC
CSA
CCC
GL
UL
EAC
RCM
CSA
CE
operating temperature -20…60°C -20…60°C -20…60°C
storage environment temperature -40…70°C -40…70°C -40…70°C
IP protection class IP40 housing: conforming to IEC 60529
IP50 front panel: conforming to IEC 60529
IP20 terminals: conforming to IEC 60529
IP40 housing: conforming to IEC 60529
IP20 terminal: conforming to IEC 60529
IP50 cover: conforming to IEC 60529
IP40 housing: conforming to IEC 60529
IP20 terminal: conforming to IEC 60529
IP50 cover: conforming to IEC 60529
pollution level 3 Conforming to IEC 60664-1 3 Conforming to IEC 60664-1 3 Conforming to IEC 60664-1
Anti-vibration 20 m/s² (f= 10…150 Hz) conforming to IEC 60068-2-6 20 m/s² (f= 10…150 Hz) conforming to IEC 60068-2-6 20 m/s² (f= 10…150 Hz) conforming to IEC 60068-2-6
impact resistance 15 gn non-operating for 11 ms conforming to IEC 60068-2-27
5 gn operating for 11 ms conforming to IEC 60068-2-27
15 gn non-operating for 11 ms conforming to IEC 60068-2-27
5 gn operating for 11 ms conforming to IEC 60068-2-27
15 gn non-operating for 11 ms conforming to IEC 60068-2-27
5 gn operating for 11 ms conforming to IEC 60068-2-27
Relative humidity 95 % at 25…55 °C 95 % at 25…55 °C 95 % at 25…55 °C
electromagnetic compatibility Electrical fast transient burst immunity test – test level: 1 kV (capacitive connection clip) level 3 conforming to IEC 61000-4-4
surge discharge immunity – test level: 1 kV (differential mode) level 3 conforming to IEC 61000-4-5
Surge Discharge Immunity – Test Level: 2 kV (Common Mode) Level 3 conforming to IEC 61000-4-5
Antistatic Interference – Test Level: 6 kV (Contact Discharge) Level 3 conforming to IEC 61000-4- 2
Anti-static interference – test level: 8 kV (air discharge) level 3 conforms to IEC 61000-4-2
RF electromagnetic field radiation immunity test – test level: 10 V/m (80 MHz…1 GHz) level 3 conforms IEC 61000-4-3
Conducted Immunity – Test Level: 10 V (0.15…80 MHz) Level 3 conforms to IEC 61000-4-6
Fast Burst Transients – Test Level: 2 kV (direct contact) Level 3 conforms to IEC 61000-4-4
Immunity to Voltage Offset – Test Level: 30 % (500 ms) conforming to IEC 61000-4-11
Immunity to Voltage Offset – Test Level: 100 % (20 ms) conforming to IEC 61000-4-11
Electrical fast transient burst immunity test – test level: 1 kV (capacitive connection clip) level 3 conforming to IEC 61000-4-4
surge discharge immunity – test level: 1 kV (differential mode) level 3 conforming to IEC 61000-4-5
Surge Discharge Immunity – Test Level: 2 kV (Common Mode) Level 3 conforming to IEC 61000-4-5
Antistatic Interference – Test Level: 6 kV (Contact Discharge) Level 3 conforming to IEC 61000-4- 2
Anti-static interference – test level: 8 kV (air discharge) level 3 conforms to IEC 61000-4-2
RF electromagnetic field radiation immunity test – test level: 10 V/m (80 MHz…1 GHz) level 3 conforms IEC 61000-4-3
Conducted Immunity – Test Level: 10 V (0.15…80 MHz) Level 3 conforms to IEC 61000-4-6
Fast Burst Transients – Test Level: 2 kV (direct contact) Level 3 conforms to IEC 61000-4-4
Immunity to Voltage Offset – Test Level: 30 % (500 ms) conforming to IEC 61000-4-11
Immunity to Voltage Offset – Test Level: 100 % (20 ms) conforming to IEC 61000-4-11
Electrical fast transient burst immunity test – test level: 1 kV (capacitive connection clip) level 3 conforming to IEC 61000-4-4
surge discharge immunity – test level: 1 kV (differential mode) level 3 conforming to IEC 61000-4-5
Surge Discharge Immunity – Test Level: 2 kV (Common Mode) Level 3 conforming to IEC 61000-4-5
Antistatic Interference – Test Level: 6 kV (Contact Discharge) Level 3 conforming to IEC 61000-4- 2
Anti-static interference – test level: 8 kV (air discharge) level 3 conforms to IEC 61000-4-2
RF electromagnetic field radiation immunity test – test level: 10 V/m (80 MHz…1 GHz) level 3 conforms IEC 61000-4-3
Conducted Immunity – Test Level: 10 V (0.15…80 MHz) Level 3 conforms to IEC 61000-4-6
Fast Burst Transients – Test Level: 2 kV (direct contact) Level 3 conforms to IEC 61000-4-4
Immunity to Voltage Offset – Test Level: 30 % (500 ms) conforming to IEC 61000-4-11
Immunity to Voltage Offset – Test Level: 100 % (20 ms) conforming to IEC 61000-4-11
packaging unit
Unit Type of Package 1 PCE PCE PCE
Number of Units in Package 1 1 1 1
Package 1 Height 8.2 cm 2.6cm 8.2 cm
Package 1 Width 9.5cm 8.2 cm 9.5cm
Package 1 Length 2.6cm 9.5cm 2.6cm
Package 1 Weight 107.0g 114.0g 106.0g
Unit Type of Package 2 S02 S02 S02
Number of Units in Package 2 40 40 40
Package 2 Height 15.0cm 15.0cm 15.0cm
Package 2 Width 30.0cm 30.0cm 30.0cm
Package 2 Length 40.0cm 40.0cm 40.0cm
Package 2 Weight 4.735 kg 5.04 kg 4.695 kg
Unit Type of Package 3 PAL P06 PAL
Number of Units in Package 3 640 640 640
Package 3 Height 50.0cm 75.0cm 50.0cm
Package 3 Width 60.0cm 60.0cm 60.0cm
Package 3 Length 80.0cm 80.0cm 80.0cm
Package 3 Weight 86.18kg 72.96kg 92.58 kg
contract warranty
Warranty 18 months 18 months 18 months

 

Additional information

Weight N/A
Dimensions N/A

Related Products

IM12-04BPS-ZW1
Banner_Q20NFF50
Omron_General-purpose_Temperature_Controllers_E5CD-RX2DDM-802
IDS_10G POE+ PCie Card
PRA12-2DN
IDS_uEye_Cameras_1008775
$ 279.45 - $ 338.79
Select your currency