$ 59.11 – $ 82.34
Main | |||
Part Number | RE22R1ACMR | RE22R1AMR | RE22R1KMR |
Product Series | Harmony Timer Relays | Harmony Timer Relays | Harmony Timer Relays |
product type | Dual function relay | Dual function relay | Single function relay |
Solid state output type | Relay | Relay | Relay |
product short name | RE22 | RE22 | RE22 |
Rated output current | 8A | 8A | 5A |
Additional information | |||
Contact type and composition | 1 C/O timing contact, cadmium free | 1 C/O timing contact, cadmium free | 1 C/O timing contact, cadmium free |
delay type | On-delay and off-delay | Power on-delay | Delay on de-energization |
Delay range | 3…30 min 1…10 s 30…300 s 10…100 s 3…30 s 30…300 min 30…300 h 0.3…3 s 0.05. ..1 s 3…30 h |
3…30 s 30…300 s 10…100 s 0.05…1 s 1…10 s 30…300 h 30…300 min 0.3…3 s 3. ..30 h 3…30 min |
10…100 s 1…10 min 1…10 s 0.3…3 s 3…30 s 0.05…1 s 30…300 s |
control type | Knob Diagnostic Button Potentiometer External |
Knob diagnostic button |
Knob |
Rated supply voltage [Us] | 24…240 V AC/DC 50/60 Hz | 24…240 V AC/DC 50/60 Hz | 24…240 V AC/DC 50/60 Hz |
Release input voltage | <= 2.4V | <= 2.4V | <= 2.4V |
voltage range | 19…30V | 19…30V | 19…30V |
power supply frequency | 50…60 Hz +/- 5 % | 50…60 Hz +/- 5 % | 50…60 Hz +/- 5 % |
Wiring capacity | Screw terminal, 1 x 0.5…1 x 3.3 mm² (AWG 20…AWG 12) Solid without wire terminal Screw terminal, 2 x 0.5…2 x 2.5 mm² (AWG 20…AWG 14 ) solid without wire terminal screw terminal, 1 x 0.2…1 x 2.5 mm² (AWG 24…AWG 14) flexible wire with wire terminal screw terminal, 2 x 0.2…2 x 1.5 mm² ( AWG 24…AWG 16) flexible wire with wire terminal |
Screw terminal, 1 x 0.5…1 x 3.3 mm² (AWG 20…AWG 12) Solid without wire terminal Screw terminal, 2 x 0.5…2 x 2.5 mm² (AWG 20…AWG 14 ) solid without wire terminal screw terminal, 1 x 0.2…1 x 2.5 mm² (AWG 24…AWG 14) flexible wire with wire terminal screw terminal, 2 x 0.2…2 x 1.5 mm² ( AWG 24…AWG 16) flexible wire with wire terminal |
Screw terminal, 1 x 0.5…1 x 3.3 mm² (AWG 20…AWG 12) Solid without wire terminal Screw terminal, 2 x 0.5…2 x 2.5 mm² (AWG 20…AWG 14 ) solid without wire terminal screw terminal, 1 x 0.2…1 x 2.5 mm² (AWG 24…AWG 14) flexible wire with wire terminal screw terminal, 2 x 0.2…2 x 1.5 mm² ( AWG 24…AWG 16) flexible wire with wire terminal |
Tightening torque | 0.6…1 Nm conforming to IEC 60947-1 | 0.6…1 Nm conforming to IEC 60947-1 | 0.6…1 Nm conforming to IEC 60947-1 |
covering material | Flame retardant | Flame retardant | Flame retardant |
Repeatability | +/- 0.5 % according to IEC 61812-1 | +/- 0.5 % according to IEC 61812-1 | +/- 0.5 % according to IEC 61812-1 |
temperature deviation | +/- 0.05 %/°C | +/- 0.05 %/°C | +/- 0.05 %/°C |
voltage deviation | +/- 0.2 %/V | +/- 0.2 %/V | +/- 0.2 %/V |
Latency Accuracy Settings | +/- 10 % of full scale at 25 °C conforming to IEC 61812-1 | +/- 10 % of full scale at 25 °C conforming to IEC 61812-1 | +/- 10 % of full scale at 25 °C conforming to IEC 61812-1 |
Control signal pulse width | 100 ms with parallel load 30 ms |
100 ms with parallel load 30 ms |
|
Insulation resistance | 100 MΩ at 500 V DC conforming to IEC 60664-1 | 100 MΩ at 500 V DC conforming to IEC 60664-1 | 100 MΩ at 500 V DC conforming to IEC 60664-1 |
Recovery time | 120 ms discharge | 120 ms discharge | 100 ms discharge |
Anti-instantaneous power failure | 10ms | 10ms | 10ms |
Power consumption VA | 3 VA at 240 V AC | 3 VA at 240 V AC | 3 VA at 240 V AC |
power consumption[W] | 1.5 W at 240 V DC | 1.5 W at 240 V DC | 2 W at 240 V DC |
Switching capacity in VA | 2000VA | 2000VA | 1250VA |
Minimum switching current [Imin] | 10 mA at 5 V DC | 10 mA at 5 V DC | 10 mA at 5 V DC |
Maximum switching current | 8A | 8A | 5A |
Maximum Switching Voltage | 250 VAC | 250 VAC | 250 VAC |
Electrical life | 100000 cycles, 8 A at 250 V, AC-1 100000 cycles, 2 A at 24 V, DC-1 |
100000 cycles, 8 A at 250 V, AC-1 100000 cycles, 2 A at 24 V, DC-1 |
100000 cycles, 2 A at 24 V, DC-1 100000 cycles, 5 A at 250 V, AC-1 |
Mechanical life | 10000000 times | 10000000 times | 10000000 times |
Rated impulse withstand voltage | 5 kV for 1.2…50 µs conforming to IEC 60664-1 | 5 kV for 1.2…50 µs conforming to IEC 60664-1 | 5 kV for 1.2…50 µs conforming to IEC 60664-1 |
Power on delay | 100ms | 100ms | 200ms |
Creepage distance | 4 kV/3 conforming to IEC 60664-1 | 4 kV/3 conforming to IEC 60664-1 | 4 kV/3 conforming to IEC 60664-1 |
Type of overvoltage | III conforms to IEC 60664-1 | III conforms to IEC 60664-1 | III conforms to IEC 60664-1 |
Safe and reliable data | B10d = 190000 MTTFd = 205.4 years |
MTTFd = 308.2 years B10d = 280000 |
MTTFd = 194 years B10d = 180000 |
installation location | Any position | Any position | Any position |
installation method | 35 mm DIN rail conforming to EN/IEC 60715 | 35 mm DIN rail conforming to EN/IEC 60715 | 35 mm DIN rail conforming to EN/IEC 60715 |
LED status | Green LED backlight (constant) for dial indicator yellow LED (constant) for output closing yellow LED (quick flashing) for output opening timing yellow LED (slow flashing) for output closing timing |
Green LED backlight (constant) for dial indicator yellow LED (constant) for output closing yellow LED (quick flashing) for output opening timing yellow LED (slow flashing) for output closing timing |
Green LED Backlight (Constant) for Dial Indicator Yellow LED (Constant) for Output Closed Yellow LED (Constant) for Power On |
width | 22.5 mm | 22.5 mm | 22.5 mm |
Product Weight | 0.1 kg | 0.1 kg | 0.1 kg |
environment | |||
Insulation properties | 2.5 kV for 1 mA/1 minute at 50 Hz between relay output and supply and basic insulation to IEC 61812-1 | 2.5 kV for 1 mA/1 minute at 50 Hz between relay output and supply and basic insulation to IEC 61812-1 | 2.5 kV for 1 mA/1 minute at 50 Hz between relay output and supply and basic insulation to IEC 61812-1 |
Standards compliant | IEC 61812-1 UL 508 |
UL 508 IEC 61812-1 |
IEC 61812-1 UL 508 |
complies with directives | 2006/95/EC – Low Voltage Directive 2004/108/EC – Electromagnetic Compatibility |
2006/95/EC – Low Voltage Directive 2004/108/EC – Electromagnetic Compatibility |
2006/95/EC – Low Voltage Directive 2004/108/EC – Electromagnetic Compatibility |
certified product | CE CCC GL UL CSA EAC RCM |
CE UL GL CCC EAC RCM CSA |
CCC CSA GL RCM CE EAC UL |
operating temperature | -20…60°C | -20…60°C | -20…60°C |
storage environment temperature | -40…70°C | -40…70°C | -40…70°C |
IP protection class | IP40 housing: conforming to IEC 60529 IP50 front panel: conforming to IEC 60529 IP20 terminals: conforming to IEC 60529 |
IP40 housing: conforming to IEC 60529 IP50 front panel: conforming to IEC 60529 IP20 terminals: conforming to IEC 60529 |
IP40 housing: conforming to IEC 60529 IP50 front panel: conforming to IEC 60529 IP20 terminals: conforming to IEC 60529 |
pollution level | 3 Conforming to IEC 60664-1 | 3 Conforming to IEC 60664-1 | 3 Conforming to IEC 60664-1 |
Anti-vibration | 20 m/s² (f= 10…150 Hz) conforming to IEC 60068-2-6 | 20 m/s² (f= 10…150 Hz) conforming to IEC 60068-2-6 | 20 m/s² (f= 10…150 Hz) conforming to IEC 60068-2-6 |
impact resistance | 15 gn non-operating for 11 ms conforming to IEC 60068-2-27 5 gn operating for 11 ms conforming to IEC 60068-2-27 |
15 gn non-operating for 11 ms conforming to IEC 60068-2-27 5 gn operating for 11 ms conforming to IEC 60068-2-27 |
15 gn non-operating for 11 ms conforming to IEC 60068-2-27 5 gn operating for 11 ms conforming to IEC 60068-2-27 |
Relative humidity | 95 % at 25…55 °C | 95 % at 25…55 °C | 95 % at 25…55 °C |
electromagnetic compatibility | Electrical fast transient burst immunity test – test level: 1 kV (capacitive connection clip) level 3 conforming to IEC 61000-4-4 surge discharge immunity – test level: 1 kV (differential mode) level 3 conforming to IEC 61000-4-5 Surge Discharge Immunity – Test Level: 2 kV (Common Mode) Level 3 conforming to IEC 61000-4-5 Antistatic Interference – Test Level: 6 kV (Contact Discharge) Level 3 conforming to IEC 61000-4- 2 Anti-static interference – test level: 8 kV (air discharge) level 3 conforms to IEC 61000-4-2 RF electromagnetic field radiation immunity test – test level: 10 V/m (80 MHz…1 GHz) level 3 conforms IEC 61000-4-3 Conducted Immunity – Test Level: 10 V (0.15…80 MHz) Level 3 conforms to IEC 61000-4-6 Fast Burst Transients – Test Level: 2 kV (direct contact) Level 3 conforms to IEC 61000-4-4 Immunity to Voltage Offset – Test Level: 30 % (500 ms) conforming to IEC 61000-4-11 Immunity to Voltage Offset – Test Level: 100 % (20 ms) conforming to IEC 61000-4-11 |
Electrical fast transient burst immunity test – test level: 1 kV (capacitive connection clip) level 3 conforming to IEC 61000-4-4 surge discharge immunity – test level: 1 kV (differential mode) level 3 conforming to IEC 61000-4-5 Surge Discharge Immunity – Test Level: 2 kV (Common Mode) Level 3 conforming to IEC 61000-4-5 Antistatic Interference – Test Level: 6 kV (Contact Discharge) Level 3 conforming to IEC 61000-4- 2 Anti-static interference – test level: 8 kV (air discharge) level 3 conforms to IEC 61000-4-2 RF electromagnetic field radiation immunity test – test level: 10 V/m (80 MHz…1 GHz) level 3 conforms IEC 61000-4-3 Conducted Immunity – Test Level: 10 V (0.15…80 MHz) Level 3 conforms to IEC 61000-4-6 Fast Burst Transients – Test Level: 2 kV (direct contact) Level 3 conforms to IEC 61000-4-4 Immunity to Voltage Offset – Test Level: 30 % (500 ms) conforming to IEC 61000-4-11 Immunity to Voltage Offset – Test Level: 100 % (20 ms) conforming to IEC 61000-4-11 |
Electrical fast transient burst immunity test – test level: 1 kV (capacitive connection clip) level 3 conforming to IEC 61000-4-4 surge discharge immunity – test level: 1 kV (differential mode) level 3 conforming to IEC 61000-4-5 Surge Discharge Immunity – Test Level: 2 kV (Common Mode) Level 3 conforming to IEC 61000-4-5 Antistatic Interference – Test Level: 6 kV (Contact Discharge) Level 3 conforming to IEC 61000-4- 2 Anti-static interference – test level: 8 kV (air discharge) level 3 conforms to IEC 61000-4-2 RF electromagnetic field radiation immunity test – test level: 10 V/m (80 MHz…1 GHz) level 3 conforms IEC 61000-4-3 Conducted Immunity – Test Level: 10 V (0.15…80 MHz) Level 3 conforms to IEC 61000-4-6 Fast Burst Transients – Test Level: 2 kV (direct contact) Level 3 conforms to IEC 61000-4-4 Immunity to Voltage Offset – Test Level: 30 % (500 ms) conforming to IEC 61000-4-11 Immunity to Voltage Offset – Test Level: 100 % (20 ms) conforming to IEC 61000-4-11 |
packaging unit | |||
Unit Type of Package 1 | PCE | PCE | PCE |
Number of Units in Package 1 | 1 | 1 | 1 |
Package 1 Height | 2.6cm | 2.6cm | 2.6cm |
Package 1 Width | 8.2 cm | 8.2 cm | 8.2 cm |
Package 1 Length | 9.5cm | 9.5cm | 9.5cm |
Package 1 Weight | 100.0g | 92.0g | 93g |
Unit Type of Package 2 | S02 | S02 | |
Number of Units in Package 2 | 40 | 40 | |
Package 2 Height | 15.0cm | 15.0cm | |
Package 2 Width | 30.0cm | 30.0cm | |
Package 2 Length | 40.0cm | 40.0cm | |
Package 2 Weight | 4.405 kg | 4.261kg | |
Unit Type of Package 3 | P06 | P06 | |
Number of Units in Package 3 | 640 | 640 | |
Package 3 Height | 50.0cm | 75.0cm | |
Package 3 Width | 80.0cm | 60.0cm | |
Package 3 Length | 60.0cm | 80.0cm | |
Package 3 Weight | 79.78kg | 76.676kg | |
contract warranty | |||
Warranty | 18 months | 18 months | 18 months |
Main | |||
Part Number | RE22R1MLMR | RE22R2AMR | RE22R2QTMR |
Product Series | Harmony Timer Relays | Harmony Timer Relays | Harmony Timer Relays |
product type | Multifunction relay | Dual function relay | Single function relay |
Solid state output type | Relay | Relay | Relay |
product short name | RE22 | RE22 | RE22 |
Rated output current | 8A | 8A | 8A |
Additional information | |||
Contact type and composition | 1 C/O timing contact, cadmium free | 1 C/O timed contact, cadmium free 1 C/O timed or momentary contact, cadmium free |
2 OC timing contacts, cadmium free |
delay type | Asymmetrical flashing | Power on-delay | Star-delta |
Delay range | 0.05…1 s 30…300 min 30…300 h 30…300 s 3…30 h 0.3…3 s 3…30 min 3…30 s 10. ..100 s 1…10 s |
0.05…1 s 0.3…3 s 3…30 h 30…300 min 10…100 s 30…300 s 3…30 s 30…300 h 1. ..10 s 3…30 min |
1…10 s 3…30 s 10…100 s 30…300 min 0.05…1 s 3…30 min 0.3…3 s 30…300 s 3. ..30 h 30…300 h |
control type | Knob Diagnostic Button Potentiometer External |
Knob Diagnostic Button Potentiometer External |
Knob diagnostic button |
Rated supply voltage [Us] | 24…240 V AC/DC 50/60 Hz | 24…240 V AC/DC 50/60 Hz | 24…240 V AC/DC 50/60 Hz |
Release input voltage | <= 2.4V | <= 2.4V | <= 2.4V |
voltage range | 19…30V | 19…30V | 19…30V |
power supply frequency | 50…60 Hz +/- 5 % | 50…60 Hz +/- 5 % | 50…60 Hz +/- 5 % |
Wiring capacity | Screw terminal, 1 x 0.5…1 x 3.3 mm² (AWG 20…AWG 12) Solid without wire terminal Screw terminal, 2 x 0.5…2 x 2.5 mm² (AWG 20…AWG 14 ) solid without wire terminal screw terminal, 1 x 0.2…1 x 2.5 mm² (AWG 24…AWG 14) flexible wire with wire terminal screw terminal, 2 x 0.2…2 x 1.5 mm² ( AWG 24…AWG 16) flexible wire with wire terminal |
Screw terminal, 1 x 0.5…1 x 3.3 mm² (AWG 20…AWG 12) Solid without wire terminal Screw terminal, 2 x 0.5…2 x 2.5 mm² (AWG 20…AWG 14 ) solid without wire terminal screw terminal, 1 x 0.2…1 x 2.5 mm² (AWG 24…AWG 14) flexible wire with wire terminal screw terminal, 2 x 0.2…2 x 1.5 mm² ( AWG 24…AWG 16) flexible wire with wire terminal |
Screw terminal, 1 x 0.5…1 x 3.3 mm² (AWG 20…AWG 12) Solid without wire terminal Screw terminal, 2 x 0.5…2 x 2.5 mm² (AWG 20…AWG 14 ) solid without wire terminal screw terminal, 1 x 0.2…1 x 2.5 mm² (AWG 24…AWG 14) flexible wire with wire terminal screw terminal, 2 x 0.2…2 x 1.5 mm² ( AWG 24…AWG 16) flexible wire with wire terminal |
Tightening torque | 0.6…1 Nm conforming to IEC 60947-1 | 0.6…1 Nm conforming to IEC 60947-1 | 0.6…1 Nm conforming to IEC 60947-1 |
covering material | Flame retardant | Flame retardant | Flame retardant |
Repeatability | +/- 0.5 % according to IEC 61812-1 | +/- 0.5 % according to IEC 61812-1 | +/- 0.5 % according to IEC 61812-1 |
temperature deviation | +/- 0.05 %/°C | +/- 0.05 %/°C | +/- 0.05 %/°C |
voltage deviation | +/- 0.2 %/V | +/- 0.2 %/V | +/- 0.2 %/V |
Latency Accuracy Settings | +/- 10 % of full scale at 25 °C conforming to IEC 61812-1 | +/- 10 % of full scale at 25 °C conforming to IEC 61812-1 | +/- 10 % of full scale at 25 °C conforming to IEC 61812-1 |
Control signal pulse width | 100 ms with parallel load 30 ms |
100 ms with parallel load 30 ms |
|
Insulation resistance | 100 MΩ at 500 V DC conforming to IEC 60664-1 | 100 MΩ at 500 V DC conforming to IEC 60664-1 | 100 MΩ at 500 V DC conforming to IEC 60664-1 |
Recovery time | 120 ms discharge | 120 ms discharge | 120 ms discharge |
Anti-instantaneous power failure | 10ms | 10ms | 10ms |
Power consumption VA | 3 VA at 240 V AC | 3 VA at 240 V AC | 3 VA at 240 V AC |
power consumption[W] | 1.5 W at 240 V DC | 1.5 W at 240 V DC | 1.5 W at 240 V DC |
Switching capacity in VA | 2000VA | 2000VA | 2000VA |
Minimum switching current [Imin] | 10 mA at 5 V DC | 10 mA at 5 V DC | 10 mA at 5 V DC |
Maximum switching current | 8A | 8A | 8A |
Maximum Switching Voltage | 250 VAC | 250 VAC | 250 VAC |
Electrical life | 100000 cycles, 8 A at 250 V, AC-1 100000 cycles, 2 A at 24 V, DC-1 |
100000 cycles, 8 A at 250 V, AC-1 100000 cycles, 2 A at 24 V, DC-1 |
100000 cycles, 8 A at 250 V, AC-1 100000 cycles, 2 A at 24 V, DC-1 |
Mechanical life | 10000000 times | 10000000 times | 10000000 times |
Rated impulse withstand voltage | 5 kV for 1.2…50 µs conforming to IEC 60664-1 | 5 kV for 1.2…50 µs conforming to IEC 60664-1 | 5 kV for 1.2…50 µs conforming to IEC 60664-1 |
Power on delay | 100ms | 100ms | 100ms |
Creepage distance | 4 kV/3 conforming to IEC 60664-1 | 4 kV/3 conforming to IEC 60664-1 | 4 kV/3 conforming to IEC 60664-1 |
Type of overvoltage | III conforms to IEC 60664-1 | III conforms to IEC 60664-1 | III conforms to IEC 60664-1 |
Safe and reliable data | MTTFd = 194 years B10d = 180000 |
B10d = 200000 MTTFd = 216.8 years |
MTTFd = 342.4 years B10d = 320000 |
installation location | Any position | Any position | Any position |
installation method | 35 mm DIN rail conforming to EN/IEC 60715 | 35 mm DIN rail conforming to EN/IEC 60715 | 35 mm DIN rail conforming to EN/IEC 60715 |
LED status | Green LED backlight (constant) for dial indicator yellow LED (constant) for output closing yellow LED (quick flashing) for output opening timing yellow LED (slow flashing) for output closing timing |
Green LED backlight (constant) for dial indicator yellow LED (constant) for output closing yellow LED (quick flashing) for output opening timing yellow LED (slow flashing) for output closing timing |
Green LED backlight (constant) for dial indicator yellow LED (constant) for output closing yellow LED (quick flashing) for output opening timing yellow LED (slow flashing) for output closing timing |
width | 22.5 mm | 22.5 mm | 22.5 mm |
Product Weight | 0.1 kg | 0.105kg | 0.105kg |
environment | |||
Insulation properties | 2.5 kV for 1 mA/1 minute at 50 Hz between relay output and supply and basic insulation to IEC 61812-1 | 2.5 kV for 1 mA/1 minute at 50 Hz between relay output and supply and basic insulation to IEC 61812-1 | 2.5 kV for 1 mA/1 minute at 50 Hz between relay output and supply and basic insulation to IEC 61812-1 |
Standards compliant | IEC 61812-1 UL 508 |
UL 508 IEC 61812-1 |
IEC 61812-1 UL 508 |
complies with directives | 2004/108/EC – Electromagnetic Compatibility 2006/95/EC – Low Voltage Directive |
2004/108/EC – Electromagnetic Compatibility 2006/95/EC – Low Voltage Directive |
2006/95/EC – Low Voltage Directive 2004/108/EC – Electromagnetic Compatibility |
certified product | EAC UL GL CSA RCM CCC CE |
CE CCC GL UL RCM EAC CSA |
CCC GL UL EAC RCM CSA CE |
operating temperature | -20…60°C | -20…60°C | -20…60°C |
storage environment temperature | -40…70°C | -40…70°C | -40…70°C |
IP protection class | IP40 housing: conforming to IEC 60529 IP50 front panel: conforming to IEC 60529 IP20 terminals: conforming to IEC 60529 |
IP40 housing: conforming to IEC 60529 IP20 terminal: conforming to IEC 60529 IP50 cover: conforming to IEC 60529 |
IP40 housing: conforming to IEC 60529 IP20 terminal: conforming to IEC 60529 IP50 cover: conforming to IEC 60529 |
pollution level | 3 Conforming to IEC 60664-1 | 3 Conforming to IEC 60664-1 | 3 Conforming to IEC 60664-1 |
Anti-vibration | 20 m/s² (f= 10…150 Hz) conforming to IEC 60068-2-6 | 20 m/s² (f= 10…150 Hz) conforming to IEC 60068-2-6 | 20 m/s² (f= 10…150 Hz) conforming to IEC 60068-2-6 |
impact resistance | 15 gn non-operating for 11 ms conforming to IEC 60068-2-27 5 gn operating for 11 ms conforming to IEC 60068-2-27 |
15 gn non-operating for 11 ms conforming to IEC 60068-2-27 5 gn operating for 11 ms conforming to IEC 60068-2-27 |
15 gn non-operating for 11 ms conforming to IEC 60068-2-27 5 gn operating for 11 ms conforming to IEC 60068-2-27 |
Relative humidity | 95 % at 25…55 °C | 95 % at 25…55 °C | 95 % at 25…55 °C |
electromagnetic compatibility | Electrical fast transient burst immunity test – test level: 1 kV (capacitive connection clip) level 3 conforming to IEC 61000-4-4 surge discharge immunity – test level: 1 kV (differential mode) level 3 conforming to IEC 61000-4-5 Surge Discharge Immunity – Test Level: 2 kV (Common Mode) Level 3 conforming to IEC 61000-4-5 Antistatic Interference – Test Level: 6 kV (Contact Discharge) Level 3 conforming to IEC 61000-4- 2 Anti-static interference – test level: 8 kV (air discharge) level 3 conforms to IEC 61000-4-2 RF electromagnetic field radiation immunity test – test level: 10 V/m (80 MHz…1 GHz) level 3 conforms IEC 61000-4-3 Conducted Immunity – Test Level: 10 V (0.15…80 MHz) Level 3 conforms to IEC 61000-4-6 Fast Burst Transients – Test Level: 2 kV (direct contact) Level 3 conforms to IEC 61000-4-4 Immunity to Voltage Offset – Test Level: 30 % (500 ms) conforming to IEC 61000-4-11 Immunity to Voltage Offset – Test Level: 100 % (20 ms) conforming to IEC 61000-4-11 |
Electrical fast transient burst immunity test – test level: 1 kV (capacitive connection clip) level 3 conforming to IEC 61000-4-4 surge discharge immunity – test level: 1 kV (differential mode) level 3 conforming to IEC 61000-4-5 Surge Discharge Immunity – Test Level: 2 kV (Common Mode) Level 3 conforming to IEC 61000-4-5 Antistatic Interference – Test Level: 6 kV (Contact Discharge) Level 3 conforming to IEC 61000-4- 2 Anti-static interference – test level: 8 kV (air discharge) level 3 conforms to IEC 61000-4-2 RF electromagnetic field radiation immunity test – test level: 10 V/m (80 MHz…1 GHz) level 3 conforms IEC 61000-4-3 Conducted Immunity – Test Level: 10 V (0.15…80 MHz) Level 3 conforms to IEC 61000-4-6 Fast Burst Transients – Test Level: 2 kV (direct contact) Level 3 conforms to IEC 61000-4-4 Immunity to Voltage Offset – Test Level: 30 % (500 ms) conforming to IEC 61000-4-11 Immunity to Voltage Offset – Test Level: 100 % (20 ms) conforming to IEC 61000-4-11 |
Electrical fast transient burst immunity test – test level: 1 kV (capacitive connection clip) level 3 conforming to IEC 61000-4-4 surge discharge immunity – test level: 1 kV (differential mode) level 3 conforming to IEC 61000-4-5 Surge Discharge Immunity – Test Level: 2 kV (Common Mode) Level 3 conforming to IEC 61000-4-5 Antistatic Interference – Test Level: 6 kV (Contact Discharge) Level 3 conforming to IEC 61000-4- 2 Anti-static interference – test level: 8 kV (air discharge) level 3 conforms to IEC 61000-4-2 RF electromagnetic field radiation immunity test – test level: 10 V/m (80 MHz…1 GHz) level 3 conforms IEC 61000-4-3 Conducted Immunity – Test Level: 10 V (0.15…80 MHz) Level 3 conforms to IEC 61000-4-6 Fast Burst Transients – Test Level: 2 kV (direct contact) Level 3 conforms to IEC 61000-4-4 Immunity to Voltage Offset – Test Level: 30 % (500 ms) conforming to IEC 61000-4-11 Immunity to Voltage Offset – Test Level: 100 % (20 ms) conforming to IEC 61000-4-11 |
packaging unit | |||
Unit Type of Package 1 | PCE | PCE | PCE |
Number of Units in Package 1 | 1 | 1 | 1 |
Package 1 Height | 8.2 cm | 2.6cm | 8.2 cm |
Package 1 Width | 9.5cm | 8.2 cm | 9.5cm |
Package 1 Length | 2.6cm | 9.5cm | 2.6cm |
Package 1 Weight | 107.0g | 114.0g | 106.0g |
Unit Type of Package 2 | S02 | S02 | S02 |
Number of Units in Package 2 | 40 | 40 | 40 |
Package 2 Height | 15.0cm | 15.0cm | 15.0cm |
Package 2 Width | 30.0cm | 30.0cm | 30.0cm |
Package 2 Length | 40.0cm | 40.0cm | 40.0cm |
Package 2 Weight | 4.735 kg | 5.04 kg | 4.695 kg |
Unit Type of Package 3 | PAL | P06 | PAL |
Number of Units in Package 3 | 640 | 640 | 640 |
Package 3 Height | 50.0cm | 75.0cm | 50.0cm |
Package 3 Width | 60.0cm | 60.0cm | 60.0cm |
Package 3 Length | 80.0cm | 80.0cm | 80.0cm |
Package 3 Weight | 86.18kg | 72.96kg | 92.58 kg |
contract warranty | |||
Warranty | 18 months | 18 months | 18 months |
Weight | N/A |
---|---|
Dimensions | N/A |
INOSAKI Limited
RM B 5/F Gaylord Comm,
Bldg 114-118 Lockhart Rd.
Hong Kong
INOSAKI Sdn. Bhd.
2-1-9, Ground Floor, One Square, Tingkat Mahsuri 1,
11900 Bayan Lepas, Penan
INOSAKI Pte. Ltd.
101 Upper Cross Street,
No. 06-17, People’s Park Centre,