Contact Us:
sales@inosaki.com

EasyPact D3N – LC1E – 3 Poles (3NO) Contactor, 160A – Schneider Contactors & Reversing Contactors

$ 109.48$ 110.86

Specifications

Main
Part Number LC1E160M5N LC1E160Q5N
Product Series Compact Compact
product type Contactor Contactor
product short name LC1E LC1E
Application field of contactor Applied to non-inductive or micro-inductive loads, and
resistance furnaces to AC loads with a power factor greater than or equal to 0.95
Applied to AC loads with power factor greater than or equal to 0.95
Applied to non-inductive or slightly inductive loads, resistance furnaces
use category AC-3AC
-1
AC-3AC
-1
number of poles 3P 3P
Rated working voltage [Ue] Power circuit: <= 690 V AC 50/60 Hz Power circuit: <= 690 V AC 50/60 Hz
Rated operating current [Ie] 160 A 55 °C) at <= 440 V AC AC-3 for power circuits
200 A 55 °C) at <= 440 V AC AC-1 for power circuits
160 A 55 °C) at <= 440 V AC AC-3 for power circuits
200 A 55 °C) at <= 440 V AC AC-1 for power circuits
[Uc] control circuit voltage 230V AC 50Hz 380V AC 50Hz
Additional information
Motor power (kW) 45 kW at 220/230 V AC 50/60 Hz (AC-3)
75 kW at 380/400 V AC 50/60 Hz (AC-3)
80 kW at 415/440 V AC 50/ 60 Hz (AC-3)
90 kW at 500 V AC 50/60 Hz (AC-3)
100 kW at 660/690 V AC 50/60 Hz (AC-3)
45 kW at 220/230 V AC 50/60 Hz (AC-3)
75 kW at 380/400 V AC 50/60 Hz (AC-3)
80 kW at 415/440 V AC 50/ 60 Hz (AC-3)
90 kW at 500 V AC 50/60 Hz (AC-3)
100 kW at 660/690 V AC 50/60 Hz (AC-3)
Loop contact type 3 NO 3 NO
Conventional thermal current [Ith] 200 A at <40 °C for power circuits 200 A at <40 °C for power circuits
Rated making capacity [Irms] 140 A AC for auxiliary contacts according to IEC 60947-5-1
1600 A at 440 V AC for power circuits according to IEC 60947-4-1
140 A AC for auxiliary contacts according to IEC 60947-5-1
1600 A at 440 V AC for power circuits according to IEC 60947-4-1
Rated breaking capacity 1280 A at 440 V for power circuits conforming to IEC 60947 1280 A at 440 V for power circuits conforming to IEC 60947
Rated short-time withstand current [Icw] 1400 A at <40 °C – 10 s for power circuits 1400 A at <40 °C – 10 s for power circuits
Fuses for use with relays 10 A gG at <= 690 V for type 1 suitable control circuits conforming to IEC 60947-5-1
315 A gG at <= 690 V for type 1 suitable power circuits
10 A gG at <= 690 V for type 1 suitable control circuits conforming to IEC 60947-5-1
315 A gG at <= 690 V for type 1 suitable power circuits
average impedance 0.6 mΩ – Ith 200 A 50 Hz for power circuits 0.6 mΩ – Ith 200 A 50 Hz for power circuits
power consumption per pole 24W AC-1
15W AC-3
24W AC-1
15W AC-3
Rated insulation voltage [Ui] 690 V conforming to IEC 60947-4-1 690 V conforming to IEC 60947-4-1
Overvoltage category III III
pollution level 3 3
Rated impulse withstand voltage [Uimp] 8 kV coil not connected to power circuit conforming to IEC 60947 8 kV coil not connected to power circuit conforming to IEC 60947
Mechanical life 400000 times 400000 times
Electrical life 800,000 AC-3
250,000 AC-1
800,000 AC-3
250,000 AC-1
Control loop characteristics AC at 50 Hz standard AC at 50 Hz standard
Control voltage limit 0.85…1.1 Uc 55 °C run 50 Hz
0.35…0.55 Uc 55 °C release 50 Hz
0.85…1.1 Uc 55 °C run 50 Hz
0.35…0.55 Uc 55 °C release 50 Hz
(~50Hz pickup) power consumption (VA) 300VA 50Hz (0.920°C) 300VA 50Hz (0.920°C)
(~50Hz hold) power consumption (VA) 22VA 50Hz (0.920°C) 22VA 50Hz (0.920°C)
heat dissipation 3…8 W for control circuits 3…8 W for control circuits
action time 20…50 ms off
6…20 ms on opening
20…50 ms off
6…20 ms on opening
operating frequency 1200 cycles/h at <55 °C 1200 cycles/h at <55 °C
Wiring capacity Control circuit: screw-on2 1…2.5 mm² Cable option: flexible cord with cable terminals
Power circuit: screw-on1 10…120 mm² Cable option: flexible cable with cable terminal
Power circuit: screw-on2 20 …170 mm² Cable option: flexible with wire terminals Power
circuit: screw tight1 10…120 mm² Cable option: solid without wire terminals Power
circuit: screw tight2 20…170 mm² Cable option: Rigid wire without wire terminal
Control circuit: Bolt fastening1 1…2.5 mm² Cable selection: Flexible wire without wire terminal
Control circuit: Bolt fastening2 1…2.5 mm² Cable selection: Flexible wire without wire Terminals
Control circuit: Bolt fastening1 1…2.5 mm² Cable selection: Flexible wire with wire terminal
Control circuit: Bolt fastening1 1…2.5 mm² Cable selection: Hard wire without wire terminal
Control circuit: Bolt fastening 2 1…2.5 mm² Cable option: solid without cable terminals
Control circuit: screw-on2 1…2.5 mm² Cable option: flexible cord with cable terminals
Power circuit: screw-on1 10…120 mm² Cable option: flexible cable with cable terminal
Power circuit: screw-on2 20 …170 mm² Cable option: flexible with wire terminals Power
circuit: screw tight1 10…120 mm² Cable option: solid without wire terminals Power
circuit: screw tight2 20…170 mm² Cable option: Rigid wire without wire terminal
Control circuit: Bolt fastening1 1…2.5 mm² Cable selection: Flexible wire without wire terminal
Control circuit: Bolt fastening2 1…2.5 mm² Cable selection: Flexible wire without wire Terminals
Control circuit: Bolt fastening1 1…2.5 mm² Cable selection: Flexible wire with wire terminal
Control circuit: Bolt fastening1 1…2.5 mm² Cable selection: Hard wire without wire terminal
Control circuit: Bolt fastening 2 1…2.5 mm² Cable option: solid without cable terminals
Tightening torque Control circuit: 1.2 Nm
Power circuit: 12 Nm
Control circuit: 1.2 Nm
Power circuit: 12 Nm
Auxiliary contact type 1 NO + 1 NC 1 NO + 1 NC
Minimum switching voltage 17 V for control circuits 17 V for control circuits
Minimum switching current [Imin] 5 mA for control loop 5 mA for control loop
Insulation resistance > 10 MΩ for control loops > 10 MΩ for control loops
non-overlapping time 1.5 ms power-on to ensure NC and NO contact
1.5 ms power-off to ensure NC and NO contact
1.5 ms power-on to ensure NC and NO contact
1.5 ms power-off to ensure NC and NO contact
installation method DIN rail mount
chassis mount
DIN rail mount
chassis mount
environment
standard IEC 60947-4-1
GB 14048.4
IEC 60947-4-1
GB 14048.4
certified product CCC CCC
IP protection class IP20 conforming to IEC 60529 IP20 conforming to IEC 60529
Protective measures TH (pollution degree 3) conforming to IEC 60068 TH (pollution degree 3) conforming to IEC 60068
ambient air temperature -20…70 °C (allowed at Uc)
5…55 °C operation
-60…80 °C storage
-20…70 °C (allowed at Uc)
5…55 °C operation
-60…80 °C storage
working altitude 3000 m None 3000 m None
Fire resistance and abnormal high temperature resistance 850 °C conforming to IEC 60695-2-1 850 °C conforming to IEC 60695-2-1
Shock and vibration resistance Shock resistance with contacts open (1.5 gn (5…300 Hz))
shock resistance with contacts closed (3 gn (5…300 Hz))
shock resistance with contacts open (6 gn (11ms))
shock resistance Performance Contact closed state (7 gn (11ms))
Shock resistance with contacts open (1.5 gn (5…300 Hz))
shock resistance with contacts closed (3 gn (5…300 Hz))
shock resistance with contacts open (6 gn (11ms))
shock resistance Performance Contact closed state (7 gn (11ms))
high 158 mm 158 mm
width 120 mm 120 mm
depth 132 mm 132 mm
Product Weight 2.3 kg 2.3 kg
packaging unit
Unit Type of Package 1 PCE PCE
Number of Units in Package 1 1 1
Package 1 Height 17.5cm 17.5cm
Package 1 Width 16.5cm 16.5cm
Package 1 Length 20.5cm 20.5cm
Package 1 Weight 2.397kg 2.381kg
Unit Type of Package 2 P06 P06
Number of Units in Package 2 Twenty four Twenty four
Package 2 Height 73.0cm 73.0cm
Package 2 Width 60.0cm 60.0cm
Package 2 Length 80.0cm 80.0cm
Package 2 Weight 71.494 kg 71.11kg
contract warranty
Warranty 18 months 18 months

 

Additional information

Weight N/A
Dimensions N/A

Related Products

Pheonix-Contact_Relay Module-EMG 17-REL-KSR-W230-21-21-LC
IDS Gige cable ueye camera ids imaging
Pheonix-Contact_Power Supply_QUINT4-PS-1AC-110DC-4
SIEMENS_SIMATIC_ET_200SP__CPU 1512SP-1 PN
1605941172(1)
Festo_Pressure sensors and vacuum sensor_SPAN-B2R-G18F-PN-PN-L1_8003300_1
Select your currency