$ 661.98 – $ 7,593.96
Main | ||||
Part Number |
ATS48D17Q |
ATS48D32Q |
ATS48D47Q |
ATS48D62Q |
Range of product | Altistart 48 | Altistart 48 | Altistart 48 | Altistart 48 |
Product or component type | Soft starter | Soft starter | Soft starter | Soft starter |
Product destination | Asynchronous motors | Asynchronous motors | Asynchronous motors | Asynchronous motors |
Product specific application | Heavy duty industry and pumps | Heavy duty industry and pumps | Heavy duty industry and pumps | Heavy duty industry and pumps |
Device short name | ATS48 | ATS48 | ATS48 | ATS48 |
Utilisation category | AC-53A | AC-53A | AC-53A | AC-53A |
Ue power supply voltage | 230…415 V – 15…10 % | 230…415 V – 15…10 % | 230…415 V – 15…10 % | 230…415 V – 15…10 % |
power supply frequency | 50…60 Hz – 5…5 % | 50…60 Hz – 5…5 % | 50…60 Hz – 5…5 % | 50…60 Hz – 5…5 % |
motor power kW | 7.5 kW at 230 V connection to the motor delta terminals for standard applications 7.5 kW at 400 V connection in the motor supply line for standard applications 11 kW at 400 V connection to the motor delta terminals for severe applications 15 kW at 400 V connection to the motor delta terminals for standard applications 3 kW at 230 V connection in the motor supply line for severe applications 4 kW at 230 V connection in the motor supply line for standard applications 5.5 kW at 230 V connection to the motor delta terminals for severe applications 5.5 kW at 400 V connection in the motor supply line for severe applications |
7.5 kW at 230 V connection in the motor supply line for standard applications 9 kW at 230 V connection to the motor delta terminals for severe applications 11 kW at 400 V connection in the motor supply line for severe applications 15 kW at 230 V connection to the motor delta terminals for standard applications 15 kW at 400 V connection in the motor supply line for standard applications 18.5 kW at 400 V connection to the motor delta terminals for severe applications 22 kW at 400 V connection to the motor delta terminals for standard applications 5.5 kW at 230 V connection in the motor supply line for severe applications |
9 kW at 230 V connection in the motor supply line for severe applications 11 kW at 230 V connection in the motor supply line for standard applications 18.5 kW at 230 V connection to the motor delta terminals for severe applications 18.5 kW at 400 V connection in the motor supply line for severe applications 22 kW at 230 V connection to the motor delta terminals for standard applications 22 kW at 400 V connection in the motor supply line for standard applications 30 kW at 400 V connection to the motor delta terminals for severe applications 45 kW at 400 V connection to the motor delta terminals for standard applications |
55 kW at 400 V connection to the motor delta terminals for standard applications 11 kW at 230 V connection in the motor supply line for severe applications 15 kW at 230 V connection in the motor supply line for standard applications 22 kW at 230 V connection to the motor delta terminals for severe applications 22 kW at 400 V connection in the motor supply line for severe applications 30 kW at 230 V connection to the motor delta terminals for standard applications 30 kW at 400 V connection in the motor supply line for standard applications 45 kW at 400 V connection to the motor delta terminals for severe applications |
Complementary | ||||
Device connection | To the motor delta terminals In the motor supply line |
In the motor supply line To the motor delta terminals |
To the motor delta terminals In the motor supply line |
To the motor delta terminals In the motor supply line |
protection type | Phase failure: line Thermal protection: motor Thermal protection: starter |
Phase failure: line Thermal protection: motor Thermal protection: starter |
Phase failure: line Thermal protection: motor Thermal protection: starter |
Phase failure: line Thermal protection: motor Thermal protection: starter |
Standards | EN/IEC 60947-4-2 | EN/IEC 60947-4-2 | EN/IEC 60947-4-2 | EN/IEC 60947-4-2 |
Product certifications | UL CCC GOST DNV CSA NOM 117 SEPRO TCF C-Tick |
NOM 117 CSA SEPRO CCC C-Tick UL TCF DNV GOST |
UL TCF NOM 117 GOST CCC CSA DNV C-Tick SEPRO |
TCF CSA DNV UL C-Tick NOM 117 CCC SEPRO GOST |
Marking | CE | CE | CE | CE |
Discrete input number | 5 | 5 | 5 | 5 |
discrete input type | PTC, 750 Ohm at 25 °C (Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm |
PTC, 750 Ohm at 25 °C (Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm |
PTC, 750 Ohm at 25 °C (Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm |
PTC, 750 Ohm at 25 °C (Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm |
discrete input logic | Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA | Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA | Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA | Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA |
minimum switching current | 10 mA at 6 V DC for relay outputs | 10 mA at 6 V DC for relay outputs | 10 mA at 6 V DC for relay outputs | 10 mA at 6 V DC for relay outputs |
Discrete output number | 2 | 2 | 2 | 2 |
discrete output type | (LO1) logic output 0 V common configurable (LO2) logic output 0 V common configurable (R1) relay outputs fault relay NO (R2) relay outputs end of starting relay NO (R3) relay outputs motor powered NO |
(LO1) logic output 0 V common configurable (LO2) logic output 0 V common configurable (R1) relay outputs fault relay NO (R2) relay outputs end of starting relay NO (R3) relay outputs motor powered NO |
(LO1) logic output 0 V common configurable (LO2) logic output 0 V common configurable (R1) relay outputs fault relay NO (R2) relay outputs end of starting relay NO (R3) relay outputs motor powered NO |
(LO1) logic output 0 V common configurable (LO2) logic output 0 V common configurable (R1) relay outputs fault relay NO (R2) relay outputs end of starting relay NO (R3) relay outputs motor powered NO |
analogue output type | Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm | Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm | Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm | Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm |
Communication port protocol | Modbus | Modbus | Modbus | Modbus |
connector type | 1 RJ45 | 1 RJ45 | 1 RJ45 | 1 RJ45 |
Communication data link | Serial | Serial | Serial | Serial |
Physical interface | RS485 multidrop | RS485 multidrop | RS485 multidrop | RS485 multidrop |
Transmission rate | 4800, 9600 or 19200 bps | 4800, 9600 or 19200 bps | 4800, 9600 or 19200 bps | 4800, 9600 or 19200 bps |
Function available | External bypass (optional) | External bypass (optional) | External bypass (optional) | External bypass (optional) |
Operating position | Vertical +/- 10 degree | Vertical +/- 10 degree | Vertical +/- 10 degree | Vertical +/- 10 degree |
Height | 275 mm | 275 mm | 275 mm | 290 mm |
Width | 160 mm | 160 mm | 160 mm | 190 mm |
Depth | 190 mm | 190 mm | 190 mm | 235 mm |
Net weight | 4.9 kg | 4.9 kg | 4.9 kg | 8.3 kg |
Environment | ||||
electromagnetic compatibility | Conducted and radiated emissions level A conforming to IEC 60947-4-2 Conducted and radiated emissions level B conforming to IEC 60947-4-2 Damped oscillating waves level 3 conforming to IEC 61000-4-12 Electrostatic discharge level 3 conforming to IEC 61000-4-2 Immunity to electrical transients level 4 conforming to IEC 61000-4-4 Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3 Voltage/current impulse level 3 conforming to IEC 61000-4-5 |
Conducted and radiated emissions level A conforming to IEC 60947-4-2 Conducted and radiated emissions level B conforming to IEC 60947-4-2 Damped oscillating waves level 3 conforming to IEC 61000-4-12 Electrostatic discharge level 3 conforming to IEC 61000-4-2 Immunity to electrical transients level 4 conforming to IEC 61000-4-4 Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3 Voltage/current impulse level 3 conforming to IEC 61000-4-5 |
Conducted and radiated emissions level A conforming to IEC 60947-4-2 Conducted and radiated emissions level B conforming to IEC 60947-4-2 Damped oscillating waves level 3 conforming to IEC 61000-4-12 Electrostatic discharge level 3 conforming to IEC 61000-4-2 Immunity to electrical transients level 4 conforming to IEC 61000-4-4 Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3 Voltage/current impulse level 3 conforming to IEC 61000-4-5 |
Conducted and radiated emissions level A conforming to IEC 60947-4-2 Conducted and radiated emissions level B conforming to IEC 60947-4-2 Damped oscillating waves level 3 conforming to IEC 61000-4-12 Electrostatic discharge level 3 conforming to IEC 61000-4-2 Immunity to electrical transients level 4 conforming to IEC 61000-4-4 Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3 Voltage/current impulse level 3 conforming to IEC 61000-4-5 |
relative humidity | 0…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3 | 0…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3 | 0…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3 | 0…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3 |
ambient air temperature for operation | 40…60 °C (with current derating of 2 % per °C) -10…40 °C (without derating) |
40…60 °C (with current derating of 2 % per °C) -10…40 °C (without derating) |
40…60 °C (with current derating of 2 % per °C) -10…40 °C (without derating) |
40…60 °C (with current derating of 2 % per °C) -10…40 °C (without derating) |
Ambient air temperature for storage | -25…70 °C | -25…70 °C | -25…70 °C | -25…70 °C |
operating altitude | <= 1000 m without derating > 1000…2000 m with current derating of 2.2 % per additional 100 m |
<= 1000 m without derating > 1000…2000 m with current derating of 2.2 % per additional 100 m |
<= 1000 m without derating > 1000…2000 m with current derating of 2.2 % per additional 100 m |
<= 1000 m without derating > 1000…2000 m with current derating of 2.2 % per additional 100 m |
Packing Units | ||||
Unit Type of Package 1 | PCE | PCE | PCE | PCE |
Number of Units in Package 1 | 1 | 1 | 1 | 1 |
Package 1 Height | 27.0 cm | 28.5 cm | 28.5 cm | 35.4 cm |
Package 1 Width | 25.0 cm | 26 cm | 26.0 cm | 36.2 cm |
Package 1 Length | 35.0 cm | 37 cm | 37.0 cm | 44.8 cm |
Package 1 Weight | 5.682 kg | 5.819 kg | 5.83 kg | 9.246 kg |
Unit Type of Package 2 | P06 | P06 | P06 | P06 |
Number of Units in Package 2 | 8 | 8 | 8 | 2 |
Package 2 Height | 73.5 cm | 73.5 cm | 73.5 cm | 73.5 cm |
Package 2 Width | 80.0 cm | 80 cm | 80.0 cm | 80.0 cm |
Package 2 Length | 60.0 cm | 60 cm | 60.0 cm | 60.0 cm |
Package 2 Weight | 58.456 kg | 58.768 kg | 58.936 kg | 31.792 kg |
Contractual warranty | ||||
Warranty | 18 months | 18 months | 18 months | 18 months |
Main | ||||
Part Number |
ATS48D75Q |
ATS48D88Q |
ATS48C11Q |
ATS48C14Q |
Range of product | Altistart 48 | Altistart 48 | Altistart 48 | Altistart 48 |
Product or component type | Soft starter | Soft starter | Soft starter | Soft starter |
Product destination | Asynchronous motors | Asynchronous motors | Asynchronous motors | Asynchronous motors |
Product specific application | Heavy duty industry and pumps | Heavy duty industry and pumps | Heavy duty industry and pumps | Heavy duty industry and pumps |
Device short name | ATS48 | ATS48 | ATS48 | ATS48 |
Utilisation category | AC-53A | AC-53A | AC-53A | AC-53A |
Ue power supply voltage | 230…415 V – 15…10 % | 230…415 V – 15…10 % | 230…415 V – 15…10 % | 230…415 V – 15…10 % |
power supply frequency | 50…60 Hz – 5…5 % | 50…60 Hz – 5…5 % | 50…60 Hz – 5…5 % | 50…60 Hz – 5…5 % |
motor power kW | 55 kW at 400 V connection to the motor delta terminals for standard applications 55 kW at 400 V connection to the motor delta terminals for severe applications 15 kW at 230 V connection in the motor supply line for severe applications 18.5 kW at 230 V connection in the motor supply line for standard applications 30 kW at 230 V connection to the motor delta terminals for severe applications 30 kW at 400 V connection in the motor supply line for severe applications 37 kW at 230 V connection to the motor delta terminals for standard applications 37 kW at 400 V connection in the motor supply line for standard applications |
55 kW at 400 V connection to the motor delta terminals for severe applications 75 kW at 400 V connection to the motor delta terminals for standard applications 18.5 kW at 230 V connection in the motor supply line for severe applications 22 kW at 230 V connection in the motor supply line for standard applications 37 kW at 230 V connection to the motor delta terminals for severe applications 37 kW at 400 V connection in the motor supply line for severe applications 45 kW at 230 V connection to the motor delta terminals for standard applications 45 kW at 400 V connection in the motor supply line for standard applications |
55 kW at 230 V connection to the motor delta terminals for standard applications 55 kW at 400 V connection in the motor supply line for standard applications 75 kW at 400 V connection to the motor delta terminals for severe applications 90 kW at 400 V connection to the motor delta terminals for standard applications 22 kW at 230 V connection in the motor supply line for severe applications 30 kW at 230 V connection in the motor supply line for standard applications 45 kW at 230 V connection to the motor delta terminals for severe applications 45 kW at 400 V connection in the motor supply line for severe applications |
55 kW at 230 V connection to the motor delta terminals for severe applications 55 kW at 400 V connection in the motor supply line for severe applications 75 kW at 230 V connection to the motor delta terminals for standard applications 75 kW at 400 V connection in the motor supply line for standard applications 90 kW at 400 V connection to the motor delta terminals for severe applications 110 kW at 400 V connection to the motor delta terminals for standard applications 30 kW at 230 V connection in the motor supply line for severe applications 37 kW at 230 V connection in the motor supply line for standard applications |
Complementary | ||||
Device connection | To the motor delta terminals In the motor supply line |
To the motor delta terminals In the motor supply line |
To the motor delta terminals In the motor supply line |
To the motor delta terminals In the motor supply line |
protection type | Phase failure: line Thermal protection: motor Thermal protection: starter |
Phase failure: line Thermal protection: motor Thermal protection: starter |
Phase failure: line Thermal protection: motor Thermal protection: starter |
Phase failure: line Thermal protection: motor Thermal protection: starter |
Standards | EN/IEC 60947-4-2 | EN/IEC 60947-4-2 | EN/IEC 60947-4-2 | EN/IEC 60947-4-2 |
Product certifications | DNV GOST UL NOM 117 CCC CSA C-Tick TCF SEPRO |
CCC CSA SEPRO UL C-Tick GOST NOM 117 TCF DNV |
C-Tick GOST SEPRO NOM 117 CSA TCF DNV CCC UL |
CSA UL DNV GOST NOM 117 C-Tick SEPRO CCC TCF |
Marking | CE | CE | CE | CE |
Discrete input number | 5 | 5 | 5 | 5 |
discrete input type | PTC, 750 Ohm at 25 °C (Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm |
PTC, 750 Ohm at 25 °C (Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm |
PTC, 750 Ohm at 25 °C (Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm |
PTC, 750 Ohm at 25 °C (Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm |
discrete input logic | Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA | Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA | Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA | Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA |
minimum switching current | 10 mA at 6 V DC for relay outputs | 10 mA at 6 V DC for relay outputs | 10 mA at 6 V DC for relay outputs | 10 mA at 6 V DC for relay outputs |
Discrete output number | 2 | 2 | 2 | 2 |
discrete output type | (LO1) logic output 0 V common configurable (LO2) logic output 0 V common configurable (R1) relay outputs fault relay NO (R2) relay outputs end of starting relay NO (R3) relay outputs motor powered NO |
(LO1) logic output 0 V common configurable (LO2) logic output 0 V common configurable (R1) relay outputs fault relay NO (R2) relay outputs end of starting relay NO (R3) relay outputs motor powered NO |
(LO1) logic output 0 V common configurable (LO2) logic output 0 V common configurable (R1) relay outputs fault relay NO (R2) relay outputs end of starting relay NO (R3) relay outputs motor powered NO |
(LO1) logic output 0 V common configurable (LO2) logic output 0 V common configurable (R1) relay outputs fault relay NO (R2) relay outputs end of starting relay NO (R3) relay outputs motor powered NO |
analogue output type | Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm | Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm | Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm | Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm |
Communication port protocol | Modbus | Modbus | Modbus | Modbus |
connector type | 1 RJ45 | 1 RJ45 | 1 RJ45 | 1 RJ45 |
Communication data link | Serial | Serial | Serial | Serial |
Physical interface | RS485 multidrop | RS485 multidrop | RS485 multidrop | RS485 multidrop |
Transmission rate | 4800, 9600 or 19200 bps | 4800, 9600 or 19200 bps | 4800, 9600 or 19200 bps | 4800, 9600 or 19200 bps |
Function available | External bypass (optional) | External bypass (optional) | External bypass (optional) | External bypass (optional) |
Operating position | Vertical +/- 10 degree | Vertical +/- 10 degree | Vertical +/- 10 degree | Vertical +/- 10 degree |
Height | 290 mm | 290 mm | 290 mm | 340 mm |
Width | 190 mm | 190 mm | 190 mm | 200 mm |
Depth | 235 mm | 235 mm | 235 mm | 265 mm |
Net weight | 8.3 kg | 8.3 kg | 8.3 kg | 12.4 kg |
Environment | ||||
electromagnetic compatibility | Conducted and radiated emissions level A conforming to IEC 60947-4-2 Conducted and radiated emissions level B conforming to IEC 60947-4-2 Damped oscillating waves level 3 conforming to IEC 61000-4-12 Electrostatic discharge level 3 conforming to IEC 61000-4-2 Immunity to electrical transients level 4 conforming to IEC 61000-4-4 Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3 Voltage/current impulse level 3 conforming to IEC 61000-4-5 |
Conducted and radiated emissions level A conforming to IEC 60947-4-2 Conducted and radiated emissions level B conforming to IEC 60947-4-2 Damped oscillating waves level 3 conforming to IEC 61000-4-12 Electrostatic discharge level 3 conforming to IEC 61000-4-2 Immunity to electrical transients level 4 conforming to IEC 61000-4-4 Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3 Voltage/current impulse level 3 conforming to IEC 61000-4-5 |
Conducted and radiated emissions level A conforming to IEC 60947-4-2 Conducted and radiated emissions level B conforming to IEC 60947-4-2 Damped oscillating waves level 3 conforming to IEC 61000-4-12 Electrostatic discharge level 3 conforming to IEC 61000-4-2 Immunity to electrical transients level 4 conforming to IEC 61000-4-4 Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3 Voltage/current impulse level 3 conforming to IEC 61000-4-5 |
Conducted and radiated emissions level A conforming to IEC 60947-4-2 Conducted and radiated emissions level B conforming to IEC 60947-4-2 Damped oscillating waves level 3 conforming to IEC 61000-4-12 Electrostatic discharge level 3 conforming to IEC 61000-4-2 Immunity to electrical transients level 4 conforming to IEC 61000-4-4 Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3 Voltage/current impulse level 3 conforming to IEC 61000-4-5 |
relative humidity | 0…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3 | 0…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3 | 0…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3 | 0…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3 |
ambient air temperature for operation | 40…60 °C (with current derating of 2 % per °C) -10…40 °C (without derating) |
40…60 °C (with current derating of 2 % per °C) -10…40 °C (without derating) |
40…60 °C (with current derating of 2 % per °C) -10…40 °C (without derating) |
40…60 °C (with current derating of 2 % per °C) -10…40 °C (without derating) |
Ambient air temperature for storage | -25…70 °C | -25…70 °C | -25…70 °C | -25…70 °C |
operating altitude | <= 1000 m without derating > 1000…2000 m with current derating of 2.2 % per additional 100 m |
<= 1000 m without derating > 1000…2000 m with current derating of 2.2 % per additional 100 m |
<= 1000 m without derating > 1000…2000 m with current derating of 2.2 % per additional 100 m |
<= 1000 m without derating > 1000…2000 m with current derating of 2.2 % per additional 100 m |
Packing Units | ||||
Unit Type of Package 1 | PCE | PCE | PCE | PCE |
Number of Units in Package 1 | 1 | 1 | 1 | 1 |
Package 1 Height | 36 cm | 35.2 cm | 35.5 cm | 32.0 cm |
Package 1 Width | 30.5 cm | 35.8 cm | 30.5 cm | 46.0 cm |
Package 1 Length | 39 cm | 44.8 cm | 39.0 cm | 42.5 cm |
Package 1 Weight | 10.266 kg | 9.204 kg | 9.27 kg | 13.688 kg |
Unit Type of Package 2 | P06 | P06 | P06 | P06 |
Number of Units in Package 2 | 2 | 2 | 2 | 2 |
Package 2 Height | 73.5 cm | 73.5 cm | 73.5 cm | 73.5 cm |
Package 2 Width | 80 cm | 80.0 cm | 80.0 cm | 80.0 cm |
Package 2 Length | 60 cm | 60.0 cm | 60.0 cm | 60.0 cm |
Package 2 Weight | 33.532 kg | 31.896 kg | 31.774 kg | 41.96 kg |
Contractual warranty | ||||
Warranty | 18 months | 18 months | 18 months | 18 months |
Main | ||||
Part Number |
ATS48C17Q |
ATS48C21Q |
ATS48C25Q |
ATS48C32Q |
Range of product | Altistart 48 | Altistart 48 | Altistart 48 | Altistart 48 |
Product or component type | Soft starter | Soft starter | Soft starter | Soft starter |
Product destination | Asynchronous motors | Asynchronous motors | Asynchronous motors | Asynchronous motors |
Product specific application | Heavy duty industry and pumps | Heavy duty industry and pumps | Heavy duty industry and pumps | Heavy duty industry and pumps |
Device short name | ATS48 | ATS48 | ATS48 | ATS48 |
Utilisation category | AC-53A | AC-53A | AC-53A | AC-53A |
Ue power supply voltage | 230…415 V – 15…10 % | 230…415 V – 15…10 % | 230…415 V – 15…10 % | 230…415 V – 15…10 % |
power supply frequency | 50…60 Hz – 5…5 % | 50…60 Hz – 5…5 % | 50…60 Hz – 5…5 % | 50…60 Hz – 5…5 % |
motor power kW | 75 kW at 230 V connection to the motor delta terminals for severe applications 75 kW at 400 V connection in the motor supply line for severe applications 90 kW at 230 V connection to the motor delta terminals for standard applications 90 kW at 400 V connection in the motor supply line for standard applications 110 kW at 400 V connection to the motor delta terminals for severe applications 132 kW at 400 V connection to the motor delta terminals for standard applications 37 kW at 230 V connection in the motor supply line for severe applications 45 kW at 230 V connection in the motor supply line for standard applications |
55 kW at 230 V connection in the motor supply line for standard applications 90 kW at 230 V connection to the motor delta terminals for severe applications 90 kW at 400 V connection in the motor supply line for severe applications 110 kW at 230 V connection to the motor delta terminals for standard applications 110 kW at 400 V connection in the motor supply line for standard applications 132 kW at 400 V connection to the motor delta terminals for severe applications 160 kW at 400 V connection to the motor delta terminals for standard applications 45 kW at 230 V connection in the motor supply line for severe applications |
55 kW at 230 V connection in the motor supply line for severe applications 75 kW at 230 V connection in the motor supply line for standard applications 110 kW at 230 V connection to the motor delta terminals for severe applications 110 kW at 400 V connection in the motor supply line for severe applications 132 kW at 230 V connection to the motor delta terminals for standard applications 132 kW at 400 V connection in the motor supply line for standard applications 160 kW at 400 V connection to the motor delta terminals for severe applications 220 kW at 400 V connection to the motor delta terminals for standard applications |
75 kW at 230 V connection in the motor supply line for severe applications 90 kW at 230 V connection in the motor supply line for standard applications 132 kW at 230 V connection to the motor delta terminals for severe applications 132 kW at 400 V connection in the motor supply line for severe applications 160 kW at 230 V connection to the motor delta terminals for standard applications 160 kW at 400 V connection in the motor supply line for standard applications 220 kW at 400 V connection to the motor delta terminals for severe applications 250 kW at 400 V connection to the motor delta terminals for standard applications |
Complementary | ||||
Device connection | To the motor delta terminals In the motor supply line |
To the motor delta terminals In the motor supply line |
To the motor delta terminals In the motor supply line |
In the motor supply line To the motor delta terminals |
protection type | Phase failure: line Thermal protection: motor Thermal protection: starter |
Phase failure: line Thermal protection: motor Thermal protection: starter |
Phase failure: line Thermal protection: motor Thermal protection: starter |
Phase failure: line Thermal protection: motor Thermal protection: starter |
Standards | EN/IEC 60947-4-2 | EN/IEC 60947-4-2 | EN/IEC 60947-4-2 | EN/IEC 60947-4-2 |
Product certifications | C-Tick NOM 117 CCC GOST TCF DNV SEPRO CSA UL |
GOST SEPRO CSA C-Tick NOM 117 TCF UL CCC DNV |
C-Tick CCC UL NOM 117 CSA DNV SEPRO GOST TCF |
C-Tick CCC DNV SEPRO NOM 117 CSA TCF GOST UL |
Marking | CE | CE | CE | CE |
Discrete input number | 5 | 5 | 5 | 5 |
discrete input type | PTC, 750 Ohm at 25 °C (Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm |
PTC, 750 Ohm at 25 °C (Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm |
PTC, 750 Ohm at 25 °C (Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm |
PTC, 750 Ohm at 25 °C (Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm |
discrete input logic | Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA | Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA | Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA | Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA |
minimum switching current | 10 mA at 6 V DC for relay outputs | 10 mA at 6 V DC for relay outputs | 10 mA at 6 V DC for relay outputs | 10 mA at 6 V DC for relay outputs |
Discrete output number | 2 | 2 | 2 | 2 |
discrete output type | (LO1) logic output 0 V common configurable (LO2) logic output 0 V common configurable (R1) relay outputs fault relay NO (R2) relay outputs end of starting relay NO (R3) relay outputs motor powered NO |
(LO1) logic output 0 V common configurable (LO2) logic output 0 V common configurable (R1) relay outputs fault relay NO (R2) relay outputs end of starting relay NO (R3) relay outputs motor powered NO |
(LO1) logic output 0 V common configurable (LO2) logic output 0 V common configurable (R1) relay outputs fault relay NO (R2) relay outputs end of starting relay NO (R3) relay outputs motor powered NO |
(LO1) logic output 0 V common configurable (LO2) logic output 0 V common configurable (R1) relay outputs fault relay NO (R2) relay outputs end of starting relay NO (R3) relay outputs motor powered NO |
analogue output type | Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm | Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm | Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm | Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm |
Communication port protocol | Modbus | Modbus | Modbus | Modbus |
connector type | 1 RJ45 | 1 RJ45 | 1 RJ45 | 1 RJ45 |
Communication data link | Serial | Serial | Serial | Serial |
Physical interface | RS485 multidrop | RS485 multidrop | RS485 multidrop | RS485 multidrop |
Transmission rate | 4800, 9600 or 19200 bps | 4800, 9600 or 19200 bps | 4800, 9600 or 19200 bps | 4800, 9600 or 19200 bps |
Function available | External bypass (optional) | External bypass (optional) | External bypass (optional) | External bypass (optional) |
Operating position | Vertical +/- 10 degree | Vertical +/- 10 degree | Vertical +/- 10 degree | Vertical +/- 10 degree |
Height | 340 mm | 380 mm | 380 mm | 380 mm |
Width | 200 mm | 320 mm | 320 mm | 320 mm |
Depth | 265 mm | 265 mm | 265 mm | 265 mm |
Net weight | 12.4 kg | 18.2 kg | 18.2 kg | 18.2 kg |
Environment | ||||
electromagnetic compatibility | Conducted and radiated emissions level A conforming to IEC 60947-4-2 Conducted and radiated emissions level B conforming to IEC 60947-4-2 Damped oscillating waves level 3 conforming to IEC 61000-4-12 Electrostatic discharge level 3 conforming to IEC 61000-4-2 Immunity to electrical transients level 4 conforming to IEC 61000-4-4 Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3 Voltage/current impulse level 3 conforming to IEC 61000-4-5 |
Conducted and radiated emissions level A conforming to IEC 60947-4-2 Damped oscillating waves level 3 conforming to IEC 61000-4-12 Electrostatic discharge level 3 conforming to IEC 61000-4-2 Immunity to electrical transients level 4 conforming to IEC 61000-4-4 Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3 Voltage/current impulse level 3 conforming to IEC 61000-4-5 |
Conducted and radiated emissions level A conforming to IEC 60947-4-2 Damped oscillating waves level 3 conforming to IEC 61000-4-12 Electrostatic discharge level 3 conforming to IEC 61000-4-2 Immunity to electrical transients level 4 conforming to IEC 61000-4-4 Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3 Voltage/current impulse level 3 conforming to IEC 61000-4-5 |
Conducted and radiated emissions level A conforming to IEC 60947-4-2 Damped oscillating waves level 3 conforming to IEC 61000-4-12 Electrostatic discharge level 3 conforming to IEC 61000-4-2 Immunity to electrical transients level 4 conforming to IEC 61000-4-4 Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3 Voltage/current impulse level 3 conforming to IEC 61000-4-5 |
relative humidity | 0…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3 | 0…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3 | 0…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3 | 0…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3 |
ambient air temperature for operation | 40…60 °C (with current derating of 2 % per °C) -10…40 °C (without derating) |
40…60 °C (with current derating of 2 % per °C) -10…40 °C (without derating) |
40…60 °C (with current derating of 2 % per °C) -10…40 °C (without derating) |
40…60 °C (with current derating of 2 % per °C) -10…40 °C (without derating) |
Ambient air temperature for storage | -25…70 °C | -25…70 °C | -25…70 °C | -25…70 °C |
operating altitude | <= 1000 m without derating > 1000…2000 m with current derating of 2.2 % per additional 100 m |
<= 1000 m without derating > 1000…2000 m with current derating of 2.2 % per additional 100 m |
<= 1000 m without derating > 1000…2000 m with current derating of 2.2 % per additional 100 m |
<= 1000 m without derating > 1000…2000 m with current derating of 2.2 % per additional 100 m |
Packing Units | ||||
Unit Type of Package 1 | PCE | PCE | PCE | PCE |
Number of Units in Package 1 | 1 | 1 | 1 | 1 |
Package 1 Height | 43 cm | 72.000 cm | 42.000 cm | 42.500 cm |
Package 1 Width | 33 cm | 80.000 cm | 46.000 cm | 46.000 cm |
Package 1 Length | 46 cm | 60.000 cm | 51.500 cm | 51.000 cm |
Package 1 Weight | 13.816 kg | 21.000 kg | 21.636 kg | 20.000 kg |
Unit Type of Package 2 | P06 | N/A | ||
Number of Units in Package 2 | 2 | |||
Package 2 Height | 73.5 cm | |||
Package 2 Width | 80 cm | |||
Package 2 Length | 60 cm | |||
Package 2 Weight | 40 kg | |||
Contractual warranty | ||||
Warranty | 18 months | 18 months | 18 months | 18 months |
Main | |||
Part Number |
ATS48C32Y |
ATS48C41Q |
ATS48C48Q |
Range of product | Altistart 48 | Altistart 48 | Altistart 48 |
Product or component type | Soft starter | Soft starter | Soft starter |
Product destination | Asynchronous motors | Asynchronous motors | Asynchronous motors |
Product specific application | Heavy duty industry and pumps | Heavy duty industry and pumps | Heavy duty industry and pumps |
Device short name | ATS48 | ATS48 | ATS48 |
Utilisation category | AC-53A | AC-53A | AC-53A |
Ue power supply voltage | 208…690 V – 15…10 % | 230…415 V – 15…10 % | 230…415 V – 15…10 % |
power supply frequency | 50…60 Hz – 5…5 % | 50…60 Hz – 5…5 % | 50…60 Hz – 5…5 % |
motor power kW | 132 kW at 400 V for severe applications 132 kW at 440 V for severe applications 160 kW at 400 V for standard applications 160 kW at 440 V for standard applications 160 kW at 500 V for severe applications 160 kW at 525 V for severe applications 220 kW at 500 V for standard applications 220 kW at 525 V for standard applications 220 kW at 660 V for severe applications 250 kW at 660 V for standard applications 250 kW at 690 V for severe applications 315 kW at 690 V for standard applications 75 kW at 230 V for severe applications 90 kW at 230 V for standard applications |
90 kW at 230 V connection in the motor supply line for severe applications 110 kW at 230 V connection in the motor supply line for standard applications 160 kW at 230 V connection to the motor delta terminals for severe applications 160 kW at 400 V connection in the motor supply line for severe applications 220 kW at 230 V connection to the motor delta terminals for standard applications 220 kW at 400 V connection in the motor supply line for standard applications 250 kW at 400 V connection to the motor delta terminals for severe applications 315 kW at 400 V connection to the motor delta terminals for standard applications |
110 kW at 230 V connection in the motor supply line for severe applications 132 kW at 230 V connection in the motor supply line for standard applications 220 kW at 230 V connection to the motor delta terminals for severe applications 220 kW at 400 V connection in the motor supply line for severe applications 250 kW at 230 V connection to the motor delta terminals for standard applications 250 kW at 400 V connection in the motor supply line for standard applications 315 kW at 400 V connection to the motor delta terminals for severe applications 355 kW at 400 V connection to the motor delta terminals for standard applications |
motor power hp | 100 hp at 208 V for standard applications 100 hp at 230 V for severe applications 125 hp at 230 V for standard applications 200 hp at 460 V for severe applications 250 hp at 460 V for standard applications 250 hp at 575 V for severe applications 300 hp at 575 V for standard applications 75 hp at 208 V for severe applications |
||
Complementary | |||
Device connection | In the motor supply line | In the motor supply line To the motor delta terminals |
To the motor delta terminals In the motor supply line |
protection type | Phase failure: line Thermal protection: motor Thermal protection: starter |
Phase failure: line Thermal protection: motor Thermal protection: starter |
Phase failure: line Thermal protection: motor Thermal protection: starter |
Standards | EN/IEC 60947-4-2 | EN/IEC 60947-4-2 | EN/IEC 60947-4-2 |
Product certifications | C-Tick NOM 117 SEPRO CSA UL CCC TCF DNV GOST |
DNV C-Tick CSA NOM 117 TCF UL SEPRO GOST CCC |
CSA GOST DNV TCF UL C-Tick NOM 117 CCC SEPRO |
Marking | CE | CE | CE |
Discrete input number | 5 | 5 | 5 |
discrete input type | PTC, 750 Ohm at 25 °C (Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm |
PTC, 750 Ohm at 25 °C (Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm |
PTC, 750 Ohm at 25 °C (Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm |
discrete input logic | Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA | Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA | Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA |
minimum switching current | 10 mA at 6 V DC for relay outputs | 10 mA at 6 V DC for relay outputs | 10 mA at 6 V DC for relay outputs |
Discrete output number | 2 | 2 | 2 |
discrete output type | (LO1) logic output 0 V common configurable (LO2) logic output 0 V common configurable (R1) relay outputs fault relay NO (R2) relay outputs end of starting relay NO (R3) relay outputs motor powered NO |
(LO1) logic output 0 V common configurable (LO2) logic output 0 V common configurable (R1) relay outputs fault relay NO (R2) relay outputs end of starting relay NO (R3) relay outputs motor powered NO |
(LO1) logic output 0 V common configurable (LO2) logic output 0 V common configurable (R1) relay outputs fault relay NO (R2) relay outputs end of starting relay NO (R3) relay outputs motor powered NO |
analogue output type | Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm | Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm | Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm |
Communication port protocol | Modbus | Modbus | Modbus |
connector type | 1 RJ45 | 1 RJ45 | 1 RJ45 |
Communication data link | Serial | Serial | Serial |
Physical interface | RS485 multidrop | RS485 multidrop | RS485 multidrop |
Transmission rate | 4800, 9600 or 19200 bps | 4800, 9600 or 19200 bps | 4800, 9600 or 19200 bps |
Function available | External bypass (optional) | External bypass (optional) | External bypass (optional) |
Operating position | Vertical +/- 10 degree | Vertical +/- 10 degree | Vertical +/- 10 degree |
Height | 380 mm | 670 mm | 670 mm |
Width | 320 mm | 400 mm | 400 mm |
Depth | 265 mm | 300 mm | 300 mm |
Net weight | 18.2 kg | 51.4 kg | 51.4 kg |
Environment | |||
electromagnetic compatibility | Conducted and radiated emissions level A conforming to IEC 60947-4-2 Damped oscillating waves level 3 conforming to IEC 61000-4-12 Electrostatic discharge level 3 conforming to IEC 61000-4-2 Immunity to electrical transients level 4 conforming to IEC 61000-4-4 Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3 Voltage/current impulse level 3 conforming to IEC 61000-4-5 |
Conducted and radiated emissions level A conforming to IEC 60947-4-2 Damped oscillating waves level 3 conforming to IEC 61000-4-12 Electrostatic discharge level 3 conforming to IEC 61000-4-2 Immunity to electrical transients level 4 conforming to IEC 61000-4-4 Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3 Voltage/current impulse level 3 conforming to IEC 61000-4-5 |
Conducted and radiated emissions level A conforming to IEC 60947-4-2 Damped oscillating waves level 3 conforming to IEC 61000-4-12 Electrostatic discharge level 3 conforming to IEC 61000-4-2 Immunity to electrical transients level 4 conforming to IEC 61000-4-4 Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3 Voltage/current impulse level 3 conforming to IEC 61000-4-5 |
relative humidity | 0…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3 | 0…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3 | 0…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3 |
ambient air temperature for operation | 40…60 °C (with current derating of 2 % per °C) -10…40 °C (without derating) |
40…60 °C (with current derating of 2 % per °C) -10…40 °C (without derating) |
40…60 °C (with current derating of 2 % per °C) -10…40 °C (without derating) |
Ambient air temperature for storage | -25…70 °C | -25…70 °C | -25…70 °C |
operating altitude | <= 1000 m without derating > 1000…2000 m with current derating of 2.2 % per additional 100 m |
<= 1000 m without derating > 1000…2000 m with current derating of 2.2 % per additional 100 m |
<= 1000 m without derating > 1000…2000 m with current derating of 2.2 % per additional 100 m |
Packing Units | |||
Unit Type of Package 1 | PCE | PCE | PCE |
Number of Units in Package 1 | 1 | 1 | 1 |
Package 1 Height | 75.000 cm | 39 cm | 39 cm |
Package 1 Width | 60.000 cm | 58 cm | 60 cm |
Package 1 Length | 80.000 cm | 78.5 cm | 78 cm |
Package 1 Weight | 33.000 kg | 54.5 kg | 53.5 kg |
Contractual warranty | |||
Warranty | 18 months | 18 months | 18 months |
Main | |||
Part Number | ATS48D17Q | ATS48C59Q | ATS48C79Q |
Range of product | Altistart 48 | Altistart 48 | Altistart 48 |
Product or component type | Soft starter | Soft starter | Soft starter |
Product destination | Asynchronous motors | Asynchronous motors | Asynchronous motors |
Product specific application | Heavy duty industry and pumps | Heavy duty industry and pumps | Heavy duty industry and pumps |
Device short name | ATS48 | ATS48 | ATS48 |
utilisation category | AC-53A | AC-53A | AC-53A |
Ue power supply voltage | 230…415 V – 15…10 % | 230…415 V – 15…10 % | 230…415 V – 15…10 % |
power supply frequency | 50…60 Hz – 5…5 % | 50…60 Hz – 5…5 % | 50…60 Hz – 5…5 % |
Motor power kW | 7.5 kW at 230 V connection to the motor delta terminals for standard applications | 132 kW at 230 V connection in the motor supply line for severe applications | 630 kW at 400 V connection to the motor delta terminals for standard applications |
7.5 kW at 400 V connection in the motor supply line for standard applications | 160 kW at 230 V connection in the motor supply line for standard applications | 220 kW at 230 V connection in the motor supply line for standard applications | |
11 kW at 400 V connection to the motor delta terminals for severe applications | 250 kW at 230 V connection to the motor delta terminals for severe applications | 315 kW at 230 V connection to the motor delta terminals for severe applications | |
15 kW at 400 V connection to the motor delta terminals for standard applications | 250 kW at 400 V connection in the motor supply line for severe applications | 355 kW at 230 V connection to the motor delta terminals for standard applications | |
3 kW at 230 V connection in the motor supply line for severe applications | 315 kW at 400 V connection in the motor supply line for standard applications | 355 kW at 400 V connection in the motor supply line for severe applications | |
4 kW at 230 V connection in the motor supply line for standard applications | 355 kW at 400 V connection to the motor delta terminals for severe applications | 400 kW at 400 V connection in the motor supply line for standard applications | |
5.5 kW at 230 V connection to the motor delta terminals for severe applications | 400 kW at 400 V connection to the motor delta terminals for standard applications | 500 kW at 400 V connection to the motor delta terminals for severe applications | |
5.5 kW at 400 V connection in the motor supply line for severe applications | |||
Complementary | |||
Device connection | To the motor delta terminals | To the motor delta terminals | In the motor supply line |
In the motor supply line | In the motor supply line | To the motor delta terminals | |
Protection type | Phase failure: line | Phase failure: line | Phase failure: line |
Thermal protection: motor | Thermal protection: motor | Thermal protection: motor | |
Thermal protection: starter | Thermal protection: starter | Thermal protection: starter | |
Standards | EN/IEC 60947-4-2 | EN/IEC 60947-4-2 | EN/IEC 60947-4-2 |
Product certifications | UL | TCF | SEPRO |
CCC | DNV | C-Tick | |
GOST | UL | TCF | |
DNV | CCC | GOST | |
CSA | CSA | UL | |
NOM 117 | NOM 117 | CCC | |
SEPRO | SEPRO | CSA | |
TCF | GOST | DNV | |
C-Tick | C-Tick | NOM 117 | |
marking | CE | CE | CE |
Discrete input number | 5 | 5 | 5 |
Discrete input type | PTC, 750 Ohm at 25 °C | PTC, 750 Ohm at 25 °C | PTC, 750 Ohm at 25 °C |
(Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm | (Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm | (Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm | |
Discrete input logic | Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA | Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA | Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA |
Minimum switching current | 10 mA at 6 V DC for relay outputs | 10 mA at 6 V DC for relay outputs | 10 mA at 6 V DC for relay outputs |
Discrete output number | 2 | 2 | 2 |
Discrete output type | (LO1) logic output 0 V common configurable | (LO1) logic output 0 V common configurable | (LO1) logic output 0 V common configurable |
(LO2) logic output 0 V common configurable | (LO2) logic output 0 V common configurable | (LO2) logic output 0 V common configurable | |
(R1) relay outputs fault relay NO | (R1) relay outputs fault relay NO | (R1) relay outputs fault relay NO | |
(R2) relay outputs end of starting relay NO | (R2) relay outputs end of starting relay NO | (R2) relay outputs end of starting relay NO | |
(R3) relay outputs motor powered NO | (R3) relay outputs motor powered NO | (R3) relay outputs motor powered NO | |
Analogue output type | Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm | Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm | Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm |
Communication port protocol | Modbus | Modbus | Modbus |
Connector type | 1 RJ45 | 1 RJ45 | 1 RJ45 |
Communication data link | Serial | Serial | Serial |
Physical interface | RS485 multidrop | RS485 multidrop | RS485 multidrop |
Transmission rate | 4800, 9600 or 19200 bps | 4800, 9600 or 19200 bps | 4800, 9600 or 19200 bps |
Function available | External bypass (optional) | External bypass (optional) | External bypass (optional) |
Operating position | Vertical +/- 10 degree | Vertical +/- 10 degree | Vertical +/- 10 degree |
Height | 275 mm | 670 mm | 890 mm |
Width | 160 mm | 400 mm | 770 mm |
Depth | 190 mm | 300 mm | 315 mm |
Net weight | 4.9 kg | 51.4 kg | 115 kg |
Environment | |||
Electromagnetic compatibility | Conducted and radiated emissions level A conforming to IEC 60947-4-2 | Conducted and radiated emissions level A conforming to IEC 60947-4-2 | Conducted and radiated emissions level A conforming to IEC 60947-4-2 |
Conducted and radiated emissions level B conforming to IEC 60947-4-2 | Damped oscillating waves level 3 conforming to IEC 61000-4-12 | Damped oscillating waves level 3 conforming to IEC 61000-4-12 | |
Damped oscillating waves level 3 conforming to IEC 61000-4-12 | Electrostatic discharge level 3 conforming to IEC 61000-4-2 | Electrostatic discharge level 3 conforming to IEC 61000-4-2 | |
Electrostatic discharge level 3 conforming to IEC 61000-4-2 | Immunity to electrical transients level 4 conforming to IEC 61000-4-4 | Immunity to electrical transients level 4 conforming to IEC 61000-4-4 | |
Immunity to electrical transients level 4 conforming to IEC 61000-4-4 | Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3 | Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3 | |
Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3 | Voltage/current impulse level 3 conforming to IEC 61000-4-5 | Voltage/current impulse level 3 conforming to IEC 61000-4-5 | |
Voltage/current impulse level 3 conforming to IEC 61000-4-5 | |||
Relative humidity | 0…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3 | 0…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3 | 0…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3 |
Ambient air temperature for operation | 40…60 °C (with current derating of 2 % per °C) | 40…60 °C (with current derating of 2 % per °C) | 40…60 °C (with current derating of 2 % per °C) |
-10…40 °C (without derating) | -10…40 °C (without derating) | -10…40 °C (without derating) | |
Ambient air temperature for storage | -25…70 °C | -25…70 °C | -25…70 °C |
Operating altitude | <= 1000 m without derating | <= 1000 m without derating | <= 1000 m without derating |
> 1000…2000 m with current derating of 2.2 % per additional 100 m | > 1000…2000 m with current derating of 2.2 % per additional 100 m | > 1000…2000 m with current derating of 2.2 % per additional 100 m | |
Packing Units | |||
Unit Type of Package 1 | PCE | PCE | PCE |
Number of Units in Package 1 | 1 | 1 | 1 |
Package 1 Height | 27.0 cm | 39.0 cm | 61.000 cm |
Package 1 Width | 25.0 cm | 58.5 cm | 91.000 cm |
Package 1 Length | 35.0 cm | 78.0 cm | 103.000 cm |
Package 1 Weight | 5.682 kg | 53.025 kg | 123.000 kg |
Unit Type of Package 2 | P06 | P06 | |
Number of Units in Package 2 | 8 | 1 | |
Package 2 Height | 73.5 cm | 52.0 cm | |
Package 2 Width | 80.0 cm | 54.0 cm | |
Package 2 Length | 60.0 cm | 82.0 cm | |
Package 2 Weight | 58.456 kg | 62.94 kg | |
Contractual warranty | |||
Warranty | 18 months | 18 months | 18 months |
Weight | N/A |
---|---|
Dimensions | N/A |