$ 218.50 – $ 231.84
Product Number | LS-501-C2 |
---|---|
Part Number | LS-501-C2 |
Products Name | Amplifier-separated Type Digital Laser Sensor |
Product details | Amplifiers(Cable type) |
The price of the product | Please contact our office |
Applicable regulations | EMC Directive, RoHS Directive |
Operation indicator | Orange LED (lights up when sensing output 1 or sensing output 2 is ON) |
Protection | IP40(IEC) |
Ambient temperature | -10 to +55degrees + 14 to 131 degrees Fahrenheit (If 4 to 7 units are mounted close together, -10 to +50 degrees +14 to +122 degrees Fahrenheit ; if 8 to 12 units are mounted close together, -10 to +45 degrees +14 to +113 degrees Fahrenheit )(No dew condensation or icing allowed), Storage: -20 to +70 degrees -4 to +158 degrees Fahrenheit |
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
Voltage withstandability | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
Insulation resistance | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure |
Vibration resistance | 10 to 150 Hz frequency, 1.5 mm 0.059 in double amplitude or maximum acceleration 98 m/s2 in X, Y and Z directions for two hours each |
Shock resistance | 98 m/s2 acceleration (10 G approx.) in X, Y and Z directions for five times each |
Material | Enclosure: Polycarbonate Cover: Polycarbonate Switch: Polyacetal |
Cable | 0.2mm2 6-core cabtyre cable, 2 m 6.562 ft long |
Weight | Net weight: 75 g approx. Gross weight: 110 g approx. |
Accessory | FX-MB1 (Amplifier protective seal): 1 set |
Supply voltage | 12 to 24 V DC +10-15% Ripple P-P 10 % or less |
Power consumption | Normal operation: 1,200 mW or less (Current consumption 50 mA or less at 24 V supply voltage,excluding monitor current output) ECO mode: 980 mW or less (Current consumption 40 mA or less at 24 V supply voltage,excluding monitor current output) |
Sensing outputs (Sensing output 1, 2) | NPN open-collector transistor ・Maximum sink current: 50 mA (Note:25 mA if 5 or more amplifier are connected in cascade (excluding cable extension).) ・Applied voltage: 30 V DC or less (between output and 0 V) ・Residual voltage: 2 V or less (at max. sink current) (Note:Select either sensing output 2 or external input as the connector type.) |
Sensing outputs (Sensing output 1, 2):Output operation | Selectable either Light-ON or Dark-ON |
Sensing outputs (Sensing output 1, 2):Short-circuit protection | Incorporated |
Sensing output setting:Sensing output 1 | Normal mode, differential mode, hysteresis mode, window comparator mode, selectable |
Sensing output setting:Sensing output 2 | Normal mode, differential mode, hysteresis mode, self-diagnostic output mode, answer-back output mode, selectable (Note:Select either sensing output 2 or external input.) |
Response time | H-SP: 60 micro s or less, FAST: 150 micro s or less, STD: 250 micro s or less, LONG: 500 micro s or less, U-LG: 5 ms or less, HYPR: 24 ms or less selectable |
Monitor current output | Output current: Approx. 4 to 20 mA (H-SP, FAST, STD: at 0 to 4,000 indication) Response time: 2 ms or less Zero point: 4 mA plus or minus 1 % F.S. Span: 16 mA plus or minus 5 % F.S. Linearity: plus or minus 3 % F.S. Load resistance: 0 to 250 Ohm |
External input | NPN non-contact input – Signal condition High: +8 V to +V DC or open, Low: 0 to +2 V DC (source current 0.5 mA or less) – Input impedance: 10 kOhm approx.(Note:Select either sensing output 2 or external input.) |
External input function | Laser emission halt / teaching (full-auto teaching, limit teaching, 2 point teaching) / logic operation setting / copy lock /display adjustment / data bank load / data bank save, selectable |
Laser emission indicator | Green LED (lights up during laser emission) |
Output select indicator | Yellow LED (lights up when output is selected) |
Digital display | 8-digit 7-segment digital display (4-digit green LED + 4-digit red LED), MODE indicator (Yellow LED): L/D, CUST, PRO |
Incident light indication range | H-SP/FAST/STD: 0 to 4,000 LONG/U-LG/HYPR: 0 to 9,999 |
Sensitivity setting | 2-level teaching / limit teaching / full auto teaching / manual adjustment |
Logical operation | Between sensing output 1 and calculation target: Disabled / and / or / xor, selectable Calculation target: Sensing output 2 / adjacent upstream amplifier (sensing output 1) / external input, selectable |
Timer function |
OFF-delay timer, ON-delay timer, ONE-SHOT timer, ON / OFF-delay timer, ON-delay / ONE-SHOT timer, switchable either effective of ineffective, with variable timer period OFF-delay timer, ON-delay timer, ONE-SHOT timer, |
Timer function:Time | Timer range ” ms”: 0.5 ms approx., 1 to 9,999 ms approx., in approx. 1 ms intervals Timer range ” sec”: 0.5 sec. approx., 1 to 32 sec. approx., in approx. 1 sec. intervals Timer range ” 1/10 ms”: 0.05 ms approx., 0.1 to 999.9 ms approx., in approx. 0.1 ms intervals, Set separately for each output. |
Automatic interference prevention function | Incorporated (Note:Number of units that can be mounted close together: 0 for H-SP; 2 for FAST; 4 for STD, LONG, U-LG, or HYPR) |
Cable extension | Extension up to total 100 m 328.084 ft is possible with 0.3mm2, or more, cable. |
Product Number | LS-H901 |
---|---|
Part Number | LS-H901 |
Products Name | Amplifier-separated Type Digital Laser Sensor |
Product details | Sensor heads(Coaxial retroreflective type) |
The price of the product | Please contact our office |
Applicable regulations | EMC Directive, RoHS Directive |
Applicable amplifiers | LS-501(P), LS-501(P)-C2 (Note:When using the thru-beam type LS-H101□ or LS-H102□, do not set the receiving light sensitivity (gctL) of the applicable LS-500 series amplifier to level 2 or less. This is because there is a possibility of sensing becoming unstable.) |
Sensing range:H-SP mode | 0.01 to 1m 0.033 to 3.281 ft (Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm 3.937 × 3.937 in) as the object.) (Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m 0.033 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicable LS-500 series amplifiers, leave an adequate safety margin when setting the threshold.) |
Sensing range:FAST mode | 0.01 to 1m 0.033 to 3.281 ft (Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm 3.937 × 3.937 in) as the object.) (Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m 0.033 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicable LS-500 series amplifiers, leave an adequate safety margin when setting the threshold.) |
Sensing range:STD mode | 0.01 to 1m 0.033 to 3.281 ft (Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm 3.937 × 3.937 in) as the object.) (Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m 0.033 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicable LS-500 series amplifiers, leave an adequate safety margin when setting the threshold.) |
Sensing range:U-LG mode | 0.01 to 1.5m 0.033 to 4.921 ft (Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm 3.937 × 3.937 in) as the object.) (Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m 0.033 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicable LS-500 series amplifiers, leave an adequate safety margin when setting the threshold.) |
Sensing range:U-LG | 0.01 to 2m 0.033 to 6.562 ft (Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm 3.937 × 3.937 in) as the object.) (Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m 0.033 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicable LS-500 series amplifiers, leave an adequate safety margin when setting the threshold.) |
Sensing range:HYPR | 0.01 to 2.5m 0.033 to 8.202 ft (Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm 3.937 × 3.937 in) as the object.) (Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m 0.033 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicable LS-500 series amplifiers, leave an adequate safety margin when setting the threshold.) |
Spot size | Approx. dia. 6 mm dia. 0.236 in or less (at a distance from the sensor head of 1 m 3.281 ft) |
Sensing object | Opaque, translucent, or transparent object (Note:Make sure to confirm detection with an actual sensor before use.) |
Operation indicator | Orange LED (lights up when the amplifier output is ON) |
Protection | IP40 (IEC) |
Ambient temperature | -10 to +55degrees + 14 to + 131 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -20 to +70degrees -4 to +158 degrees Fahrenheit |
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
Ambient illuminance | Incandescent light: 3,000 ℓx or less at the light-receiving face |
Voltage withstandability | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
Insulation resistance | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure |
Vibration resistance | 10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude or maximum acceleration 98 m/s2 in X, Y and Z directions for two hours each |
Shock resistance | 98 m / s2 acceleration (10 G approx.) in X, Y and Z directions three times each |
Emitting element:Type | Red semiconductor laser diode |
Emitting element:Peak emission wavelength | 660 nm 0.026 mil |
Emitting element:Laser class | Class 1 [IEC / EN / JIS / GB / KS / FDA] (Note:This product complies with the FDA regulations (FDA 21 CFR 1040.10 and 1040.11) in accordance with FDA Laser Notice No. 56, except for complying with IEC 60825-1 Ed. 3. |
Emitting element:Max. output | 1mW |
Material | Enclosure: PBT Indicator cover: Polycarbonate Beam-emitting / receiving surfaces: Glass |
Cable | 0.09 mm2 2-core two parallel shielded cables, 2 m 6.562 ft long (Note:Cable cannot be extended.) |
Weight | Net weight: 50 g approx. Gross weight: 85 g approx. |
Accessory | MS-LS-1(Mounting bracket): 1pc. RF-330(Refrector): 1pc. |
INOSAKI Limited
RM B 5/F Gaylord Comm,
Bldg 114-118 Lockhart Rd.
Hong Kong
INOSAKI Sdn. Bhd.
2-1-9, Ground Floor, One Square, Tingkat Mahsuri 1,
11900 Bayan Lepas, Penang
INOSAKI Pte. Ltd.
101 Upper Cross Street,
No. 06-17, People’s Park Centre,
Singapore (058357)