CPX-AP-I-4DI4DO-M8-3P – Digital Input/Output Module – Festo Remote I/O and Network Interface Components
$ 560.05
Manufacturer Part Number: Festo 8086601
Festo Remote I/O and Network Interface Components: CPX-AP-I-4DI4DO-M8-3P
OEM Spec Ref
The Festo CPX-AP-I-4DI4DO-M8-3P, with MPN 8086601, is an innovative remote I/O and network interface component module designed to enhance the functionality and integration of automation systems. This module is engineered to provide both input and output capabilities, making it a versatile component for various industrial applications.
Key Features:
- Hybrid Functionality: Equipped with 4 digital inputs and 4 digital outputs, enabling efficient data acquisition and control within a single compact module.
- M8 Connectors: Utilizes M8 connectors for secure and reliable connections, ensuring robust communication in harsh industrial environments.
- Compact and Modular Design: Offers a sleek, compact design that is easily integrated into existing systems without requiring excessive space, making it ideal for applications with limited space.
- Easy Configuration: Supports plug-and-play installation and is easily configurable, reducing setup times and simplifying maintenance.
- Advanced Network Compatibility: Compatible with major industrial communication protocols, which facilitates seamless integration into diverse control systems.
Benefits:
- Enhanced System Efficiency: Improves the overall efficiency and responsiveness of automation systems by consolidating input and output functions into a single device.
- Cost-Effective: Reduces the need for additional components and minimizes wiring complexity, leading to lower installation and maintenance costs.
- Increased Reliability: Engineered to meet high standards of durability and reliability, ensuring long-term performance in demanding industrial settings.
- Flexible Integration: Offers excellent flexibility in system design, allowing for expansion and adaptation as system requirements evolve.
Applications:
- Manufacturing Automation: Ideal for automated production lines where precise control and data acquisition are essential for operational efficiency.
- Process Control Systems: Suitable for process industries requiring tight integration of sensors and actuators with the control system.
- Testing and Inspection: Provides the necessary I/O capabilities for testing equipment and inspection systems in various industrial sectors.
- General Industrial Automation: Can be used in a wide range of industrial applications, enhancing the precision and reliability of pneumatic and automation systems.
The Festo CPX-AP-I-4DI4DO-M8-3P remote I/O and network interface component stands as a testament to Festo’s commitment to advancing industrial automation technology, offering a compact, efficient, and reliable solution for managing network interfaces and optimizing the performance of complex systems.
Technical Data
Feature | Specification |
---|---|
Dimensions W x L x H | 30 mm x 170 mm x 35 mm |
Type of mounting | On H-rail with accessories With through-hole |
Product weight | 129 g |
Ambient temperature | -20 °C … 50 °C |
Storage temperature | -40 °C … 70 °C |
Relative air humidity | 5 – 95 % Non-condensing |
Degree of protection | IP65 IP67 |
Note on degree of protection | Unused connections sealed |
Corrosion resistance class (CRC) | 1 – Low corrosion stress |
Max. cable length | 30 m outputs 30 m inputs 50 m system communication |
Information on max. cable length | Power supply according to nominal voltage |
LABS (PWIS) conformity | VDMA24364-B2-L |
CE marking (see declaration of conformity) | As per EU EMC directive |
UKCA marking (see declaration of conformity) | To UK instructions for EMC |
KC characters | KC EMC |
Certification | RCM compliance mark c UL us – Listed (OL) |
Certificate issuing authority | UL E239998 |
Note on materials | RoHS-compliant |
Housing material | PA PC Die-cast zinc, nickel-plated |
O-ring material | FPM |
Diagnostics via LED | Diagnostics per module Load power supply Status per channel |
Diagnose per internal communication | Load switch-off Short-circuit/overload in output signal Short circuit/overload in sensor supply Electronics/sensors overvoltage Load overvoltage Electronics/sensors undervoltage Load undervoltage |
No. of outputs | 4 |
Communication interface, function | System communication XF10 IN / XF20 OUT |
Communication interface, connection type | 2x socket |
Communication interface, connection technology | M8x1, D-coded as per EN 61076-2-114 |
Communication interface, number of pins/wires | 4 |
Communication interface, protocol | AP |
Communication interface, shielding | yes |
Power supply, function | Incoming electronics/sensors and load |
Power supply, type of connection | Plug |
Power supply, connection technology | M8x1, A-coded as per EN 61076-2-104 |
Power supply, number of pins/wires | 4 |
Voltage forwarding, function | Outgoing electronics/sensors and load |
Voltage forwarding, connection type | Socket |
Voltage forwarding, connection technology | M8x1, A-coded as per EN 61076-2-104 |
Voltage forwarding, number of pins/wires | 4 |
Note regarding operating voltage | SELV/PELV fixed power supplies required Note voltage drop |
Note voltage drop | Nominal operating voltage DC load |
Nominal operating voltage DC load | 24 V |
Permissible voltage fluctuations load | ± 25 % |
Nominal operating voltage DC for electronics/sensors | 24 V |
Permissible voltage fluctuations for electronics/sensors | ± 25 % |
Max. power supply | 2 x 4 A (external fuse required) |
Intrinsic current consumption at nominal operating voltage for electronics/sensors | Typically 35 mA |
Intrinsic current consumption at nominal operating voltage load | Typically 10 mA |
Power failure buffering | 10 ms |
Reverse polarity protection | yes |
Electrical connection input, function | Digital input |
Electrical connection input, connection type | 4x socket |
Electrical input connection, connection technology | M8x1, A-coded as per EN 61076-2-104 |
Electrical connection, input, number of pins/wires | 3 |
No. of inputs | 4 |
Input characteristics | As per IEC 61131-2, type 3 |
Switching level | Signal 0: <= 5 V Signal 1: >= 11 V |
Input switching logic | PNP (positive switching) 2-wire sensors as per IEC 61131-2 3-wire sensors as per IEC 61131-2 |
Input debounce time | 0.1 ms 3 ms 10 ms 20 ms |
Fuse protection inputs (short circuit) | Internal electronic fuse per module |
Max. residual current of inputs per module | 1.8 A |
Electrical isolation of inputs between channels | no |
Digital inputs, electrical isolation of input – internal communication | yes |
Electrical connection output, function | Digital output |
Electrical connection output, connection type | 4x socket |
Electrical connection output, connection technology | M8x1, A-coded as per EN 61076-2-104 |
Electrical output connection, number of pins/wires | 3 |
Characteristic curve outputs | As per IEC 61131-2, type 0.5 |
Switching logic at outputs | PNP (positive switching) |
Fuse protection outputs (short circuit) | Internal electronic fuse per channel |
Output delay with resistive load | Signal change 0->1: < 200 µs Signal change 1->0: < 200 µs |
Max. residual current of outputs per module | 2 A |
Electrical isolation of outputs between channels | no |
Electrical isolation of outputs between channel – internal communication | yes |
Max. power supply per channel | 0.5 A |
Weight | 0.129 kg |
---|---|
Dimensions | 3.0 × 17.0 × 3.5 cm |