E5DC / E5DC-B – General-purpose – Omron Temperature Controllers
$ 354.86
Models with Screw Terminal Blocks
List of Models
Control output |
No. of auxiliary outputs |
Options | Model | Model | ||
---|---|---|---|---|---|---|
HB alarm and HS alarm |
No. of event inputs |
Commu- nications |
Power supply voltage | Power supply voltage | ||
100 to 240 VAC | 24 VAC/DC | |||||
Relay output | — | — | — | RS-485 | E5DC-RX0ASM-015 | E5DC-RX0DSM-015 |
E5DC-RX0AUM-015 | E5DC-RX0DUM-015 | |||||
2 | — | E5DC-RX2ASM-000 | E5DC-RX2DSM-000 | |||
E5DC-RX2AUM-000 | E5DC-RX2DUM-000 | |||||
Detection for single-phase heater |
RS-485 | E5DC-RX2ASM-002 | E5DC-RX2DSM-002 | |||
E5DC-RX2AUM-002 | E5DC-RX2DUM-002 | |||||
1 | — | E5DC-RX2ASM-017 | E5DC-RX2DSM-017 | |||
E5DC-RX2AUM-017 | E5DC-RX2DUM-017 | |||||
Voltage output (for driving SSR) |
— | — | — | RS-485 | E5DC-QX0ASM-015 | E5DC-QX0DSM-015 |
E5DC-QX0AUM-015 | E5DC-QX0DUM-015 | |||||
2 | — | E5DC-QX2ASM-000 | E5DC-QX2DSM-000 | |||
E5DC-QX2AUM-000 | E5DC-QX2DUM-000 | |||||
Detection for single-phase heater |
RS-485 | E5DC-QX2ASM-002 | E5DC-QX2DSM-002 | |||
E5DC-QX2AUM-002 | E5DC-QX2DUM-002 | |||||
1 | — | E5DC-QX2ASM-017 | E5DC-QX2DSM-017 | |||
E5DC-QX2AUM-017 | E5DC-QX2DUM-017 | |||||
Linear current output |
— | — | — | RS-485 | E5DC-CX0ASM-015 | E5DC-CX0DSM-015 |
E5DC-CX0AUM-015 | E5DC-CX0DUM-015 | |||||
2 | — | E5DC-CX2ASM-000 | E5DC-CX2DSM-000 | |||
E5DC-CX2AUM-000 | E5DC-CX2DUM-000 | |||||
RS-485 | E5DC-CX2ASM-015 | E5DC-CX2DSM-015 | ||||
E5DC-CX2AUM-015 | E5DC-CX2DUM-015 | |||||
1 | — | E5DC-CX2ASM-016 | E5DC-CX2DSM-016 | |||
E5DC-CX2AUM-016 | E5DC-CX2DUM-016 |
Ratings
Power supply voltage | A in model number: 100 to 240 VAC, 50/60 Hz D in model number: 24 VAC, 50/60 Hz; 24 VDC |
|
---|---|---|
Operating voltage range | 85 to 110% of rated supply voltage | |
Power consumption | 4.9 VA max. at 100 to 240 VAC, and 2.8 VA max. at 24 VDC or 1.5 W max. at 24 VDC | |
Sensor input | Temperature input Thermocouple: K, J, T, E, L, U, N, R, S, B, C/W, or PL II Platinum resistance thermometer: Pt100 or JPt100 Infrared temperature sensor (ES1B): 10 to 70°C, 60 to 120°C, 115 to 165°C, or 140 to 260°C Analog input Current input: 4 to 20 mA or 0 to 20 mA Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V |
|
Input impedance | Current input: 150 Ω max., Voltage input: 1 MΩ min. (Use a 1:1 connection when connecting the ES2-HB-N/THB-N.) |
|
Control method | ON/OFF control or 2-PID control (with auto-tuning) | |
Control output |
Relay output | SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, minimum applicable load: 5 V, 10 mA (reference value) |
Voltage output (for driving SSR) |
Output voltage 12 VDC ±20% (PNP), max. Load current: 21 mA, with short-circuit protection circuit |
|
Linear current output |
4 to 20 mA DC/0 to 20 mA DC, load: 500 Ω max., resolution: Approx. 10,000 | |
Auxiliary output |
Number of outputs | 2 (depends on model) |
Output specifications |
SPST-NO relay outputs: 250 VAC, 2 A (resistive load), Electrical life: 100,000 operations, Minimum applicable load: 10 mA at 5 V (reference value) |
|
Event input *1 |
Number of inputs | 1 (depends on model) |
External contact input specifications |
Contact input ON: 1 kΩ max., OFF: 100 kΩ min. | |
Non-contact input ON: Residual voltage 1.5 V max.; OFF: Leakage current 0.1 mA max. | ||
Current flow: approx. 7 mA per contact | ||
Setting method | Digital setting using front panel keys | |
Indication method | 11-segment digital displays and individual indicators Character height: PV: 8.5 mm, SV: 8.0 mm |
|
Multi SP | Up to eight set points (SP0 to SP7) can be saved and selected using the event inputs, key operations, or serial communications. *2 |
|
Bank switching | None | |
Other functions | Manual output, heating/cooling control, loop burnout alarm, SP ramp, other alarm functions, heater burnout (HB) alarm (including SSR failure (HS) alarm), 40% AT, 100% AT, MV limiter, input digital filter, self tuning, robust tuning, PV input shift, run/ stop, protection functions, extraction of square root, MV change rate limit, logic operations, temperature status display, simple programming, moving average of input value, display brightness setting, simple transferoutput, *3 and work bit message *3 |
|
Ambient operating temperature |
-10 to 55°C (with no condensation or icing), For 3-year warranty: -10 to 50°C with standard mounting (with no condensation or icing) |
|
Ambient operating humidity | 25 to 85% | |
Storage temperature | -25 to 65°C (with no condensation or icing) | |
Altitude | 2,000 m max. | |
Recommended fuse | T2A, 250 VAC, time-lag, low-breaking capacity | |
Installation environment | Overvoltage category II, Pollution Degree 2 (EN/IEC/UL 61010-1) |
*1. This function is not supported by the E5DC-B. Refer to Model Number Legend.
*2. Only two set points are selectable for event inputs.
*3. Usage is possible for the Digital Temperature Controllers manufactured in July 2014 or later.
Analog input
Input type | Current | Voltage | |||
---|---|---|---|---|---|
Input specification | 4 to 20 mA | 0 to 20 mA | 1 to 5 V | 0 to 5 V | 0 to 10 V |
Setting range | Usable in the following ranges by scaling: -1999 to 9999, -199.9 to 999.9, -19.99 to 99.99 or -1.999 to 9.999 |
||||
Set value | 25 | 26 | 27 | 28 | 29 |
Characteristics
Indication accuracy (when mounted individually, ambient temperature of 23°C) |
Thermocouple: (±0.3 % of indication value or ±1°C, whichever is greater) ±1 digit max. *1 Platinum resistance thermometer: (±0.2 % of indication value or ±0.8°C, whichever is greater) ±1 digit max. Analog input: ±0.2% FS ±1 digit max. CT input: ±5% FS ±1 digit max. |
|
---|---|---|
Simple transfer output accuracy |
±0.3% FS max.*2 | |
Influence of temperature *3 |
Thermocouple input (R, S, B, C/W, PL II): (±1% of indication value or ±10°C, whichever is greater) ±1 digit max. Other thermocouple input: (±1% of indication value or ±4°C, whichever is greater) ±1 digit max. *4 Platinum resistance thermometer: (±1% of indication value or ±2°C, whichever is greater) ±1 digit max. Analog input: ±1% FS ±1 digit max. CT input: ±5% FS ±1 digit max. |
|
Influence of voltage *3 | ||
Influence of EMS. (at EN 61326-1) |
||
Installation influence (E5DC only) |
R, S, B, W, or PLII thermocouple: (±1% of PV or ±10°C, whichever is greater) ±1 digit max. Other thermocouple: (±1% of PV or ±4°C, whichever is greater) ±1 digit max. *4 |
|
Input sampling period | 50 ms | |
Hysteresis | Temperature input: 0.1 to 999.9°C or °F (in units of 0.1°C or °F) Analog input: 0.01% to 99.99% FS (in units of 0.01% FS) |
|
Proportional band (P) | Temperature input: 0.1 to 999.9°C or °F (in units of 0.1°C or °F) Analog input: 0.1% to 999.9% FS (in units of 0.1% FS) |
|
Integral time (I) | 0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *5 | |
Derivative time (D) | 0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *5 | |
Proportional band (P) for cooling |
Temperature input: 0.1 to 999.9°C or °F (in units of 0.1°C or °F) Analog input: 0.1% to 999.9% FS (in units of 0.1% FS) |
|
Integral time (I) for cooling |
0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *5 | |
Derivative time (D) for cooling |
0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *5 | |
Control period | 0.1, 0.2, 0.5, 1 to 99 s (in units of 1 s) | |
Manual reset value | 0.0% to 100.0% (in units of 0.1%) | |
Alarm setting range | -1,999 to 9,999 (decimal point position depends on input type) | |
Influence of signal source resistance |
Thermocouple: 0.1°C/Ω max. (100 Ω max.), Platinum resistance thermometer: 0.1°C/Ω max. (10 Ω max.) |
|
Insulation resistance | 20 MΩ min. (at 500 VDC) | |
Dielectric strength | 3,000 VAC, 50/60 Hz for 1 min between terminals of different charge | |
Vibration | Malfunction | 10 to 55 Hz, 20 m/s2 for 10 min each in X, Y and Z directions |
Resistance | 10 to 55 Hz, 20 m/s2 for 2 hr each in X, Y, and Z directions | |
Shock | Malfunction | 100 m/s2, 3 times each in X, Y, and Z directions |
Resistance | 300 m/s2, 3 times each in X, Y, and Z directions | |
Weight | Main unit: Approx. 80 g, Models with Screw Terminal Unit: Approx. 40 g, Models with Push-In Plus Terminal Unit: Approx. 40 g |
|
Degree of protection | Main unit: IP20, Terminal unit: IP00 | |
Memory protection | Non-volatile memory (number of writes: 1,000,000 times) | |
Setup Tool | CX-Thermo version 4.6 or higher | |
Setup Tool port | E5DC/E5DC-B bottom panel: An E58-CIFQ2 USB-Serial Conversion Cable is used to connect a USB port on the computer. *6 E5DC/E5DC-B front panel: An E58-CIFQ2 USB-Serial Conversion Cable and E58-CIFQ2-E Conversion Cable are used together to connect a USB port on the computer. *6 |
|
Standards | Approved standards |
cULus: UL 61010-1/CSA C22.2 No.61010-1, Korean wireless regulations (Radio law: KC Mark) (Some models only.) *7, Lloyd’s standards (E5DC only) *8 |
Conformed standards |
EN 61010-1 (IEC 61010-1), RCM | |
EMC | EMI: EN61326-1 *9 Radiated Interference Electromagnetic Field Strength: EN55011 Group 1, class A Noise Terminal Voltage: EN55011 Group 1, class A EMS: EN61326-1 *9 ESD Immunity: EN61000-4-2 Electromagnetic Field Immunity: EN61000-4-3 Burst Noise Immunity: EN61000-4-4 Conducted Disturbance Immunity: EN61000-4-6 Surge Immunity: EN61000-4-5 Voltage Dip/Interrupting Immunity: EN61000-4-11 |
*1. The indication accuracy of K thermocouples in the -200 to 1,300°C range, T and N thermocouples at a temperature of
−100°C max., and U and L thermocouples at any temperature is ±2°C ±1 digit max. The indication accuracy of B
thermocouples at a temperature of 400°C max. is not specified. The indication accuracy of B thermocouples at a
temperature of 400 to 800°C is ±3°C max.
The indication accuracy of R and S thermocouples at a temperature of 200°C max. is ±3°C ±1 digit max. The
indication accuracy of C/W thermocouples is (±0.3% of PV or ±3°C, whichever is greater) ±1 digit max.
The indication accuracy of PLII thermocouples is (±0.3% of PV or ±2°C, whichever is greater) ±1 digit max.
*2. However, the precision between 0 and 4 mA for a 0 to 20 mA output is ±1% FS max.
*3. Ambient temperature: −10°C to 23°C to 55°C, Voltage range: −15% to 10% of rated voltage
*4. K thermocouple at −100°C max.: ±10°C max.
*5. The unit is determined by the setting of the Integral/Derivative Time Unit parameter.
*6. External serial communications (RS-485) and USB-Serial Conversion Cable communications can be used at the
same time.
*7. Refer to your OMRON website for the most recent information on applicable models.
*8. Refer to information on maritime standards in Shipping Standards on Data Sheet for compliance with Lloyd’s
Standards.
*9. Industrial electromagnetic environment (EN/IEC 61326-1 Table 2)
Model | E5DC-RX2DSM-000 |
---|
Related products
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details