List of Models

Classification Configuration External
connections
Settings Display
digits
Outputs Power
supply
voltage
Model
Preset counter • 1-stage
preset counter
• Total and
preset counter
8-pin socket 1-stage 6 digits Contact output
(SPST)
100 to
240 VAC
H7CC-A8
24 VAC/
12 to 48
VDC
H7CC-A8D
11-pin socket Contact output
(SPDT)
100 to
240 VAC
H7CC-A11
Transistor output
(SPST)
H7CC-A11S
Contact output
(SPDT)
24 VAC/
12 to 48
VDC
H7CC-A11D
Transistor output
(SPST)
H7CC-A11SD
Screw
terminals
Contact output
(SPDT)
100 to
240 VAC
H7CC-A
Transistor output
(SPST)
H7CC-AS
Contact output
(SPDT)
24 VAC/
12 to 48
VDC
H7CC-AD
Transistor output
(SPST)
H7CC-ASD
Preset counter/
Tachometer
• 1-stage
preset counter
• 2-stage
preset counter
• Total and
preset counter
• Batch counter
• Dual counter
• Twin counter
• Tachometer
2-stage Contact output
(SPST+SPDT)
100 to
240 VAC
H7CC-AW
Transistor output
(DSPT)
H7CC-AWS
Contact output
(SPST+SPDT)
24 VAC/
12 to 48
VDC
H7CC-AWD
Transistor output
(DSPT)
H7CC-AWSD
Contact output
(SPDT)
+
Transistor output
(SPST)
100 to
240 VAC
H7CC-AU
24 VAC/
12 to 48
VDC
H7CC-AUD

 

 

Ratings

Item H7CC-A8/-A11[] H7CC-A[] H7CC-AW[]/AU[]
Classification Preset counter Preset counter/ tachometer
Configuration 1-stage preset counter, 1-stage preset counter with total counter (selectable) *1 1-stage/2-stage preset counter,
total and preset counter *1,
batch counter, dual counter,
twin counter, and tachometer
(selectable)
Ratings Power supply
voltage *2
• 100 to 240 VAC, 50/60 Hz
• 24 VAC, 50/60 Hz or 12 to 48 VDC
Operating
voltage
fluctuation
range
85% to 110% of rated supply voltage (12 to 48 VDC: 90% to 110%)
Power
consumption
Approx. 6.8 VA at 100 to 240 VAC,
Approx. 5.5 VA/3.3 W at 24 VAC/12 to 48 VDC,
Mounting method Flush mounting or surface mounting Flush mounting
External connections 8-pin/ 11-pin socket Screw terminals
Degree of protection IEC IP66 for panel surface only and only when Y92S-P6 Waterproof Packing is used.
Input signals CP1, CP2, reset, and total reset *4 CP1, CP2, reset 1, and reset 2
Counter Maximum
counting
speed
30 Hz (minimum pulse width: 16.7 ms) or 10 kHz (minimum pulse width: 0.05 ms) (selectable) (ON/OFF ratio 1:1)
*Common setting for CP1 and CP2
Input
mode
Increment (UP), decrement (DOWN), increment/decrement (UP/DOWN A (command input), UP/DOWN B (individual inputs), or UP/DOWN C (quadrature inputs)), UP/DOWN D (command input), UP/DOWN E (individual inputs), UP/DOWN E (quadrature inputs)
Output
mode
N, F, C, R, K-1, P, Q, A, K-2, D, and L. N, F, C, R, K-1, P, Q, A, K-2, D, L, and H.
One-shot
out put
time
0.01 to 99.99 s
Reset
system
External (minimum reset signal width: 1 ms or 20 ms, selectable), manual, and automatic reset (internal according to C, R, P, and Q mode operation)
Tachometer Refer to the tachometer function ratings.
Prescaling function Yes (0.001 to 99.999)
Decimal point adjustment Yes (right most 3 digits)
Sensor waiting time 290 ms max. (Control output is turned OFF and no input is accepted during sensor waiting time.)
Input method No-voltage (NPN) input/voltage (PNP) input (switchable)
No-voltage inputs:
ON impedance: 1 kΩ max. (Leakage current: 12 mA at 0 Ω) ON residual voltage: 3 V max.
OFF impedance: 100 kΩ min.
Voltage input:
High (logic) level: 4.5 to 30 VDC
Low (logic) level: 0 to 2 VDC (Input resistance: approx. 4.7 kΩ)
External power supply 12 VDC (±10%), 100 mA (except for H7CC-A8[] models) Refer to Precautions for Correct Use on Catalog for details.
Control output • Contact output: 3 A at 250 VAC/30 VDC, resistive load (cosφ=1),
Minimum applied load: 10 mA at 5 VDC (failure level: P, reference value)
• Transistor output: NPN open collector, 100 mA at 30 VDC, Residual voltage: 1.5 VDC max. (approx. 1 V),
Leakage current: 0.1 mA max.
Display *3 7-segment, negative transmissive LCD
Character height
Count value: 10 mm (white)
Set value: 6 mm (green)
Digits 6 digits
-99999 to 999999
(-5 digits to +6 digits)
6 digits
-99999 to 999999
(-5 digits to +6 digits),
tachometer: 0 to 999999
Memory backup Non-volatile memory (overwrites: 100,000 times min.) that can store data for 10 years min.
Operating temperature range -10 to 55°C (-10 to 50°C if Counter/Tachometers are mounted side by side) (with no icing or condensation)
Storage temperature range -25 to 70°C (with no icing or condensation)
Operating humidity range 25% to 85%
Case color Black (N1.5)
Attachments Flush mounting adapter, waterproof packing, terminal cover

 

*1. 1-stage preset counter and total counter functionality.
*2. Do not use the output from an inverter as the power supply.The ripple must be 20% maximum for DC power.
*3. The display is lit only when the power is ON. Nothing is displayed when power is OFF.
*4. Only reset input is performed in the H7CC-A8[], and the total count is also reset simultaneously.

 

Tachometer Function Ratings

Item H7CC-A8[] H7CC-A11[] H7CC-A[] H7CC-AW[]/AU[]
Input mode No
tachometer
functionality
Selectable from 1 inputs, independent measurements for 2 inputs,
differential input for 2 inputs, absolute ratio for 2 inputs,
and error ratio for 2 inputs.
Pulse measurement
method
Periodic measurement Pulse width measurement
Maximum counting
speed
30 Hz
(minimum pulse width: 16.7 ms)
1-input mode:
10 kHz (minimum pulse width: 0.05 ms)
Other modes:
5 kHz (minimum pulse width: 0.1 ms)
30 Hz
(minimum pulse width: 16.7 ms)
1-input mode:
10 kHz (minimum pulse width: 0.05 ms)
Other modes:
5 kHz (minimum pulse width: 0.1 ms)
Minimum input
signal width
30 ms * 1-input mode: 0.2 ms
Other modes: 0.4 ms*
Measuring ranges 0.001 to 30.00 Hz 1-input mode: 0.001 to 10 kHz,
Other modes: 0.01 to 5 kHz
0.030 to 999999 s 1-input mode: 0.0002 to 999999 s
Other modes: 0.0004 to 999999 s
Sampling period 200 ms min. 200 ms min. or continuous
selectable (minimum interval of 10 ms)
Continuous (minimum interval of 10 ms)
Measuring accuracy ±0.1% FS ±1 digit max. (at 23 ±5°C)
Output mode Input mode:
Not 2-input independent measurement: HI-LO, AREA, HI-HI, LO-LO
2-input independent measurement: HI-HI, LO-LO
Auto-zero time 0.1 to 999.9s
Startup time 0.0 to 99.9s
Averaging Simple averaging/moving averaging selectable, Processing: OFF, 2, 4, 8, or 16 times
Hold input Minimum input signal width: 20 ms

 

* An input OFF time of at least 20 ms is required.

 

Characteristics

Insulation resistance 100 MΩ min. (at 500 VDC) between current-carrying terminals and exposed non-current-carrying metal parts, and between non-continuous contacts
Dielectric strength 2,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and non-current-carrying metal parts
2,000 VAC, 50/60 Hz for 1 min between power supply and input circuit for all models except H7CC-[]D[] (1,500 VAC for 24 VAC/12 to 48 VDC)
1,500 VAC (for H7CC-[]SD[]), 50/60 Hz for 1 min between control output, power supply, and input circuit
(2,000 VACfor models other than H7CC-[]SD[])
1,000 VAC, 50/60 Hz for 1 min between non-continuous contacts
Impulse withstand voltage 6.0 kV between power terminals (1.0 kV for models with 24 VAC/12 to 48 VDC)
6.0 kV between current-carrying terminals and exposed non-current-carrying metal parts
(1.5 kV for models with 24 VAC/12 to 48 VDC)
Static immunity Malfunction: 8 kV
Destruction: 15 kV
Vibration
resistance
Destruction 10 to 55 Hz with 0.75-mm single amplitude each in three directions for 2 h each
Malfunction 10 to 55 Hz with 0.35-mm single amplitude each in three directions for 10 min each
Shock
resistance
Destruction 300 m/s2 each in three directions
Malfunction 100 m/s2 each in three directions
Life expectancy Mechanical: 10,000,000 operations min.
Electrical: 100,000 operations min. (3 A at 250 VAC, resistive load, ambient temperature condition: 23°C) *
Weight Approx. 120 g (Counter only)

 