SICK 1067982 GRSE18-P1147 M18 PNP Through-beam Sensor Set

SICK 1067982 GRSE18-P1147 M18 PNP Through-beam Sensor Set

USD 79.82

GRSE18-P1147 offers 0–10 m through-beam sensing, 650 nm red light, complementary PNP outputs, sensitivity adjustment, sender test input and 2 m PVC cables.

SKU: SICK-1067982 Category:
SICK GR18

SICK GRSE18-P1147 M18 PNP Through-beam Sensor Set

BrandSICK
Model IdentifierGRSE18-P1147
Official Part Number1067982

Technical Overview

The SICK GRSE18-P1147 is an M18 ×1 through-beam photoelectric sensor set with separate GRS18-D1346 sender and GRE18-P1137 receiver. Axial 650 nm red PinPoint optics provide 0–10 m sensing and 0–15 m maximum range, with a 250 mm spot at 10 m. A 270° potentiometer adjusts sensitivity and complementary PNP outputs provide light and dark signals. The sender can be switched off by applying 0 V to Test. Response is below 500 µs with resistive load, with 1,000 Hz switching at a 1:1 light/dark ratio. The 10–30 V DC devices use ABS housings, PMMA optics, IP67 protection and 2 m four-wire PVC cables. Four plastic fastening nuts support mounting.

Axial M18 through-beam set with 0–10 m sensing, complementary PNP outputs, 270° sensitivity adjustment, sender test input and 2 m four-wire PVC cables.

Key Features

  • Separate GRS18-D1346 sender and GRE18-P1137 receiver
  • 0–10 m sensing; 0–15 m maximum range
  • Axial M18 ×1 optics; 650 nm red PinPoint LED; Ø250 mm spot at 10 m
  • 270° sensitivity potentiometer
  • Complementary PNP light/dark outputs
  • Sender-off test input: Test at 0 V
  • <500 µs response with resistive load; 1,000 Hz at 1:1 light/dark ratio
  • 10–30 V DC; ≤100 mA output, reduced to 50 mA above 24 V or +49 °C ambient
  • 2 m four-wire PVC cables; do not bend below 0 °C
  • ABS housings; PMMA optics; IP67; four plastic fastening nuts supplied

Detect interruptions between opposed M18 sender and receiver units, with complementary PNP signals and a sender-off test input available to external process logic.

Technical Specification Matrix

ParameterValue
Functional principleThrough-beam photoelectric sensor set with separate sender and receiver
Individual componentsGRS18-D1346 sender, part 2072233; GRE18-P1137 receiver, part 2073763
Housing designCylindrical M18 ×1; axial optical axis
Sensing range0–10 m
Maximum sensing range0–15 m
Light sourceVisible red PinPoint LED
Wavelength650 nm
Light spot sizeØ250 mm at 10 m
LED service lifeAverage 100,000 h at ambient +25 °C
AdjustmentSensitivity potentiometer, 270°
Switching outputComplementary PNP outputs
Switching modeLight/dark switching through complementary outputs
Signal voltage HIGH/LOWSupply voltage −(≤3 V) / approximately 0 V
Output current≤100 mA; maximum 50 mA at supply voltage >24 V or ambient temperature >49 °C
Response time<500 µs with resistive load
Switching frequency1,000 Hz at 1:1 light/dark ratio
Power supply10–30 V DC; limit values in a short-circuit-protected network, maximum 8 A
Ripple<5 Vpp; remain within supply tolerances
Current consumption30 mA
Connection2 m four-wire PVC cables; do not bend below 0 °C
Wire assignmentsCD-088: sender BN=L+, BU=M, BK=Test, WH=not connected; receiver BN=L+, BU=M, BK=Q, WH=Q̅
Test inputSender off at Test=0 V
Circuit protectionA: supply reverse-polarity protection; B: inputs and output reverse-polarity protection; D: outputs overcurrent and short-circuit protection
Protection classIII
Housing materialABS plastic
Optics materialPMMA plastic
IP ratingIP67
Items suppliedFour plastic fastening nuts; 22 mm across flats
EMCEN 60947-5-2
Operating temperature−25 to +55 °C at supply voltage ≤24 V and output current <50 mA
Storage temperature−40 to +70 °C
UL fileE348498
IndicatorsGreen steady on: power on; yellow steady on: object absent; yellow off: object present

Industrial Applications

1. Counting separated cartons across a conveyor

A conveyor can position the sender and receiver on opposite sides of a load path so separated opaque cartons interrupt the direct red beam. External counting logic evaluates a complementary PNP signal. Setup adjusts sensitivity and aligns the opposed units, then checks carton coverage, load spacing and transit speed against the sensing range, response time and switching-frequency conditions.

Problem Solved

A beam-interruption event gives an external counter a carton-passage reference, using opposed optics that do not require reflected light from the passing carton surface.

Carton counting Through-beam optics Complementary PNP

2. Monitoring opaque material continuity

An opaque feed strip can cross the beam between sender and receiver and block light while material occupies the sensing point. A break or runout changes the receiver condition for external feed monitoring. Commissioning aligns both axial optical faces, adjusts sensitivity and checks strip coverage and lateral movement so the normal feed remains distinguishable from a clear optical path.

Problem Solved

A changed received-light condition helps external feed monitoring identify a break or runout at the checked location, using direct-beam interruption across the actual material path.

Feed continuity Direct beam PNP interface

3. Checking a transfer beam through its sender test input

A transfer station can use the beam for normal opaque-carrier monitoring and request a controlled sender-off check when the process permits it. External maintenance logic applies 0 V to Test and observes the receiver’s complementary PNP signals. Commissioning establishes the expected clear and interrupted states, using the documented wiring and actual optical alignment before enabling the check.

Problem Solved

A controlled sender-off condition gives external maintenance logic a repeatable optical interruption for comparing expected receiver states, helping troubleshoot the transfer beam and its connected process inputs.

Sender-off test Transfer diagnostics Complementary outputs