product name |
3RT2024-1AG24 |
product brand name |
SIRIUS |
product designation |
Power contactor |
product type designation |
3RT2 |
General technical data |
|
size of contactor |
S0 |
product extension |
No |
● function module for communication |
● auxiliary switch |
No |
power loss [W] for rated value of the current |
0.9 W |
● at AC in hot operating state |
● at AC in hot operating state per pole |
0.3 W |
● without load current share typical |
7.9 W |
insulation voltage |
690 V |
● of main circuit with degree of pollution 3 rated value |
● of auxiliary circuit with degree of pollution 3 rated value |
690 V |
surge voltage resistance |
6 kV |
● of main circuit rated value |
● of auxiliary circuit rated value |
6 kV |
maximum permissible voltage for safe isolation between coil and main contacts according to EN 60947-1 |
400 V |
shock resistance at rectangular impulse |
7,5g / 5 ms, 4,7g / 10 ms |
● at AC |
shock resistance with sine pulse |
11,8g / 5 ms, 7,4g / 10 ms |
● at AC |
mechanical service life (operating cycles) |
10 000 000 |
● of contactor typical |
● of the contactor with added electronically optimized auxiliary switch block typical |
5 000 000 |
● of the contactor with added auxiliary switch block typical |
10 000 000 |
reference code according to IEC 81346-2 |
Q |
Substance Prohibitance (Date) |
10/1/2009 |
Ambient conditions |
|
installation altitude at height above sea level maximum |
2 000 m |
ambient temperature |
-25 … +60 °C |
● during operation |
● during storage |
-55 … +80 °C |
relative humidity minimum |
10% |
relative humidity at 55 °C according to IEC 60068-2-30 maximum |
95% |
Main circuit |
|
number of poles for main current circuit |
3 |
number of NO contacts for main contacts |
3 |
operating voltage |
|
? at AC-3 rated value maximum |
690 V |
? at AC-3e rated value maximum |
690 V |
operational current |
|
? at AC-1 at 400 V at ambient temperature 40 °C rated value |
40 A |
? at AC-1 |
|
— up to 690 V at ambient temperature 40 °C rated value |
40 A |
— up to 690 V at ambient temperature 60 °C rated value |
35 A |
? at AC-3 |
|
— at 400 V rated value |
12A |
— at 500 V rated value |
12A |
— at 690 V rated value |
9A |
? at AC-3e |
|
— at 400 V rated value |
12A |
— at 500 V rated value 12A |
12A |
— at 690 V rated value 9A |
9A |
? at AC-4 at 400 V rated value |
12.5 A |
? at AC-5a up to 690 V rated value x |
12.5 A |
? at AC-5b up to 400 V rated value |
9.9 A |
? at AC-6a |
|
— up to 230 V for current peak value n=20 rated value |
11.4 A |
— up to 400 V for current peak value n=20 rated value |
11.4 A |
— up to 500 V for current peak value n=20 rated value |
11.3 A |
— up to 690 V for current peak value n=20 rated value |
9A |
? at AC-6a |
2.9 A |
— up to 230 V for current peak value n=30 rated value |
7.6 A |
— up to 400 V for current peak value n=30 rated value |
7.6 A |
— up to 500 V for current peak value n=30 rated value |
7.6 A |
— up to 690 V for current peak value n=30 rated value |
7.6 A |
minimum cross-section in main circuit at maximum AC-1 rated value |
10 mm² |
operational current for approx. 200000 operating |
|
cycles at AC-4 |
|
? at 400 V rated value |
5.5 A |
? at 690 V rated value |
5.5 A |
operational current |
|
? at 1 current path at DC-1 |
|
— at 24 V rated value |
35 A |
— at 110 V rated value |
4.5 A |
— at 220 V rated value |
1A |
— at 440 V rated value |
0.4 A |
— at 600 V rated value |
0.25 A |
? with 2 current paths in series at DC-1 |
|
— at 24 V rated value |
35 A |
— at 110 V rated value |
35 A |
— at 220 V rated value |
5A |
— at 440 V rated value |
1A |
— at 600 V rated value |
0.8 A |
? with 3 current paths in series at DC-1 |
|
— at 24 V rated value |
35 A |
— at 110 V rated value |
35 A |
— at 220 V rated value |
35 A |
— at 440 V rated value |
2.9 A |
— at 600 V rated value |
1.4 A |
? at 1 current path at DC-3 at DC-5 |
|
— at 24 V rated value |
20 A |
— at 220 V rated value |
1A |
— at 440 V rated value |
0.09 A |
— at 600 V rated value |
0.06 A |
? with 2 current paths in series at DC-3 at DC-5 |
|
— at 24 V rated value |
35 A |
— at 110 V rated value |
15 A |
— at 220 V rated value |
3A |
— at 440 V rated value |
0.27 A |
— at 600 V rated value |
0.16 A |
? with 3 current paths in series at DC-3 at DC-5 |
|
— at 24 V rated value |
35 A |
— at 110 V rated value |
35 A |
— at 220 V rated value |
10A |
— at 440 V rated value |
0.6 A |
— at 600 V rated value |
0.6 A |
operating power |
|
? at AC-3 |
|
— at 230 V rated value |
3 kW |
— at 400 V rated value |
5.5 kW |
— at 500 V rated value 5.5 kW |
5.5 kW |
— at 690 V rated value |
7.5 kW |
? at AC-3e |
|
— at 230 V rated value |
3 kW |
— at 400 V rated value |
5.5 kW |
— at 500 V rated value |
5.5 kW |
— at 690 V rated value |
7.5 kW |
operating power for approx. 200000 operating cycles at AC-4 |
|
? at 400 V rated value |
2.6 kW |
? at 690 V rated value |
4.6 kW |
operating apparent power at AC-6a |
|
? up to 230 V for current peak value n=20 rated value |
4.5 kVA |
? up to 400 V for current peak value n=20 rated value |
7.8 kVA |
? up to 500 V for current peak value n=20 rated value |
9.8 kVA |
? up to 690 V for current peak value n=20 rated value |
10.7 kVA |
operating apparent power at AC-6a |
|
? up to 230 V for current peak value n=30 rated value |
3 kVA |
? up to 400 V for current peak value n=30 rated value |
5.2 kVA |
? up to 500 V for current peak value n=30 rated value |
6.5 kVA |
? up to 690 V for current peak value n=30 rated value |
9 kVA |
short-time withstand current in cold operating state |
|
up to 40 °C |
|
? limited to 1 s switching at zero current maximum |
210 A; Use minimum cross-section acc. to AC-1 rated value |
? limited to 5 s switching at zero current maximum |
210 A; Use minimum cross-section acc. to AC-1 rated value |
? limited to 10 s switching at zero current maximum |
170 A; Use minimum cross-section acc. to AC-1 rated value |
? limited to 30 s switching at zero current maximum |
126 A; Use minimum cross-section acc. to AC-1 rated value |
? limited to 60 s switching at zero current maximum |
105 A; Use minimum cross-section acc. to AC-1 rated value |
no-load switching frequency |
|
? at AC |
5 000 1/h |
operating frequency |
|
? at AC-1 maximum |
1 000 1/h |
? at AC-2 maximum |
1 000 1/h |
? at AC-3 maximum |
1 000 1/h |
? at AC-3e maximum |
1 000 1/h |
? at AC-4 maximum |
300 1/h |
Control circuit/ Control |
|
type of voltage of the control supply voltage |
AC |
control supply voltage at AC |
|
? at 50 Hz rated value |
110 V |
? at 60 Hz rated value |
110 V |
operating range factor control supply voltage rated |
|
value of magnet coil at AC |
|
? at 50 Hz |
0.8 … 1.1 |
? at 60 Hz |
0.85 … 1.1 |
apparent pick-up power of magnet coil at AC |
|
? at 50 Hz |
68 VA |
? at 60 Hz |
67 VA |
inductive power factor with closing power of the coil |
|
? at 50 Hz |
0.72 |
? at 60 Hz |
0.74 |
apparent holding power of magnet coil at AC |
|
? at 50 Hz |
7.9 VA |
? at 60 Hz |
6.5 VA |
inductive power factor with the holding power of the coil |
|
? at 50 Hz |
0.25 |
? at 60 Hz |
0.28 |
closing delay |
|
? at AC |
8 … 40 ms |
opening delay |
|
? at AC |
4 … 16 ms |
arcing time |
10 … 10 ms |
control version of the switch operating mechanism |
Standard A1 – A2 |
Auxiliary circuit |
|
number of NC contacts for auxiliary contacts instantaneous contact |
2 |
number of NO contacts for auxiliary contacts instantaneous contact |
2 |
operational current at AC-12 maximum |
10:00 AM |
operational current at AC-15 |
6:00 AM |
● at 230 V rated value |
● at 400 V rated value |
3:00 AM |
● at 500 V rated value |
2:00 AM |
● at 690 V rated value |
1:00 AM |
operational current at DC-12 |
10:00 AM |
● at 24 V rated value |
● at 48 V rated value |
6:00 AM |
● at 60 V rated value |
6:00 AM |
● at 110 V rated value |
3:00 AM |
● at 125 V rated value |
2:00 AM |
● at 220 V rated value |
1:00 AM |
● at 600 V rated value |
0.15 A |
operational current at DC-13 |
6:00 AM |
● at 24 V rated value |
● at 48 V rated value |
2:00 AM |
● at 60 V rated value |
2:00 AM |
● at 110 V rated value |
1:00 AM |
● at 125 V rated value |
0.9 A |
● at 220 V rated value |
0.3 A |
● at 600 V rated value |
0.1 A |
contact reliability of auxiliary contacts |
1 faulty switching per 100 million (17 V, 1 mA) |
UL/CSA ratings |
|
full-load current (FLA) for 3-phase AC motor |
11:00 AM |
● at 480 V rated value |
● at 600 V rated value |
11:00 AM |
yielded mechanical performance [hp] ● for single-phase AC motor |
1 hp |
— at 110/120 V rated value |
— at 230 V rated value |
2 hp |
● for 3-phase AC motor |
3 hp |
— at 200/208 V rated value |
— at 220/230 V rated value |
3 hp |
— at 460/480 V rated value |
7.5 hp |
— at 575/600 V rated value |
10 hp |
contact rating of auxiliary contacts according to UL |
A600 / Q600 |
Short-circuit protection |
|
design of the fuse link |
gG: 63A (690V,100kA), aM: 32A (690V,100kA), BS88: 63A (415V,80kA) |
● for short-circuit protection of the main circuit |
— with type of coordination 1 required |
— with type of assignment 2 required |
gG: 25A (690V,100kA), aM: 20A (690V,100kA), BS88: 25A (415V,80kA) |
● for short-circuit protection of the auxiliary switch required |
gG: 10 A (500 V, 1 kA) |
Installation/ mounting/ dimensions |
|
mounting position |
+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface |
fastening method |
screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715 |
● side-by-side mounting |
Yes |
height |
85 mm |
width |
45 mm |
depth |
141 mm |
required spacing |
10 mm |
● with side-by-side mounting |
— forwards |
— upwards |
10 mm |
— downwards |
10 mm |
— at the side |
0 mm |
● for grounded parts |
10 mm |
— forwards |
— upwards |
10 mm |
— at the side |
6 mm |
— downwards |
10 mm |
● for live parts — forwards |
10 mm |
— upwards |
10 mm |
— downwards |
10 mm |
— at the side |
6 mm |
Connections/ Terminals |
|
type of electrical connection |
screw-type terminals |
● for main current circuit |
● for auxiliary and control circuit |
screw-type terminals |
● at contactor for auxiliary contacts |
Screw-type terminals |
● of magnet coil |
Screw-type terminals |
type of connectable conductor cross-sections ● for main contacts |
2x (1 … 2.5 mm²), 2x (2.5 … 10 mm²) |
— solid |
— solid or stranded |
2x (1 … 2.5 mm²), 2x (2.5 … 10 mm²) |
— finely stranded with core end processing |
2x (1 … 2.5 mm²), 2x (2.5 … 6 mm²), 1x 10 mm² |
● at AWG cables for main contacts |
2x (16 … 12), 2x (14 … 8) |
connectable conductor cross-section for main contacts |
1 … 10 mm² |
● solid |
● stranded |
1 … 10 mm² |
● finely stranded with core end processing |
1 … 10 mm² |
connectable conductor cross-section for auxiliary contacts |
0.5 … 2.5 mm² |
● solid or stranded |
● finely stranded with core end processing |
0.5 … 2.5 mm² |
type of connectable conductor cross-sections ● for auxiliary contacts |
2x (0.5 … 1.5 mm²), 2x (0.75 … 2.5 mm²) |
— solid or stranded |
— finely stranded with core end processing |
2x (0.5 … 1.5 mm²), 2x (0.75 … 2.5 mm²) |
● at AWG cables for auxiliary contacts |
2x (20 … 16), 2x (18 … 14) |
AWG number as coded connectable conductor cross section |
16 … 8 |
● for main contacts |
● for auxiliary contacts |
20 … 14 |
Safety related data |
product function |
|
● mirror contact according to IEC 60947-4-1 |
Yes No |
● positively driven operation according to IEC 60947-5-1 |
450 000 |
B10 value with high demand rate according to SN 31920 proportion of dangerous failures |
40% |
● with low demand rate according to SN 31920 |
73% |
● with high demand rate according to SN 31920failure rate [FIT] with low demand rate according to SN 31920 |
100 FIT |
T1 value for proof test interval or service life according to IEC 61508 protection class IP on the front according to IEC |
20 a IP20 |
60529 touch protection on the front according to IEC 60529 suitability for use |
finger-safe, for vertical contact from the front |
● safety-related switching OFF |
Yes |