$ 286.88
The IM 157-1 PN interface module enables the connection of ET 200AL to PROFINET and handles the communication between the I/O modules and the higher-level PROFINET I/O controller in the PLC autonomously.
Article number | 6ES7157-1AB00-0AB0 | |
ET 200AL, IM 157-1 PN | ||
General information | ||
Product type designation | IM 157-1 PN | |
HW functional status | FS02 | |
Firmware version | V1.0.x | |
Vendor identification (VendorID) | 002AH | |
Product function | ||
● I&M data | Yes; I&M0 to I&M4 | |
Engineering with | ||
● STEP 7 TIA Portal configurable/integrated from version | STEP 7 V13 SP1 or higher | |
● STEP 7 configurable/integrated from version | From V5.5 SP4 Hotfix 3 | |
● PROFINET from GSD version/GSD revision | GSDML V2.3.1 | |
Configuration control | ||
via dataset | Yes | |
Supply voltage | ||
power supply according to NEC Class 2 required | No | |
Load voltage 1L+ | ||
● Rated value (DC) | 24 V | |
● permissible range, lower limit (DC) | 20.4 V | |
● permissible range, upper limit (DC) | 28.8 V | |
● Reverse polarity protection | Yes; against destruction | |
Input current | ||
Current consumption (rated value) | 100 mA | |
from load voltage 1L+ (unswitched voltage) | 4 A; Maximum value | |
from load voltage 2L+, max. | 4 A; Maximum value | |
Power loss | ||
Power loss, typ. | 2.9 W | |
Address area | ||
Address space per station | ||
● Address space per station, max. | 1 430 byte | |
Interfaces | ||
Number of PROFINET interfaces | 1 | |
1. Interface | ||
Interface type | PROFINET | |
Interface types | ||
● M12 port | Yes; 2x M12 D-coded | |
● integrated switch | Yes | |
Protocols | ||
● PROFINET IO Device | Yes | |
● Open IE communication | Yes | |
Interface types | ||
M12 port | ||
● Transmission procedure | PROFINET with 100 Mbit/s full duplex (100BASE-TX) | |
● 10 Mbps | Yes; for Ethernet services | |
● 100 Mbps | Yes; PROFINET with 100 Mbit/s full duplex (100BASE-TX) | |
● Autonegotiation | Yes | |
● Autocrossing | Yes | |
Protocols | ||
PROFINET IO Device | ||
Services | ||
— IRT | Yes; 250 µs, 500 µs, 1 ms, 2 ms, 4 ms, 8 ms, 16 ms, 32 ms, 64 ms, 128 ms | |
— PROFIenergy | Yes | |
— Shared device | Yes | |
— Number of IO Controllers with shared device, max. | 4 | |
Redundancy mode | ||
Media redundancy | ||
— MRP | Yes | |
— MRPD | Yes | |
Open IE communication | ||
● TCP/IP | Yes | |
● SNMP | Yes | |
● LLDP | Yes | |
Interrupts/diagnostics/status information | ||
Diagnostics function | Yes | |
Alarms | ||
● Diagnostic alarm | Yes | |
Diagnostics indication LED | ||
● RUN LED | Yes; green LED | |
● ERROR LED | Yes; red LED | |
● MAINT LED | Yes; Yellow LED | |
● Connection display LINK TX/RX | Yes; 2x green LED | |
Potential separation | ||
between the load voltages | Yes | |
between PROFINET and all other circuits | Yes | |
Isolation | ||
Isolation tested with | 707 V DC (type test) | |
Degree and class of protection | ||
IP degree of protection | IP65/67 | |
Standards, approvals, certificates | ||
Suitable for safety-related tripping of standard modules | Yes; From FS01 | |
Highest safety class achievable for safety-related tripping of standard modules | ||
● Performance level according to ISO 13849-1 | PL d | |
● Category according to ISO 13849-1 | Cat. 3 | |
● SIL acc. to IEC 62061 | SIL 2 | |
Ambient conditions | ||
Ambient temperature during operation | ||
● min. | -25 °C | |
● max. | 55 °C | |
connection method / header | ||
Design of electrical connection for supply voltage | M8, 4-pole | |
ET-Connection | ||
● ET-Connection | M8, 4-pin, shielded | |
Dimensions | ||
Width | 45 mm | |
Height | 159 mm | |
Depth | 40 mm | |
Weights | ||
Weight, approx. | 263 g |
Weight | 0.3 kg |
---|---|
Dimensions | 5.5 × 17.6 × 5.2 cm |
INOSAKI Limited
RM B 5/F Gaylord Comm,
Bldg 114-118 Lockhart Rd.
Hong Kong
INOSAKI Sdn. Bhd.
2-1-9, Ground Floor, One Square, Tingkat Mahsuri 1,
11900 Bayan Lepas, Penan
INOSAKI Pte. Ltd.
101 Upper Cross Street,
No. 06-17, People’s Park Centre,
Singapore (058357)