Analog input modules record process signals such as pressure or temperature and forward them in digitalized format (16-bit format) to the PLC. They are suitable for measuring current (2-wire and 4-wire transducers), voltage, and resistance, as well as for the connection of resistance thermometers and thermocouples (measurement types depend on the module).
The following analog input modules are available:
Article number | 6ES7531-7QD00-0AB0 | 6ES7531-7KF00-0AB0 | 6ES7531-7NF10-0AB0 | 6ES7531-7NF00-0AB0 | |
S7-1500, AI 4xU/I/RTD/TC ST | S7-1500, AI 8xU/I/RTD/TC ST | S7-1500, AI 8xU/I HS | S7-1500, AI 8xU/I HF | ||
General information | |||||
Product type designation | AI 4xU/I/RTD/TC ST | AI 8xU/I/RTD/TC ST | AI 8xU/I HS | AI 8xU/I HF | |
HW functional status | From FS01 | FS04 | From FS01 | From FS01 | |
Firmware version | V1.0.0 | V2.0.0 | V2.1.0 | V1.1.0 | |
● FW update possible | Yes | Yes | Yes | Yes | |
Product function | |||||
● I&M data | Yes; I&M0 to I&M3 | Yes; I&M0 to I&M3 | Yes; I&M0 to I&M3 | Yes; I&M0 to I&M3 | |
● Isochronous mode | No | No | Yes | No | |
● Prioritized startup | No | No | Yes | Yes | |
● Measuring range scalable | No | No | No | No | |
● Scalable measured values | No | No | No | Yes | |
● Adjustment of measuring range | No | No | No | Yes | |
Engineering with | |||||
● STEP 7 TIA Portal configurable/integrated from version | V13 / V13.0.2 | V12 / V12 | V14 / – | V14 / – | |
● STEP 7 configurable/integrated from version | V5.5 SP3 / – | V5.5 SP3 / – | V5.5 SP3 / – | V5.5 SP3 / – | |
● PROFIBUS from GSD version/GSD revision | V1.0 / V5.1 | V1.0 / V5.1 | V1.0 / V5.1 | V1.0 / V5.1 | |
● PROFINET from GSD version/GSD revision | V2.3 / – | V2.3 / – | V2.3 / – | V2.3 / – | |
Operating mode | |||||
● Oversampling | No | No | Yes | No | |
● MSI | Yes | Yes | Yes | Yes | |
CiR – Configuration in RUN | |||||
Reparameterization possible in RUN | Yes | Yes | Yes | Yes | |
Calibration possible in RUN | Yes | Yes | Yes | Yes | |
Supply voltage | |||||
Rated value (DC) | 24 V | 24 V | 24 V | 24 V | |
permissible range, lower limit (DC) | 19.2 V | 19.2 V | 19.2 V | 19.2 V | |
permissible range, upper limit (DC) | 28.8 V | 28.8 V | 28.8 V | 28.8 V | |
Reverse polarity protection | Yes | Yes | Yes | Yes | |
Input current | |||||
Current consumption, max. | 165 mA | 240 mA; with 24 V DC supply | 240 mA; with 24 V DC supply | 50 mA; with 24 V DC supply | |
Encoder supply | |||||
24 V encoder supply | |||||
● Short-circuit protection | Yes | Yes | Yes | ||
● Output current, max. | 20 mA; Max. 47 mA per channel for a duration < 10 s | 20 mA; Max. 47 mA per channel for a duration < 10 s | 20 mA; Max. 47 mA per channel for a duration < 10 s | ||
Power | |||||
Power available from the backplane bus | 0.7 W | 0.7 W | 1.15 W | 0.85 W | |
Power loss | |||||
Power loss, typ. | 2.3 W | 2.7 W | 3.4 W | 1.9 W | |
Analog inputs | |||||
Number of analog inputs | 4 | 8 | 8 | 8 | |
● For current measurement | 4 | 8 | 8 | 8 | |
● For voltage measurement | 4 | 8 | 8 | 8 | |
● For resistance/resistance thermometer measurement | 2 | 4 | |||
● For thermocouple measurement | 4 | 8 | |||
permissible input voltage for voltage input (destruction limit), max. | 28.8 V | 28.8 V | 28.8 V | 28.8 V | |
permissible input current for current input (destruction limit), max. | 40 mA | 40 mA | 40 mA | 40 mA | |
Constant measurement current for resistance-type transmitter, typ. | 150 Ohm, 300 Ohm, 600 Ohm, Pt100, Pt200, Ni100: 1.25 mA; 6 000 Ohm, Pt500, Pt1000, Ni1000, LG-Ni1000: 0.625 mA; PTC: 0.472 mA | 150 Ohm, 300 Ohm, 600 Ohm, Pt100, Pt200, Ni100: 1.25 mA; 6 000 Ohm, Pt500, Pt1000, Ni1000, LG-Ni1000: 0.625 mA; PTC: 0.472 mA | |||
Technical unit for temperature measurement adjustable | Yes; °C/°F/K | Yes; °C/°F/K | |||
Analog input with oversampling | No | ||||
Standardization of measured values | No | ||||
Input ranges (rated values), voltages | |||||
● 0 to +5 V | No | No | No | No | |
● 0 to +10 V | No | No | No | No | |
● 1 V to 5 V | Yes | Yes | Yes | Yes | |
— Input resistance (1 V to 5 V) | 100 kΩ | 100 kΩ | 50 kΩ | 100 kΩ | |
● -1 V to +1 V | Yes | Yes | |||
— Input resistance (-1 V to +1 V) | 10 MΩ | 10 MΩ | |||
● -10 V to +10 V | Yes | Yes | Yes | Yes | |
— Input resistance (-10 V to +10 V) | 100 kΩ | 100 kΩ | 100 kΩ | 100 kΩ | |
● -2.5 V to +2.5 V | Yes | Yes | No | Yes | |
— Input resistance (-2.5 V to +2.5 V) | 10 MΩ | 10 MΩ | 100 kΩ | ||
● -25 mV to +25 mV | No | No | No | No | |
● -250 mV to +250 mV | Yes | Yes | No | No | |
— Input resistance (-250 mV to +250 mV) | 10 MΩ | 10 MΩ | |||
● -5 V to +5 V | Yes | Yes | Yes | Yes | |
— Input resistance (-5 V to +5 V) | 100 kΩ | 100 kΩ | 50 kΩ | 100 kΩ | |
● -50 mV to +50 mV | Yes | Yes | No | No | |
— Input resistance (-50 mV to +50 mV) | 10 MΩ | 10 MΩ | |||
● -500 mV to +500 mV | Yes | Yes | No | No | |
— Input resistance (-500 mV to +500 mV) | 10 MΩ | 10 MΩ | |||
● -80 mV to +80 mV | Yes | Yes | No | No | |
— Input resistance (-80 mV to +80 mV) | 10 MΩ | 10 MΩ | |||
Input ranges (rated values), currents | |||||
● 0 to 20 mA | Yes | Yes | Yes | Yes | |
— Input resistance (0 to 20 mA) | 25 Ω; Plus approx. 42 ohms for overvoltage protection by PTC | 25 Ω; Plus approx. 42 ohms for overvoltage protection by PTC | 41 Ω; Plus approx. 42 ohms for overvoltage protection by PTC | 25 Ω; Plus approx. 42 ohms for overvoltage protection by PTC | |
● -20 mA to +20 mA | Yes | Yes | Yes | Yes | |
— Input resistance (-20 mA to +20 mA) | 25 Ω; Plus approx. 42 ohms for overvoltage protection by PTC | 25 Ω; Plus approx. 42 ohms for overvoltage protection by PTC | 41 Ω; Plus approx. 42 ohms for overvoltage protection by PTC | 25 Ω; Plus approx. 42 ohms for overvoltage protection by PTC | |
● 4 mA to 20 mA | Yes | Yes | Yes | Yes | |
— Input resistance (4 mA to 20 mA) | 25 Ω; Plus approx. 42 ohms for overvoltage protection by PTC | 25 Ω; Plus approx. 42 ohms for overvoltage protection by PTC | 41 Ω; Plus approx. 42 ohms for overvoltage protection by PTC | 25 Ω; Plus approx. 42 ohms for overvoltage protection by PTC | |
Input ranges (rated values), thermocouples | |||||
● Type B | Yes | Yes | No | No | |
— Input resistance (Type B) | 10 MΩ | 10 MΩ | |||
● Type C | No | No | No | No | |
● Type E | Yes | Yes | No | No | |
— Input resistance (Type E) | 10 MΩ | 10 MΩ | |||
● Type J | Yes | Yes | No | No | |
— Input resistance (type J) | 10 MΩ | 10 MΩ | |||
● Type K | Yes | Yes | No | No | |
— Input resistance (Type K) | 10 MΩ | 10 MΩ | |||
● Type L | No | No | No | No | |
● Type N | Yes | Yes | No | No | |
— Input resistance (Type N) | 10 MΩ | 10 MΩ | |||
● Type R | Yes | Yes | No | No | |
— Input resistance (Type R) | 10 MΩ | 10 MΩ | |||
● Type S | Yes | Yes | No | No | |
— Input resistance (Type S) | 10 MΩ | 10 MΩ | |||
● Type T | Yes | Yes | No | No | |
— Input resistance (Type T) | 10 MΩ | 10 MΩ | |||
● Type U | No | ||||
● Type TXK/TXK(L) to GOST | No | No | No | No | |
Input ranges (rated values), resistance thermometer | |||||
● Cu 10 | No | No | No | No | |
● Cu 10 according to GOST | No | No | No | No | |
● Cu 50 | No | No | No | No | |
● Cu 50 according to GOST | No | No | No | No | |
● Cu 100 | No | No | No | No | |
● Cu 100 according to GOST | No | No | No | No | |
● Ni 10 | No | No | No | No | |
● Ni 10 according to GOST | No | No | No | No | |
● Ni 100 | Yes; Standard/climate | Yes; Standard/climate | No | No | |
— Input resistance (Ni 100) | 10 MΩ | 10 MΩ | |||
● Ni 100 according to GOST | No | No | No | No | |
● Ni 1000 | Yes; Standard/climate | Yes; Standard/climate | No | No | |
— Input resistance (Ni 1000) | 10 MΩ | 10 MΩ | |||
● Ni 1000 according to GOST | No | No | No | No | |
● LG-Ni 1000 | Yes; Standard/climate | Yes; Standard/climate | No | No | |
— Input resistance (LG-Ni 1000) | 10 MΩ | 10 MΩ | |||
● Ni 120 | No | No | No | No | |
● Ni 120 according to GOST | No | No | No | No | |
● Ni 200 | No | No | No | ||
● Ni 200 according to GOST | No | No | No | No | |
● Ni 500 | No | No | No | No | |
● Ni 500 according to GOST | No | No | No | No | |
● Pt 10 | No | No | No | No | |
● Pt 10 according to GOST | No | No | No | No | |
● Pt 50 | No | No | No | No | |
● Pt 50 according to GOST | No | No | No | No | |
● Pt 100 | Yes; Standard/climate | Yes; Standard/climate | No | No | |
— Input resistance (Pt 100) | 10 MΩ | 10 MΩ | |||
● Pt 100 according to GOST | No | No | No | No | |
● Pt 1000 | Yes; Standard/climate | Yes; Standard/climate | No | No | |
— Input resistance (Pt 1000) | 10 MΩ | 10 MΩ | |||
● Pt 1000 according to GOST | No | No | No | No | |
● Pt 200 | Yes; Standard/climate | Yes; Standard/climate | No | No | |
— Input resistance (Pt 200) | 10 MΩ | 10 MΩ | |||
● Pt 200 according to GOST | No | No | No | No | |
● Pt 500 | Yes; Standard/climate | Yes; Standard/climate | No | No | |
— Input resistance (Pt 500) | 10 MΩ | 10 MΩ | |||
● Pt 500 according to GOST | No | No | No | No | |
Input ranges (rated values), resistors | |||||
● 0 to 150 ohms | Yes | Yes | No | No | |
— Input resistance (0 to 150 ohms) | 10 MΩ | 10 MΩ | |||
● 0 to 300 ohms | Yes | Yes | No | No | |
— Input resistance (0 to 300 ohms) | 10 MΩ | 10 MΩ | |||
● 0 to 600 ohms | Yes | Yes | No | No | |
— Input resistance (0 to 600 ohms) | 10 MΩ | 10 MΩ | |||
● 0 to 3000 ohms | No | No | No | No | |
● 0 to 6000 ohms | Yes | Yes | No | No | |
— Input resistance (0 to 6000 ohms) | 10 MΩ | 10 MΩ | |||
● PTC | Yes | Yes | No | No | |
— Input resistance (PTC) | 10 MΩ | 10 MΩ | |||
Thermocouple (TC) | |||||
Temperature compensation | |||||
— parameterizable | Yes | Yes | |||
— internal temperature compensation | Yes | Yes | |||
— external temperature compensation via RTD | Yes | Yes | |||
— Compensation for 0 °C reference point temperature | Yes; fixed value can be set | Yes; fixed value can be set | |||
— Reference channel of the module | No | Yes | |||
Cable length | |||||
● shielded, max. | 800 m; for U/I, 200 m for R/RTD, 50 m for TC | 800 m; for U/I, 200 m for R/RTD, 50 m for TC | 800 m | 800 m | |
Analog value generation for the inputs | |||||
Measurement principle | |||||
Integration and conversion time/resolution per channel | |||||
● Resolution with overrange (bit including sign), max. | 16 bit | 16 bit | 16 bit | 24 bit; When using the function “Scaling of the measured values” or “Measuring range adaptation” (32 bit REAL format); 16 bit when using the S7 format (16 bit INTEGER) | |
● Integration time, parameterizable | Yes | Yes | Yes | ||
● Integration time (ms) | 2,5 / 16,67 / 20 / 100 ms | 2,5 / 16,67 / 20 / 100 ms | Fast mode: 2.5 / 16.67 / 20 / 100 ms, standard mode: 7.5 / 50 / 60 / 300 ms | ||
● Basic conversion time, including integration time (ms) | 9 / 23 / 27 / 107 ms | 9 / 23 / 27 / 107 ms | Fast mode: 4 / 18 / 22 / 102 ms; Standard mode: 9 / 52 / 62 / 302 ms | ||
— additional conversion time for wire-break monitoring | 9 ms (to be considered in R/RTD/TC measurement) | 9 ms (to be considered in R/RTD/TC measurement) | |||
— additional conversion time for resistance measurement | 150 ohm, 300 ohm, 600 ohm, Pt100, Pt200, Ni100: 2 ms, 6000 ohm, Pt500, Pt1000, Ni1000, LG-Ni1000, PTC: 4 ms | 150 ohm, 300 ohm, 600 ohm, Pt100, Pt200, Ni100: 2 ms, 6000 ohm, Pt500, Pt1000, Ni1000, LG-Ni1000, PTC: 4 ms | |||
● Interference voltage suppression for interference frequency f1 in Hz | 400 / 60 / 50 / 10 | 400 / 60 / 50 / 10 Hz | 400 / 60 / 50 / 10 Hz | ||
● Basic execution time of the module (all channels released) | 62.5 µs; independent of number of activated channels | Corresponds to the channel with the highest basic conversion time | |||
● Time for offset calibration (per module) | Basic conversion time of the slowest channel | Basic conversion time of the slowest channel | |||
Smoothing of measured values | |||||
● parameterizable | Yes | Yes | Yes | Yes | |
● Step: None | Yes | Yes | Yes | Yes | |
● Step: low | Yes | Yes | Yes | Yes | |
● Step: Medium | Yes | Yes | Yes | Yes | |
● Step: High | Yes | Yes | Yes | Yes | |
Encoder | |||||
Connection of signal encoders | |||||
● for voltage measurement | Yes | Yes | Yes | Yes | |
● for current measurement as 2-wire transducer | Yes | Yes | Yes | Yes; with external transmitter supply | |
— Burden of 2-wire transmitter, max. | 820 Ω | 820 Ω | 820 Ω | ||
● for current measurement as 4-wire transducer | Yes | Yes | Yes | Yes | |
● for resistance measurement with two-wire connection | Yes; Only for PTC | Yes; Only for PTC | No | No | |
● for resistance measurement with three-wire connection | Yes; All measuring ranges except PTC; internal compensation of the cable resistances | Yes; All measuring ranges except PTC; internal compensation of the cable resistances | No | No | |
● for resistance measurement with four-wire connection | Yes; All measuring ranges except PTC | Yes; All measuring ranges except PTC | No | No | |
Errors/accuracies | |||||
Linearity error (relative to input range), (+/-) | 0.02 % | 0.02 % | 0.02 % | 0.02 % | |
Temperature error (relative to input range), (+/-) | 0.005 %/K; With TC type T 0.02 ± % / K | 0.005 %/K; With TC type T 0.02 ± % / K | 0.005 %/K | 0.005 %/K | |
Crosstalk between the inputs, max. | -80 dB | -80 dB | -60 dB | -80 dB | |
Repeat accuracy in steady state at 25 °C (relative to input range), (+/-) | 0.02 % | 0.02 % | 0.02 % | 0.02 % | |
Temperature error of internal compensation | ±6 °C | ±6 °C | |||
note regarding accuracy | at temperatures below 0 °C, the figures for operating error and temperature error are doubled | at temperatures below 0 °C, the figures for operating error and temperature error are doubled | |||
Operational error limit in overall temperature range | |||||
● Voltage, relative to input range, (+/-) | 0.3 % | 0.3 % | 0.3 % | 0.1 % | |
● Current, relative to input range, (+/-) | 0.3 % | 0.3 % | 0.3 % | 0.1 % | |
● Resistance, relative to input range, (+/-) | 0.3 % | 0.3 % | |||
● Resistance thermometer, relative to input range, (+/-) | 0.3 %; Ptxxx standard: ±1.5 K, Ptxxx climate: ±0.5 K, Nixxx standard: ±0.5 K, Nixxx climate: ±0.3 K | Ptxxx standard: ±1.5 K, Ptxxx climate: ±0.5 K, Nixxx standard: ±0.5 K, Nixxx climate: ±0.3 K | |||
● Thermocouple, relative to input range, (+/-) | 0.3 %; Type B: > 600 °C ±4.6 K, type E: > -200 °C ±1.5 K, type J: > -210 °C ±1.9 K, type K: > -200 °C ±2.4 K, type N: > -200 °C ±2.9 K, type R: > 0 °C ±4.7 K, type S: > 0 °C ±4.6 K, type T: > -200 °C ±2.4 K | Type B: > 600 °C ±4.6 K, type E: > -200 °C ±1.5 K, type J: > -210 °C ±1.9 K, type K: > -200 °C ±2.4 K, type N: > -200 °C ±2.9 K, type R: > 0 °C ±4.7 K, type S: > 0 °C ±4.6 K, type T: > -200 °C ±2.4 K | |||
Basic error limit (operational limit at 25 °C) | |||||
● Voltage, relative to input range, (+/-) | 0.1 % | 0.1 % | 0.2 % | 0.05 % | |
● Current, relative to input range, (+/-) | 0.1 % | 0.1 % | 0.2 % | 0.05 % | |
● Resistance, relative to input range, (+/-) | 0.1 % | 0.1 % | |||
● Resistance thermometer, relative to input range, (+/-) | 0.1 %; Ptxxx standard: ±0.7 K, Ptxxx climate: ±0.2 K, Nixxx standard: ±0.3 K, Nixxx climate: ±0.15 K | Ptxxx standard: ±0.7 K, Ptxxx climate: ±0.2 K, Nixxx standard: ±0.3 K, Nixxx climate: ±0.15 K | |||
● Thermocouple, relative to input range, (+/-) | 0.1 %; Type B: > 600 °C ±1.7 K, type E: > -200 °C ±0.7 K, type J: > -210 °C ±0.8 K, type K: > -200 °C ±1.2 K, type N: > -200 °C ±1.2 K, type R: > 0 °C ±1.9 K, type S: > 0 °C ±1.9 K, type T: > -200 °C ±0.8 K | Type B: > 600 °C ±1.7 K, type E: > -200 °C ±0.7 K, type J: > -210 °C ±0.8 K, type K: > -200 °C ±1.2 K, type N: > -200 °C ±1.2 K, type R: > 0 °C ±1.9 K, type S: > 0 °C ±1.9 K, type T: > -200 °C ±0.8 K | |||
Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency | |||||
● Series mode interference (peak value of interference < rated value of input range), min. | 40 dB | 40 dB | 80 dB; in the Standard operating mode, 40 dB in the Fast operating mode | ||
● Common mode voltage, max. | 10 V | 10 V | 10 V | 60 V DC/30 V AC | |
● Common mode interference, min. | 60 dB | 60 dB | 50 dB at 400 Hz; 60 dB at 60 / 50 / 10 Hz | 80 dB | |
Isochronous mode | |||||
Filtering and processing time (TCI), min. | 80 µs | ||||
Bus cycle time (TDP), min. | 250 µs | ||||
Interrupts/diagnostics/status information | |||||
Diagnostics function | Yes | Yes | Yes | Yes | |
Alarms | |||||
● Diagnostic alarm | Yes | Yes | Yes | Yes | |
● Limit value alarm | Yes; two upper and two lower limit values in each case | Yes; two upper and two lower limit values in each case | Yes; two upper and two lower limit values in each case | Yes; two upper and two lower limit values in each case | |
Diagnoses | |||||
● Monitoring the supply voltage | Yes | Yes | Yes | Yes | |
● Wire-break | Yes; Only for 1 to 5 V, 4 to 20 mA, TC, R, and RTD | Yes; Only for 1 to 5 V, 4 to 20 mA, TC, R, and RTD | Yes; only for 1 … 5 V and 4 … 20 mA | Yes; only for 1 … 5 V and 4 … 20 mA | |
● Short-circuit | |||||
● Group error | |||||
● Overflow/underflow | Yes | Yes | Yes | Yes | |
Diagnostics indication LED | |||||
● RUN LED | Yes; green LED | Yes; green LED | Yes; green LED | Yes; green LED | |
● ERROR LED | Yes; red LED | Yes; red LED | Yes; red LED | Yes; red LED | |
● MAINT LED | |||||
● Monitoring of the supply voltage (PWR-LED) | Yes; green LED | Yes; green LED | Yes; green LED | Yes; green LED | |
● Channel status display | Yes; green LED | Yes; green LED | Yes; green LED | Yes; green LED | |
● for channel diagnostics | Yes; red LED | Yes; red LED | Yes; red LED | Yes; red LED | |
● for module diagnostics | Yes; red LED | Yes; red LED | Yes; red LED | Yes; red LED | |
Potential separation | |||||
Potential separation channels | |||||
● between the channels | No | No | No | Yes | |
● between the channels, in groups of | 4 | 8 | 8 | 1 | |
● between the channels and backplane bus | Yes | Yes | Yes | Yes | |
● between the channels and the power supply of the electronics | Yes | Yes | Yes | Yes | |
Permissible potential difference | |||||
between different circuits | 60 V DC/30 V AC; insulation rated for 120 V AC basic insulation: between the channels and the supply voltage L+; between the channels and the backplane bus; between the channels | ||||
between the inputs (UCM) | 20 V DC | 20 V DC | 20 V DC | ||
Between the inputs and MANA (UCM) | 10 V DC | 10 V DC | 10 V DC | ||
Isolation | |||||
Isolation tested with | 707 V DC (type test) | 707 V DC (type test) | 707 V DC (type test) | 2 000 V DC between the channels and the supply voltage L+; 2 000 V DC between the channels and the backplane bus; 2 000 V DC between the channels; 707 V DC (type test) between the supply voltage L+ and the backplane bus | |
Standards, approvals, certificates | |||||
Suitable for applications according to AMS 2750 | Yes; Declaration of Conformity, see online support entry 109757262 | ||||
Suitable for applications according to CQI-9 | Yes; Based on AMS 2750 E | ||||
Ambient conditions | |||||
Ambient temperature during operation | |||||
● horizontal installation, min. | -25 °C; From FS03 | 0 °C | -25 °C; From FS02 | -30 °C; From FS02 | |
● horizontal installation, max. | 60 °C | 60 °C | 60 °C | 60 °C | |
● vertical installation, min. | -25 °C; From FS03 | 0 °C | -25 °C; From FS02 | -30 °C; From FS02 | |
● vertical installation, max. | 40 °C | 40 °C | 40 °C | 40 °C | |
Altitude during operation relating to sea level | |||||
● Installation altitude above sea level, max. | 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual | 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual | 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual | ||
Dimensions | |||||
Width | 25 mm | 35 mm | 35 mm | 35 mm | |
Height | 147 mm | 147 mm | 147 mm | 147 mm | |
Depth | 129 mm | 129 mm | 129 mm | 129 mm | |
Weights | |||||
Weight, approx. | 210 g | 310 g | 300 g | 280 g | |
Other | |||||
Note: | Supplied incl. 40-pole push-in front connectors. Additional basic error and noise for integration time = 2.5 ms: Voltage: ±250 mV (±0.02%), ±80 mV (±0.05%), ±50 mV (±0.05%); resistance: 150 Ohms (±0.02%); resistance thermometer: Pt100 climate: ±0.08 K, Ni100 climate: ±0.08 K; thermoelement: Type B, R, S: ±3 K, type E, J, K, N, T: ±1 K | Additional basic error and noise for integration time = 2.5 ms: Voltage: ±250 mV (±0.02%), ±80 mV (±0.05%), ±50 mV (±0.05%); resistance: 150 ohms ±0.02%; resistance thermometer: Pt100 climate: ±0.08 K, Ni100 climate: ±0.08 K; thermocouple: Type B, R, S: ±3 K, type E, J, K, N, T: ±1 K |
Article number | 6ES7531-7PF00-0AB0 | |
S7-1500, AI 8 X U/R/RTD/TC HF | ||
General information | ||
Product type designation | AI 8xU/R/RTD/TC HF | |
HW functional status | FS01 | |
Firmware version | V1.1.0 | |
● FW update possible | Yes | |
Product function | ||
● I&M data | Yes; I&M0 to I&M3 | |
● Isochronous mode | No | |
● Prioritized startup | Yes | |
● Measuring range scalable | Yes | |
● Scalable measured values | No | |
● Adjustment of measuring range | No | |
Engineering with | ||
● STEP 7 TIA Portal configurable/integrated from version | V14 / – | |
● STEP 7 configurable/integrated from version | V5.5 SP3 / – | |
● PROFIBUS from GSD version/GSD revision | V1.0 / V5.1 | |
● PROFINET from GSD version/GSD revision | V2.3 / – | |
Operating mode | ||
● Oversampling | No | |
● MSI | Yes | |
CiR – Configuration in RUN | ||
Reparameterization possible in RUN | Yes | |
Calibration possible in RUN | Yes | |
Supply voltage | ||
Rated value (DC) | 24 V | |
permissible range, lower limit (DC) | 19.2 V | |
permissible range, upper limit (DC) | 28.8 V | |
Reverse polarity protection | Yes | |
Input current | ||
Current consumption, max. | 55 mA; with 24 V DC supply | |
Power | ||
Power available from the backplane bus | 0.85 W | |
Power loss | ||
Power loss, typ. | 1.9 W | |
Analog inputs | ||
Number of analog inputs | 8; Plus one additional RTD (reference) channel | |
● For voltage measurement | 8; Plus one additional RTD (reference) channel | |
● For resistance/resistance thermometer measurement | 8; Plus one additional RTD (reference) channel | |
● For thermocouple measurement | 8; Plus one additional RTD (reference) channel | |
permissible input voltage for voltage input (destruction limit), max. | 20 V | |
Constant measurement current for resistance-type transmitter, typ. | 150 Ohm, 300 Ohm, 600 Ohm, Cu10, Cu50, Cu100, Ni10, Ni100, Ni120, Ni200, Pt10, Pt50, Pt100, Pt200 climate: 1 mA; 6 kOhm, Ni500, Ni1000, LG-Ni1000, Pt200 standard, Pt500, Pt1000, PTC: 0.25 mA | |
Technical unit for temperature measurement adjustable | Yes; °C/°F/K | |
Input ranges (rated values), voltages | ||
● 0 to +5 V | No | |
● 0 to +10 V | No | |
● 1 V to 5 V | No | |
● -1 V to +1 V | Yes | |
— Input resistance (-1 V to +1 V) | 10 MΩ | |
● -10 V to +10 V | No | |
● -2.5 V to +2.5 V | No | |
● -25 mV to +25 mV | Yes | |
— Input resistance (-25 mV to +25 mV) | 10 MΩ | |
● -250 mV to +250 mV | Yes | |
— Input resistance (-250 mV to +250 mV) | 10 MΩ | |
● -5 V to +5 V | No | |
● -50 mV to +50 mV | Yes | |
— Input resistance (-50 mV to +50 mV) | 10 MΩ | |
● -500 mV to +500 mV | Yes | |
— Input resistance (-500 mV to +500 mV) | 10 MΩ | |
● -80 mV to +80 mV | Yes | |
— Input resistance (-80 mV to +80 mV) | 10 MΩ | |
Input ranges (rated values), currents | ||
● 0 to 20 mA | No | |
● -20 mA to +20 mA | No | |
● 4 mA to 20 mA | No | |
Input ranges (rated values), thermocouples | ||
● Type B | Yes | |
— Input resistance (Type B) | 10 MΩ | |
● Type C | Yes | |
— Input resistance (Type C) | 10 MΩ | |
● Type E | Yes | |
— Input resistance (Type E) | 10 MΩ | |
● Type J | Yes | |
— Input resistance (type J) | 10 MΩ | |
● Type K | Yes | |
— Input resistance (Type K) | 10 MΩ | |
● Type L | No | |
● Type N | Yes | |
— Input resistance (Type N) | 10 MΩ | |
● Type R | Yes | |
— Input resistance (Type R) | 10 MΩ | |
● Type S | Yes | |
— Input resistance (Type S) | 10 MΩ | |
● Type T | Yes | |
— Input resistance (Type T) | 10 MΩ | |
● Type TXK/TXK(L) to GOST | Yes | |
— Input resistance (Type TXK/TXK(L) to GOST) | 10 MΩ | |
Input ranges (rated values), resistance thermometer | ||
● Cu 10 | Yes; Standard/climate | |
— Input resistance (Cu 10) | 10 MΩ | |
● Cu 10 according to GOST | Yes; Standard/climate | |
— Input resistance (Cu 10 according to GOST) | 10 MΩ | |
● Cu 50 | Yes; Standard/climate | |
— Input resistance (Cu 50) | 10 MΩ | |
● Cu 50 according to GOST | Yes; Standard/climate | |
— Input resistance (Cu 50 according to GOST) | 10 MΩ | |
● Cu 100 | Yes; Standard/climate | |
— Input resistance (Cu 100) | 10 MΩ | |
● Cu 100 according to GOST | Yes; Standard/climate | |
— Input resistance (Cu 100 according to GOST) | 10 MΩ | |
● Ni 10 | Yes; Standard/climate | |
— Input resistance (Ni 10) | 10 MΩ | |
● Ni 10 according to GOST | Yes; Standard/climate | |
— Input resistance (Ni 10 according to GOST) | 10 MΩ | |
● Ni 100 | Yes; Standard/climate | |
— Input resistance (Ni 100) | 10 MΩ | |
● Ni 100 according to GOST | Yes; Standard/climate | |
— Input resistance (Ni 100 according to GOST) | 10 MΩ | |
● Ni 1000 | Yes; Standard/climate | |
— Input resistance (Ni 1000) | 10 MΩ | |
● Ni 1000 according to GOST | Yes; Standard/climate | |
— Input resistance (Ni 1000 according to GOST) | 10 MΩ | |
● LG-Ni 1000 | Yes; Standard/climate | |
— Input resistance (LG-Ni 1000) | 10 MΩ | |
● Ni 120 | Yes; Standard/climate | |
— Input resistance (Ni 120) | 10 MΩ | |
● Ni 120 according to GOST | Yes; Standard/climate | |
— Input resistance (Ni 120 according to GOST) | 10 MΩ | |
● Ni 200 | Yes; Standard/climate | |
— Input resistance (Ni 200) | 10 MΩ | |
● Ni 200 according to GOST | Yes; Standard/climate | |
— Input resistance (Ni 200 according to GOST) | 10 MΩ | |
● Ni 500 | Yes; Standard/climate | |
— Input resistance (Ni 500) | 10 MΩ | |
● Ni 500 according to GOST | Yes; Standard/climate | |
— Input resistance (Ni 500 according to GOST) | 10 MΩ | |
● Pt 10 | Yes; Standard/climate | |
— Input resistance (Pt 10) | 10 MΩ | |
● Pt 10 according to GOST | Yes; Standard/climate | |
— Input resistance (Pt 10 according to GOST) | 10 MΩ | |
● Pt 50 | Yes; Standard/climate | |
— Input resistance (Pt 50) | 10 MΩ | |
● Pt 50 according to GOST | Yes; Standard/climate | |
— Input resistance (Pt 50 according to GOST) | 10 MΩ | |
● Pt 100 | Yes; Standard/climate | |
— Input resistance (Pt 100) | 10 MΩ | |
● Pt 100 according to GOST | Yes; Standard/climate | |
— Input resistance (Pt 100 according to GOST) | 10 MΩ | |
● Pt 1000 | Yes; Standard/climate | |
— Input resistance (Pt 1000) | 10 MΩ | |
● Pt 1000 according to GOST | Yes; Standard/climate | |
— Input resistance (Pt 1000 according to GOST) | 10 MΩ | |
● Pt 200 | Yes; Standard/climate | |
— Input resistance (Pt 200) | 10 MΩ | |
● Pt 200 according to GOST | Yes; Standard/climate | |
— Input resistance (Pt 200 according to GOST) | 10 MΩ | |
● Pt 500 | Yes; Standard/climate | |
— Input resistance (Pt 500) | 10 MΩ | |
● Pt 500 according to GOST | Yes; Standard/climate | |
— Input resistance (Pt 500 according to GOST) | 10 MΩ | |
Input ranges (rated values), resistors | ||
● 0 to 150 ohms | Yes | |
— Input resistance (0 to 150 ohms) | 10 MΩ | |
● 0 to 300 ohms | Yes | |
— Input resistance (0 to 300 ohms) | 10 MΩ | |
● 0 to 600 ohms | Yes | |
— Input resistance (0 to 600 ohms) | 10 MΩ | |
● 0 to 3000 ohms | No | |
● 0 to 6000 ohms | Yes | |
— Input resistance (0 to 6000 ohms) | 10 MΩ | |
● PTC | Yes | |
— Input resistance (PTC) | 10 MΩ | |
Thermocouple (TC) | ||
Temperature compensation | ||
— parameterizable | Yes | |
— internal temperature compensation | Yes | |
— external temperature compensation via RTD | Yes | |
— Compensation for 0 °C reference point temperature | Yes; fixed value can be set | |
— Reference channel of the module | Yes; 9th channel that can be used as a genuine 9th RTD channel regardless of the parameterization of the other channels, or that can be used for compensation in the case of TC measurement | |
Cable length | ||
● shielded, max. | 800 m; at U; 200 m at R/RTD/TC | |
Analog value generation for the inputs | ||
Integration and conversion time/resolution per channel | ||
● Resolution with overrange (bit including sign), max. | 21 bit; For measuring mode RTC and TC when using the function “Scalable temperature measuring range” (32 bit REAL format); 16 bit for measuring mode R and U; 16 bit for all measuring modes when using the S7 format (16 bit INTEGER) | |
● Integration time, parameterizable | Yes | |
● Integration time (ms) | Fast mode: 2.5 / 16.67 / 20 / 100 ms, standard mode: 7.5 / 50 / 60 / 300 ms | |
● Basic conversion time, including integration time (ms) | Fast mode: 4 / 18 / 22 / 102 ms; Standard mode: 9 / 52 / 62 / 302 ms | |
— additional conversion time for wire-break monitoring | Thermocouples, 150 Ohm, 300 Ohm, 600 Ohm, Cu10, Cu50, Cu100, Ni10, Ni100, Ni120, Ni200, Pt10, Pt50, Pt100: 4 ms; 6 kOhm, Ni500, Ni1000, LG-Ni1000, Pt200, Pt500, Pt1000: 13 ms | |
● Interference voltage suppression for interference frequency f1 in Hz | 400 / 60 / 50 / 10 Hz | |
● Basic execution time of the module (all channels released) | Corresponds to the channel with the highest basic conversion time | |
Smoothing of measured values | ||
● parameterizable | Yes | |
● Step: None | Yes | |
● Step: low | Yes | |
● Step: Medium | Yes | |
● Step: High | Yes | |
Encoder | ||
Connection of signal encoders | ||
● for voltage measurement | Yes | |
● for current measurement as 2-wire transducer | No | |
● for current measurement as 4-wire transducer | No | |
● for resistance measurement with two-wire connection | Yes | |
● for resistance measurement with three-wire connection | Yes; All measuring ranges except PTC; internal compensation of the cable resistances | |
● for resistance measurement with four-wire connection | Yes; All measuring ranges except PTC | |
Errors/accuracies | ||
Linearity error (relative to input range), (+/-) | 0.02 % | |
Temperature error (relative to input range), (+/-) | 0.005 %/K | |
Crosstalk between the inputs, max. | -80 dB | |
Repeat accuracy in steady state at 25 °C (relative to input range), (+/-) | 0.02 % | |
Temperature error of internal compensation | ±1,5 °C | |
Operational error limit in overall temperature range | ||
● Voltage, relative to input range, (+/-) | 0.1 % | |
● Resistance, relative to input range, (+/-) | 0.1 % | |
● Resistance thermometer, relative to input range, (+/-) | Cuxxx Standard: ±0.5 K, Cuxxx Klima: ±0.5 K, Ptxxx Standard: ±1 K, Ptxxx Klima: ±0.5 K, Nixxx Standard: ±0.5 K, Nixxx Klima: ±0.3 K | |
● Thermocouple, relative to input range, (+/-) | Type B: > 600 °C ±2 K, Type E: > -200 °C ±1 K, Type J: > -210 °C ±1 K, Type K: > -200 °C ±2 K, Type N: > -200 °C ±2 K, Type R: > 0 °C ±2 K, Type S: > 0 °C ±2 K, Type T: > -200 °C ±1 K, Type C: ±4 K, Type TXK/TXK(L): ±1 K | |
Basic error limit (operational limit at 25 °C) | ||
● Voltage, relative to input range, (+/-) | 0.05 % | |
● Resistance, relative to input range, (+/-) | 0.05 % | |
● Resistance thermometer, relative to input range, (+/-) | Cuxxx Standard: ±0.3 K, Cuxxx Klima: ±0.2 K, Ptxxx Standard: ±0.5 K, Ptxxx Klima: ±0.2 K, Nixxx Standard: ±0.3 K, Nixxx Klima: ±0.15 K | |
● Thermocouple, relative to input range, (+/-) | Type B: > 600 °C ±1 K, Type E: > -200 °C ±0.5 K, Type J: > -210 °C ±0.5 K, Type K: > -200 °C ±1 K, Type N: > -200 °C ±1 K, Type R: > 0 °C ±1 K, Type S: > 0 °C ±1 K, Type T: > -200 °C ±0.5 K, Type C: ±2 K, Type TXK/TXK(L): ±0.5 K | |
Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency | ||
● Series mode interference (peak value of interference < rated value of input range), min. | 80 dB; in the Standard operating mode, 40 dB in the Fast operating mode | |
● Common mode voltage, max. | 60 V DC/30 V AC | |
● Common mode interference, min. | 80 dB | |
Interrupts/diagnostics/status information | ||
Diagnostics function | Yes | |
Alarms | ||
● Diagnostic alarm | Yes | |
● Limit value alarm | Yes; two upper and two lower limit values in each case | |
Diagnoses | ||
● Monitoring the supply voltage | Yes | |
● Wire-break | Yes; Only with TC, R, RTD | |
● Overflow/underflow | Yes | |
Diagnostics indication LED | ||
● RUN LED | Yes; green LED | |
● ERROR LED | Yes; red LED | |
● Monitoring of the supply voltage (PWR-LED) | Yes; green LED | |
● Channel status display | Yes; green LED | |
● for channel diagnostics | Yes; red LED | |
● for module diagnostics | Yes; red LED | |
Potential separation | ||
Potential separation channels | ||
● between the channels | Yes | |
● between the channels, in groups of | 1 | |
● between the channels and backplane bus | Yes | |
● between the channels and the power supply of the electronics | Yes | |
Permissible potential difference | ||
between different circuits | 60 V DC/30 V AC; insulation rated for 120 V AC basic insulation: between the channels and the supply voltage L+; between the channels and the backplane bus; between the channels | |
Isolation | ||
Isolation tested with | 2 000 V DC between the channels and the supply voltage L+; 2 000 V DC between the channels and the backplane bus; 2 000 V DC between the channels; 707 V DC (type test) between the supply voltage L+ and the backplane bus | |
Standards, approvals, certificates | ||
Suitable for applications according to AMS 2750 | Yes; Declaration of Conformity, see online support entry 109757262 | |
Suitable for applications according to CQI-9 | Yes; Based on AMS 2750 E | |
Ambient conditions | ||
Ambient temperature during operation | ||
● horizontal installation, min. | 0 °C | |
● horizontal installation, max. | 60 °C | |
● vertical installation, min. | 0 °C | |
● vertical installation, max. | 40 °C | |
Dimensions | ||
Width | 35 mm | |
Height | 147 mm | |
Depth | 129 mm | |
Weights | ||
Weight, approx. | 290 g | |
Other | ||
Note: | for the R/RDT three-wire measurement, the conductor compensation is made alternating with the measurement; this then requires two module cycles for a measured value |
Weight | N/A |
---|---|
Dimensions | N/A |