WLG4SC-3P2232A70 Miniature Photoelectric Sensors – SICK Sensor

$ 229.02

SKU: SICK 1067763

SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.

Part Number:1067763
Photoelectric Sensor Model:WLG4SC-3P2232A70
OEM Spec Ref 

Features

Device type Photoelectric sensors
Sensor/ detection principle Photoelectric retro-reflective sensor, autocollimation
Dimensions (W x H x D) 12.2 mm x 41.8 mm x 17.3 mm
Housing design (light emission) Rectangular
Sensing range max. 0 m … 5 m 1)
Sensing range 0 m … 3 m 1)
Type of light Visible red light
Light source PinPoint LED 2)
Light spot size (distance) Ø 45 mm (1.5 m)
Wave length 650 nm
Adjustment IO-Link

Single teach-in button

Pin 2 configuration External input, Teach-in input, Sender off input, Detection output, logic output, Device contamination alarm output
AutoAdapt
Special applications Detecting transparent objects
  • 1) Reflector PL80A.
  • 2) Average service life: 100,000 h at TU = +25 °C.

Mechanics/electronics

Supply voltage 10 V DC … 30 V DC 1)
Ripple < 5 Vpp 2)
Current consumption 20 mA 3)
Switching output PNP
Switching mode Light/dark switching
Output current Imax. ≤ 100 mA
Response time Q/ on Pin 2 300 µs … 450 µs 4) 5)
Switching frequency 1,000 Hz
Switching frequency Q / to pin 2 1,000 Hz 6)
Attenuation along light beam > 8 %
Connection type Male connector M8, 4-pin
Circuit protection 7)

8)

9)

10)

Protection class III
Weight 30 g
Polarisation filter
Housing material Plastic, ABS
Optics material Plastic, PMMA
Enclosure rating IP67

IP66

Special feature Detecting transparent objects
Ambient operating temperature –40 °C … +60 °C
Ambient temperature, storage –40 °C … +75 °C
UL File No. NRKH.E181493 & NRKH7.E181493
Repeatability Q/ on Pin 2: 150 µs 5)
  • 1) Limit values when operated in short-circuit protected network: max. 8 A.
  • 2) May not exceed or fall below Uv tolerances.
  • 3) Without load.
  • 4) Signal transit time with resistive load.
  • 5) Valid for Q on Pin2, if configured with software.
  • 6) With light / dark ratio 1:1, valid for Q on Pin2, if configured with software.
  • 7) A = VS connections reverse-polarity protected.
  • 8) B = inputs and output reverse-polarity protected.
  • 9) C = interference suppression.
  • 10) D = outputs overcurrent and short-circuit protected.

Safety-related parameters

MTTFD 1,222 years
DCavg 0 %

Communication interface

Communication interface IO-Link V1.1
Communication Interface detail COM2 (38,4 kBaud)
Cycle time 2.3 ms
Process data length 16 Bit
Process data structure Bit 0 = switching signal QL1

Bit 1 = switching signal QL2

Bit 2 … 15 = measuring value

VendorID 26
DeviceID HEX 0x8000DE
DeviceID DEC 8388830

Smart Task

Smart Task name Time measurement + debouncing
Logic function Direct

WINDOW

Timer function Deactivated

On delay

Off delay

ON and OFF delay

Impulse (one shot)

Inverter Yes
Response time 1)

2)

Time measurement accuracy SIO Direct: —

SIO Logic: – 0,7 … + 0,7 ms ± 0,5 % of time measurement value

IOL: – 0.9 … + 0.9 ms ± 0.5% of the time measurement

Repeatability 1)

2)

Time measurement accuracy (e.g. accuracy for time measurement value = 1 s ) SIO Direct: —

SIO Logic: – 5,7 … + 5,7 ms

IOL: – 5,9 … + 5,9 ms

Resolution time measuring value 1 ms
Min. Time between two process events (switches) SIO Direct: —

SIO Logic: 450 µs

IOL: 500 µs

Debounce time max. SIO Direct: —

SIO Logic: 30.000 ms

IOL: 30.000 ms

Switching signal
Switching signal QL1 Output type (dependant on the adjusted threshold)
Switching signal QL2 Output type (dependant on the adjusted threshold)
Measuring value Time measurement value
  • 1) SIO Logic: Sensor operation in standard I/O mode without IO-Link communication. Sensor-internal logic or timing parameters plus Automation Functions used.
  • 2) IOL: Sensor operation with full IO-Link communication and usage of logic, timing and Automation Function parameters.

Diagnosis

Status information
Device status Yes
Quality of teach Yes
Quality of run Yes, Contamination display