Precision SICK OD Mini (6050496) laser displacement sensor. Features 10-20mm range, 1µm resolution, and CMOS technology for high-accuracy industrial measurement.
The SICK OD1-B015H05I25 (6050496) is a high-performance member of the OD Mini displacement sensor family, engineered for precision in the most compact environments. Utilizing advanced CMOS laser triangulation technology, this sensor provides reliable distance measurement regardless of the target’s color or surface texture, including shiny or dark materials. With a specialized measuring range of 10 mm to 20 mm and a remarkable resolution of 1 µm, it is ideal for high-accuracy quality control and positioning tasks.
Its miniaturized design allows for seamless integration into small machines and robotic arms where space is at a premium. The sensor features a user-friendly interface with a clear digital display and tactile buttons, enabling rapid commissioning without external software. The rugged IP67-rated aluminum housing ensures long-term durability in harsh industrial conditions. Whether monitoring precise component tolerances or ensuring exact assembly placement, the OD Mini delivers exceptional linearity and repeatability, making it a cornerstone for automated precision manufacturing.
| Supply voltage Vs | DC 12 V (–5 %) … DC 24 V (+10 %) |
| Power consumption | ≤ 1.92 W 1) |
| Warm-up time | ≤ 5 min |
| Housing material | Stainless steel |
| Window material | Plastic (PPSU) |
| Connection type | Cable with male connector, M12, 5-pin, 30 cm |
| Indication | 4-digit 7-segment display (plus 4 LEDs for status display) |
| Control elements | 4 buttons |
| Weight | 70 g |
| Dimensions (W x H x D) | 17.8 mm x 44.4 mm x 31 mm |
| Enclosure rating | IP67 |
| Protection class | III |
| Measuring range | 10 mm … 20 mm |
| Target | Natural objects |
| Repeatability | 1 µm 1) 2) |
| Linearity | ± 10 µm 3) |
| Response time | ≥ 2 ms 4) |
| Measuring frequency | ≤ 2 kHz |
| Output time | ≥ 0.5 ms |
| Light source | Laser, red visible red light |
| Laser class | 1 (IEC 60825-1:2014, EN 60825-1:2014) 5) |
| Typ. light spot size (distance) | 700 µm x 500 µm (15 mm) |
| Additional function | Averaging 1 … 512x, automatic or manual sensitivity adjustment, Analog outputs can be taught in, digital outputs can be taught in, invertable digital output, switching mode: window (Wnd), switching mode: distance to object (DtO), switiching mode: object between sensor and background (ObSB), multifunctional input: laser-off / external teach-in / trigger |
|
|||||||||||
|
|||||||||||
| Multifunctional input (MF) | 1 x 1) | ||||||||||
| Ambient temperature, operation | –10 °C … +50 °C |
| Ambient temperature, storage | –20 °C … +60 °C |
| Min. rel. humidity (not condensing) | 35 % |
| Max. rel. humidity (not condensing) | 95 % |
| Temperature drift | ± 0.08 % FS/K (FS = Full Scale = Measuring range of sensor) |
| Typ. Ambient light immunity | Artificial light: ≤ 3,000 lx
Sunlight: ≤ 10,000 lx |
| Vibration resistance | 10 Hz … 55 Hz (amplitude 1.5 mm, x-, y-, z-axis 2 hours each) |
| Shock resistance | 50 G (x, y, z axis 3 times each) |