SPAU-V1R-A-Q4-L-PNLK-PNVBA-M8 – Pressure Sensor – Festo Pressure Sensors and Vacuum Sensors

$ 251.85 $ 201.48

SKU: Festo 8001200 #03

Manufacturer Part Number: Festo 8001200 #03
Festo Pressure Sensors and Vacuum Sensors: SPAU-V1R-A-Q4-L-PNLK-PNVBA-M8
OEM Spec Ref 

The Festo SPAU-V1R-A-Q4-L-PNLK-PNVBA-M8, MPN 8001200, is an advanced Pressure and Vacuum Sensor engineered to ensure accurate monitoring and control in various industrial applications. Here’s a detailed description to help with SEO:

Key Features:

  • High Precision Monitoring: Ensures exact measurements of pressure and vacuum levels, critical for maintaining operational accuracy.
  • Robust Design: Built with durable materials, it is capable of withstanding the demanding conditions of industrial environments.
  • Compact and Flexible: Its compact size facilitates easy installation in space-limited areas while maintaining high functionality.
  • User-Friendly Interface: Features an intuitive user interface for hassle-free operation and adjustments.
  • Versatile Compatibility: Designed to integrate seamlessly with numerous industrial systems, enhancing adaptability and ease of use.

Benefits:

  • Optimal System Performance: By providing accurate data, it helps optimize the efficiency and reliability of pressure and vacuum systems.
  • Energy Efficiency: Contributes to reduced energy consumption by maintaining precise control over system pressures.
  • Extended Equipment Life: Helps in preventing overpressure and vacuum conditions that can lead to premature equipment failure.
  • Enhanced Safety: Ensures safer operation by providing dependable and consistent monitoring.

Applications:

  • Manufacturing: Critical for processes requiring precise pressure and vacuum control to ensure product quality.
  • Automation Systems: Plays a key role in automated setups where stable pressure and vacuum levels are necessary for consistent operation.
  • Testing and Inspection: Ideal for environments that depend on precise measurements for accurate testing and evaluation.
  • General Industrial: Suitable for a wide range of industrial applications, from machinery operation to system testing.

The Festo SPAU-V1R-A-Q4-L-PNLK-PNVBA-M8 stands out as a reliable and efficient solution for managing pressure and vacuum conditions, reflecting Festo’s commitment to high-quality and innovative industrial solutions.

Technical Data

Feature Specification
Symbol 00995410
00995411
00995412
Certification RCM compliance mark
c UL us – Listed (OL)
CE marking (see declaration of conformity) As per EU EMC directive
As per EU RoHS directive
UKCA marking (see declaration of conformity To UK instructions for EMC
To UK RoHS instructions
KC characters KC EMC
Note on materials RoHS-compliant
Measured variable Relative pressure
Method of measurement Piezoresistive pressure sensor
Pressure measuring range initial value -0.1 MPa
Pressure measuring range initial value -1 bar
Pressure measuring range initial value -14.5 psi
Pressure measuring range end value 1.6 MPa
Pressure measuring range end value 16 bar
Pressure measuring range end value 232 psi
Max. overload pressure 20 bar
overload pressure 2 MPa
overload pressure 20 bar
overload pressure 290 psi
Operating medium Compressed air as per ISO 8573-1:2010 [7:4:4] Inert gas
Information on operating and pilot media Operation with oil lubrication possible
Temperature of medium 0 °C … 50 °C
Ambient temperature 0 °C … 50 °C
ADC resolution 12 bit
Accuracy in ± % FS 1.5 %FS
Repetition accuracy in ± %FS 0.3 %FS
Temperature co-efficient in ± %FS/K 0.05 %FS/K
Switching output 2 x PNP or 2 x NPN switchable
2xPNP
Switching function Freely programmable
Switching element function N/C contact/N/O contact switchable
Max. output current 100 mA
Analog output 0 – 10 V
4 – 20 mA
1 – 5 V
Rise time 3 ms
Max. load resistance of current output 500 Ohm
Min. load resistance of voltage output 10 kOhm
Short-circuit protection yes
Protocol IO-Link®
IO-Link®, protocol version Device V 1.1
IO-Link®, profile Smart sensor profile
IO-Link®, function classes Binary data channel (BDC)
Process data variable (PDV)
Identification
Diagnostics
Teach channel
IO-Link®, communication mode COM2 (38,4 kBd)
IO-Link®, SIO mode support Yes
IO-Link®, port class A
IO-Link®, process data width OUT 0 Byte
IO-Link®, process data width IN 2 Byte
IO-Link®, process data content IN 14 bit PDV (pressure measurement)
2 bit BDC (pressure monitoring)
IO-Link®, minimum cycle time 3 ms
IO-Link®, data memory required 500 byte
DC operating voltage range 20 V … 30 V
Reverse polarity protection for all electrical connections
Electrical connection 1, connection type Plug
Electrical connection 1, connection technology M12x1 A-coded as per EN 61076-2-101
M8x1 A-coded as per EN 61076-2-104
Electrical connection 1, number of pins/wires 4
Electrical connection for input 1, connection pattern 00991171
00995386
Type of mounting Optionally:
Front panel mounting
On service unit
With thread
With H-rail
With wall/surface bracket
Mounting position Any
Pneumatic connection M5
M7
G1/8
R1/8
R1/4
1/8 NPT
QS-4
QS-6
QS-5/32
Product weight 65 g … 80 g
Display type Illuminated LCD
LED
Displayable unit(s) MPa
bar
inH2O
inHg
kPa
kgf/cm²
mmHg
psi
Setting options IO-Link®
Teach-in
Via display and pushbuttons
Protection against tampering IO-Link®
PIN code
Setting range threshold value 0 % … 100 %
Setting range hysteresis 0 % … 90 %
Degree of protection IP65
IP67
Corrosion resistance class (CRC) 2 – Moderate corrosion stress
LABS (PWIS) conformity VDMA24364-B1/B2-L