WTF12G-3P2432 MultiTask Photoelectric Sensors – SICK Sensor

$ 224.40

SKU: SICK 1065719

SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.

Part Number:1065719
Photoelectric Sensor Model:WTF12G-3P2432
OEM Spec Ref 

Features

Sensor/ detection principle Photoelectric proximity sensor, Foreground suppression
Dimensions (W x H x D) 15.6 mm x 48.5 mm x 42 mm
Housing design (light emission) Rectangular
Sensing range max. 150 mm … 700 mm 1)
Sensing range 0 mm … 400 mm 2)
Type of light Visible red light
Light source PinPoint LED 3)
Light spot size (distance) Ø 8 mm (300 mm)
Wave length 660 nm
Adjustment Single teach-in button
Special applications Detecting transparent objects, Detecting uneven, shiny objects
  • 1) Adjustable background; referring to the background with 90 % remission (based on glass-bead blasted stainless steel, equivalent to standard white DIN 5033).
  • 2) Detection range transparent objects.
  • 3) Average service life: 100,000 h at TU = +25 °C.

Mechanics/electronics

Supply voltage 10 V DC … 30 V DC 1)
Ripple ≤ 5 Vpp 2)
Current consumption 55 mA 3)
Switching output PNP
Output function Complementary
Switching mode Light/dark switching
Signal voltage PNP HIGH/LOW > Uv – 2,5 V / ca. 0 V
Output current Imax. 100 mA
Response time 2 ms 4)
Switching frequency 250 Hz 5)
Connection type Male connector M12, 4-pin
Circuit protection 6)

7)

8)

Protection class II
Weight 120 g
Housing material Metal
Enclosure rating IP66

IP67

Special feature Detecting transparent objects
Ambient operating temperature –40 °C … +60 °C
Ambient storage temperature –40 °C … +75 °C
UL File No. NRKH.E181493 & NRKH7.E181493
  • 1) Limit values when operated in short-circuit protected network: max. 8 A.
  • 2) May not exceed or fall below Uv tolerances.
  • 3) Without load.
  • 4) Signal transit time with resistive load.
  • 5) With light/dark ratio 1:1.
  • 6) A = VS connections reverse-polarity protected.
  • 7) C = interference suppression.
  • 8) D = outputs overcurrent and short-circuit protected.

Safety-related parameters

MTTFD 508 years
DCavg 0%