WTB4SLC-3P2262A00 Miniature Photoelectric Sensors – SICK Sensor
$ 269.33
SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.
Part Number:1080939
Photoelectric Sensor Model:WTB4SLC-3P2262A00
OEM Spec Ref
Features
Sensor/ detection principle | Photoelectric proximity sensor, Background suppression |
Dimensions (W x H x D) | 12.2 mm x 41.8 mm x 17.3 mm |
Housing design (light emission) | Rectangular |
Mounting hole | M3 |
Sensing range max. | 25 mm … 300 mm 1) |
Sensing range | 25 mm … 300 mm 1) |
Type of light | Visible red light |
Light source | Laser 2) |
Light spot size (distance) | Ø 1 mm (170 mm) |
Wave length | 650 nm |
Laser class | 1 (EN 60825-1:2014, IEC 60825-1:2014 / CDRH 21 CFR 1040.10 & 1040.11) |
Adjustment | Cable
Single teach-in button |
Pin 2 configuration | External input, Teach-in input, Sender off input, Detection output, logic output |
Special applications | Detecting small objects |
- 1) Object with 90 % reflectance (referred to standard white, DIN 5033).
- 2) Average service life: 50,000 h at TU = +25 °C.
Mechanics/electronics
Supply voltage | 10 V DC … 30 V DC 1) |
Ripple | < 5 Vpp 2) |
Current consumption | 30 mA 3) |
Switching output | PNP 4) |
Output function | Complementary |
Switching mode | Light/dark switching 4) |
Output current Imax. | ≤ 100 mA |
Response time | ≤ 0.5 ms 5) |
Response time Q/ on Pin 2 | 300 µs … 450 µs 5) 6) |
Switching frequency | 1,000 Hz 7) |
Switching frequency Q / to pin 2 | 1,000 Hz 8) |
Connection type | Male connector M8, 4-pin |
Circuit protection | A 9)
B 10) C 11) |
Protection class | III |
Weight | 100 g |
Housing material | Plastic, Novodur |
Optics material | Plastic, PMMA |
Enclosure rating | IP66
IP67 |
Ambient operating temperature | –10 °C … +50 °C |
Ambient operating temperature extended | –30 °C … +55 °C 12) 13) |
Ambient temperature, storage | –30 °C … +70 °C |
Repeatability Q/ on Pin 2: | 150 µs 6) |
- 1) Limit values when operated in short-circuit protected network: max. 8 A.
- 2) May not exceed or fall below Uv tolerances.
- 3) Without load.
- 4) Q = light switching.
- 5) Signal transit time with resistive load.
- 6) Valid for Q on Pin2, if configured with software.
- 7) With light/dark ratio 1:1.
- 8) With light / dark ratio 1:1, valid for Q on Pin2, if configured with software.
- 9) A = VS connections reverse-polarity protected.
- 10) B = inputs and output reverse-polarity protected.
- 11) C = interference suppression.
- 12) As of Ta = 50 °C, a max. supply voltage Vmax. = 24 V and a max. load current Imax. = 50 mA is permitted.
- 13) Operation below Tu –10 °C is possible if the sensor is already switched on at Tu > –10 °C, then cools down, and the supply voltage is subsequently not switched off. Switching on below Tu –10 °C is not permissible.
Safety-related parameters
MTTFD | 424 years (EN ISO 13849-1) 1) |
- 1) Mode of calculation: Parts-Count-calculation.
Communication interface
Communication interface | IO-Link V1.1 |
Communication Interface detail | COM2 (38,4 kBaud) |
Cycle time | 2.3 ms |
Process data length | 16 Bit |
Process data structure | Bit 0 = switching signal QL1
Bit 1 = switching signal QL2 Bit 2 … 15 = empty |
VendorID | 26 |
DeviceID HEX | 0x800109 |
DeviceID DEC | 8388873 |
Smart Task
Smart Task name | Base logics | ||||||
Logic function | Direct
AND OR WINDOW Hysteresis |
||||||
Timer function | Deactivated
On delay Off delay ON and OFF delay Impulse (one shot) |
||||||
Inverter | Yes | ||||||
Switching frequency | SIO Direct: 1000 Hz 1)
SIO Logic: 600 Hz 2) IOL: 450 Hz 3) |
||||||
Response time | SIO Direct: 300 µs … 450 µs 1)
SIO Logic: 750 µs … 900 µs 2) IOL: 800 µs … 1000 µs 3) |
||||||
Repeatability | SIO Direct: 150 µs 1)
SIO Logic: 150 µs 2) IOL: 400 µs 3) |
||||||
|
- 1) SIO Direct: sensor operation in standard I/O mode without IO-Link communication and without using internal sensor logic or time parameters (set to “direct”/”deactivated”).
- 2) SIO Logic: Sensor operation in standard I/O mode without IO-Link communication. Sensor-internal logic or timing parameters plus Automation Functions used.
- 3) IOL: Sensor operation with full IO-Link communication and usage of logic, timing and Automation Function parameters.