SICK 1052873 WSE4S-3N1330H NPN Through-beam Sensor Set

USD 180.18

WSE4S-3N1330H offers 0–4.5 m through-beam sensing, NPN light switching, a sender test input, 2 m PVC cables and V4A hygiene housings.

SKU SICK-1052873 Category
SICK W4S-3 Inox Hygiene

SICK WSE4S-3N1330H Through-beam Hygiene Sensor Set

BrandSICK
Model IdentifierWSE4S-3N1330H
Official Part Number1052873

Technical Overview

The SICK WSE4S-3N1330H is a through-beam photoelectric sensor set comprising a separate sender and receiver. The aligned heads detect interruption of the direct light path over a specified 0–4.5 m sensing range, with a 0–5 m maximum. A 650 nm red PinPoint LED produces a typical 50 mm spot at 2 m. The receiver provides NPN light switching, response below 0.5 ms under resistive load and 1,000 Hz operation at a 1:1 light/dark ratio. No sensitivity adjustment is provided; the sender test input switches emission off at 0 V. V4A stainless-steel hygiene housings, PMMA screens and 2 m PVC three-wire cables support integration.

Through-beam sender/receiver set with 0–4.5 m sensing, NPN light switching, sender test input and 2 m PVC three-wire cables.

Key Features

  • Through-beam photoelectric sensing with separate sender and receiver
  • 0–4.5 m sensing range; maximum 0–5 m
  • 650 nm red PinPoint LED; typical Ø50 mm spot at 2 m
  • NPN light switching; receiver output ≤100 mA
  • <0.5 ms response with resistive load; 1,000 Hz at 1:1 light/dark ratio
  • No sensitivity adjustment; sender test input TE to 0 V switches emission off
  • 2 m PVC three-wire cables; conductor cross-section 0.14 mm²
  • V4A stainless steel 1.4404/316L housings with PMMA front screens
  • Hygiene design; IP66/IP67/IP68/IP69K
  • 10–30 V DC supply; protection class III

Detect interruption of a direct beam between separate stainless-steel sender and receiver heads for external process control.

Technical Specification Matrix

ParameterValue
Functional principleThrough-beam photoelectric sensor; separate sender and receiver
Sensing range0–4.5 m
Maximum sensing range0–5 m
Set componentsSender 2058456 WS4S-3D1330H; receiver 2058630 WE4S-3N1330H
Light sourceVisible red PinPoint LED
Wavelength650 nm
Light spot sizeTypically Ø50 mm at 2 m
LED service lifeAverage 100,000 h at ambient +25 °C
AdjustmentNone
Digital outputNPN; maximum receiver output current ≤100 mA
Switching modeLight switching
Response time<0.5 ms; resistive load
Switching frequency1,000 Hz at 1:1 light/dark ratio
Sender test inputTE to 0 V switches sender off
Power supply10–30 V DC; short-circuit protected supply network, maximum 8 A
Sender current consumption20 mA; sender only
Residual ripple<5 Vpp; remain within supply limits
Protection classIII
Circuit protectionSupply, inputs and output reverse-polarity protection; interference suppression
Housing designSlim rectangular; Hygiene
Housing materialV4A stainless steel, 1.4404/316L
Front screenPMMA plastic
Connection2 m PVC three-wire cables
Cable assignmentSender: BN=L+, BU=M, BK=Test; receiver: BN=L+, BU=M, BK=Q (CD-061)
Cable handlingDo not bend below 0 °C
IP ratingIP66/IP67/IP68/IP69K
Operating temperature−30 to +60 °C at supply ≤24 V and output current <30 mA
Storage temperature−30 to +75 °C
MTTFD753 years
DCavg0%
Mission time20 years
Cable conductor cross-section0.14 mm²

Industrial Applications

1. Counting separated opaque packs

A conveyor can align the sender and receiver on opposite sides of a path carrying separated opaque packs. Each pack interrupts the direct beam and changes the receiver signal for external counting logic. The installed head spacing stays within the 0–4.5 m sensing range; pack coverage, clear gaps and machine speed are checked against the actual beam geometry and switching requirements.

Problem Solved

Direct-beam interruption gives external counting logic a passage reference for opaque products, helping track conveyor throughput without relying on light reflected from each changing product surface.

Opaque packs Direct beam NPN switching

2. Recognizing an occupied transfer position

A transfer station can align the sender and receiver across a location expected to clear after each load moves onward. A load remaining in the direct beam maintains the interrupted state, which external control evaluates using its own dwell timer. The sensor provides the receiver switching signal; machine control decides when to hold or release the next incoming load.

Problem Solved

Sustained beam interruption supplies external transfer control with an occupancy reference, helping coordinate upstream release when a load remains in place longer than the process expects.

Transfer occupancy External dwell timing Beam interruption

3. Monitoring continuity of an opaque web

A material feeder can place an opaque web between the aligned sender and receiver so normal material blocks the direct beam. A web break exposes the receiver to the sender and changes the switching signal for external feeder control. Installation checks establish sufficient web width, beam coverage and tolerance to flutter while keeping head separation within the specified sensing range.

Problem Solved

A blocked-to-clear beam transition gives external feeder control a possible web-break indication, helping recognize missing material before downstream processing continues without its expected opaque feed.

Opaque web Continuity monitoring Direct beam
Select your currency