Contact Us:
sales@inosaki.com

WS/WE100-2N1439S07 Miniature Photoelectric Sensors – SICK Sensor

$ 128.92

SKU SICK 6052400 Category

SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.

Part Number:6052400
Photoelectric Sensor Model: WS/WE100-2N1439S07
OEM Spec Ref 

Features

Sensor/ detection principle Through-beam photoelectric sensor
Dimensions (W x H x D) 11 mm x 31 mm x 20 mm
Housing design (light emission) Rectangular
Sensing range max. 0 m … 33 m
Sensing range 0 m … 20 m
Type of light Visible red light
Light source LED 1)
Light spot size (distance) Ø 850 mm (12 m)
Wave length 632 nm
Adjustment Potentiometer, 270° (Sensitivity)
  • 1) Average service life: 100,000 h at TU = +25 °C.

Mechanics/electronics

Supply voltage 10 V DC … 30 V DC 1)
Ripple ± 10 % 2)
Power consumption, sender ≤ 15 mA 3)
Power consumption, receiver ≤ 20 mA 3)
Switching output NPN
Switching mode Light/dark switching
Switching mode selector Selectable via light/dark rotary switch
Signal voltage NPN HIGH/LOW Approx. VS / < 1.8 V
Output current Imax. ≤ 100 mA
Response time ≤ 0.5 ms 4)
Switching frequency 1,000 Hz 5)
Connection type Cable, 3-wire, 2 m 6)
Cable material PVC
Conductor cross-section 0.18 mm²
Circuit protection 7)

8)

9)

Protection class III
Housing material Plastic, ABS/PC/POM
Optics material Plastic, PMMA
Enclosure rating IP67
Items supplied 2 Stainless steel mounting brackets (1.4301/304) BEF-W100-A
Ambient operating temperature –25 °C … +55 °C
Ambient temperature, storage –40 °C … +70 °C
  • 1) Limit values.
  • 2) May not exceed or fall below Uv tolerances.
  • 3) Without load.
  • 4) Signal transit time with resistive load.
  • 5) With light/dark ratio 1:1.
  • 6) Do not bend below 0 °C.
  • 7) A = VS connections reverse-polarity protected.
  • 8) B = output reverse-polarity protected.
  • 9) D = outputs overcurrent and short-circuit protected.

Additional information