SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.
Part Number:1067765
Photoelectric Sensor Model:WLG4SC-3P2232A71
OEM Spec Ref
Features
Device type | Photoelectric sensors |
Sensor/ detection principle | Photoelectric retro-reflective sensor, autocollimation |
Dimensions (W x H x D) | 12.2 mm x 41.8 mm x 17.3 mm |
Housing design (light emission) | Rectangular |
Sensing range max. | 0 m … 5 m 1) |
Sensing range | 0 m … 3 m 1) |
Type of light | Visible red light |
Light source | PinPoint LED 2) |
Light spot size (distance) | Ø 45 mm (1.5 m) |
Wave length | 650 nm |
Adjustment | IO-Link
Single teach-in button |
Pin 2 configuration | External input, Teach-in input, Sender off input, Detection output, logic output, Device contamination alarm output |
AutoAdapt | ✔ |
Special applications | Detecting transparent objects |
- 1) Reflector PL80A.
- 2) Average service life: 100,000 h at TU = +25 °C.
Mechanics/electronics
Supply voltage | 10 V DC … 30 V DC 1) |
Ripple | < 5 Vpp 2) |
Current consumption | 20 mA 3) |
Switching output | PNP |
Switching mode | Light/dark switching |
Output current Imax. | ≤ 100 mA |
Response time Q/ on Pin 2 | 300 µs … 450 µs 4) 5) |
Switching frequency | 1,000 Hz |
Switching frequency Q / to pin 2 | 1,000 Hz 6) |
Attenuation along light beam | > 8 % |
Connection type | Male connector M8, 4-pin |
Circuit protection | A 7)
B 8) C 9) D 10) |
Protection class | III |
Weight | 30 g |
Polarisation filter | ✔ |
Housing material | Plastic, ABS |
Optics material | Plastic, PMMA |
Enclosure rating | IP67
IP66 |
Special feature | Detecting transparent objects |
Ambient operating temperature | –40 °C … +60 °C |
Ambient temperature, storage | –40 °C … +75 °C |
UL File No. | NRKH.E181493 & NRKH7.E181493 |
Repeatability Q/ on Pin 2: | 150 µs |
- 1) Limit values when operated in short-circuit protected network: max. 8 A.
- 2) May not exceed or fall below Uv tolerances.
- 3) Without load.
- 4) Signal transit time with resistive load.
- 5) Valid for Q on Pin2, if configured with software.
- 6) With light / dark ratio 1:1, valid for Q on Pin2, if configured with software.
- 7) A = VS connections reverse-polarity protected.
- 8) B = inputs and output reverse-polarity protected.
- 9) C = interference suppression.
- 10) D = outputs overcurrent and short-circuit protected.
Safety-related parameters
MTTFD | 1,222 years |
DCavg | 0 % |
Communication interface
Communication interface | IO-Link V1.1 |
Communication Interface detail | COM2 (38,4 kBaud) |
Cycle time | 2.3 ms |
Process data length | 16 Bit |
Process data structure | Bit 0 = switching signal QL1
Bit 1 = switching signal QL2 Bit 2 … 15 = measuring value |
VendorID | 26 |
DeviceID HEX | 0x8000E0 |
DeviceID DEC | 8388832 |
Smart Task
Smart Task name | Counter + debouncing | ||||||
Logic function | Direct
WINDOW Hysteresis |
||||||
Timer function | Deactivated
On delay Off delay ON and OFF delay Impulse (one shot) |
||||||
Inverter | Yes | ||||||
Response time | 1)
2) |
||||||
Repeatability | 1)
2) |
||||||
Maximum counting frequency | SIO Direct: — 3)
SIO Logic: 1000 µs 1) IOL: 900 µs 2) |
||||||
Counter reset | SIO Direct: —
SIO Logic: 1,5 ms IOL: 1,5 ms |
||||||
Min. Time between two process events (switches) | SIO Direct: —
SIO Logic: 450 µs IOL: 500 µs |
||||||
Debounce time max. | SIO Direct: —
SIO Logic: 30.000 ms IOL: 30.000 ms |
||||||
|
|||||||
Measuring value | Counting value |
- 1) SIO Logic: Sensor operation in standard I/O mode without IO-Link communication. Sensor-internal logic or timing parameters plus Automation Functions used.
- 2) IOL: Sensor operation with full IO-Link communication and usage of logic, timing and Automation Function parameters.
- 3) SIO Direct: sensor operation in standard I/O mode without IO-Link communication and without using internal sensor logic or time parameters (set to “direct”/”deactivated”).
Diagnosis
Status information | |
Device status | Yes |
Quality of teach | Yes |
Quality of run | Yes, Contamination display |