WL4SLC-3P2232A72 Miniature Photoelectric Sensors – SICK Sensor

USD $ 317.52

SKU: SICK 1098509

SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.

Part Number:1098509
Photoelectric Sensor Model:WL4SLC-3P2232A72
OEM Spec Ref 

Features

Sensor/ detection principle Photoelectric retro-reflective sensor, autocollimation
Dimensions (W x H x D) 12.2 mm x 41.8 mm x 17.3 mm
Housing design (light emission) Rectangular
Mounting hole M3
Sensing range max. 0 m … 12 m 1)
Sensing range 0 m … 8 m 1)
Type of light Visible red light
Light source Laser 2)
Light spot size (distance) Ø 1 mm (500 mm)
Wave length 650 nm
Laser class 1 (EN 60825-1:2014, IEC 60825-1:2014 / CDRH 21 CFR 1040.10 & 1040.11)
Adjustment IO-Link

Single teach-in button

Diagnosis Device contamination monitoring, Quality of teach-in
Required accessories Auxiliary sensor (e.g. WL4SL-3P2232, 1061561), Smart-Sensor Y-junction SYL-8204-G0M11-X2 (6055012), 2 x connecting cable (e.g. YF8U14-C60VA3M8U14, 2096612), 2 x reflector (e.g. P250F, 5308843)
  • 1) Reflector PL80A.
  • 2) Average service life: 50,000 h at TU = +25 °C.

Mechanics/electronics

Supply voltage 10 V DC … 30 V DC 1)
Ripple < 5 Vpp 2)
Current consumption 30 mA 3)
Switching output PNP 4)
Output function Complementary
Switching mode Light/dark switching 4)
Output current Imax. ≤ 100 mA
Response time ≤ 0.5 ms 5)
Response time Q/ on Pin 2 300 µs … 450 µs 5) 6)
Switching frequency 1,000 Hz 7)
Switching frequency Q / to pin 2 1,000 Hz 8)
Connection type Male connector M8, 4-pin
Circuit protection 9)

10)

11)

Protection class III
Weight 100 g
Polarisation filter
Housing material Plastic, Novodur
Optics material Plastic, PMMA
Enclosure rating IP66

IP67

Ambient operating temperature –10 °C … +50 °C
Ambient operating temperature extended –30 °C … +55 °C 12) 13)
Ambient temperature, storage –30 °C … +70 °C
UL File No. NRKH.E181493
Repeatability Q/ on Pin 2: 150 µs 6)
  • 1) Limit values when operated in short-circuit protected network: max. 8 A.
  • 2) May not exceed or fall below Uv tolerances.
  • 3) Without load.
  • 4) Q = light switching.
  • 5) Signal transit time with resistive load.
  • 6) Valid for Q \ on Pin2, if configured with software.
  • 7) With light/dark ratio 1:1.
  • 8) With light / dark ratio 1:1, valid for Q \ on Pin2, if configured with software.
  • 9) A = VS connections reverse-polarity protected.
  • 10) B = inputs and output reverse-polarity protected.
  • 11) C = interference suppression.
  • 12) As of Ta = 50 °C, a max. supply voltage Vmax. = 24 V and a max. load current Imax. = 50 mA is permitted.
  • 13) Operation below Tu –10 °C is possible if the sensor is already switched on at Tu > –10 °C, then cools down, and the supply voltage is subsequently not switched off. Switching on below Tu –10 °C is not permissible.

Safety-related parameters

MTTFD 723 years (EN ISO 13849-1) 1)
  • 1) Mode of calculation: Parts-Count-calculation.

Communication interface

Communication interface IO-Link V1.1
Communication Interface detail COM2 (38,4 kBaud)
Cycle time 2.3 ms
Process data length 16 Bit
Process data structure Bit 0 = switching signal QL1

Bit 1 = Detection signal Qint.1

Bit 2 … 15 = measuring value

VendorID 26
DeviceID HEX 0x800222
DeviceID DEC 8389154

Smart Task

Smart Task name Speed and Length Monitoring
Measurement mode Speed

Length

Length incremental

Relative measurement error related to the measured value ≤ 1 %
Resolution measurement value 1 mm / 1 mm/s
Logic function WINDOW
Timer function Impulse width, impulse shift
Max. pulse frequency at the external input (pin 2 / white wire) ≤ 1,000 Hz
Switching signal
Switching signal QL1 Switching output to measuring value switching thresholds
Measuring value Speed measurement value / length measurement value