WL4SLC-3P2232A00 Miniature Photoelectric Sensors – SICK Sensor

USD $ 192.36

SKU: SICK 1080945

SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.

Part Number:1080945
Photoelectric Sensor Model:WL4SLC-3P2232A00
OEM Spec Ref 

Features

Sensor/ detection principle Photoelectric retro-reflective sensor, autocollimation
Dimensions (W x H x D) 12.2 mm x 41.8 mm x 17.3 mm
Housing design (light emission) Rectangular
Mounting hole M3
Sensing range max. 0 m … 12 m 1)
Sensing range 0 m … 8 m 1)
Type of light Visible red light
Light source Laser 2)
Light spot size (distance) Ø 1 mm (500 mm)
Wave length 650 nm
Laser class 1 (EN 60825-1:2014, IEC 60825-1:2014 / CDRH 21 CFR 1040.10 & 1040.11)
Adjustment IO-Link

Single teach-in button

Diagnosis Device contamination monitoring, Quality of teach-in
Pin 2 configuration External input, Teach-in input, Sender off input, Detection output, logic output, Device contamination alarm output
Special applications Detecting small objects
  • 1) Reflector PL80A.
  • 2) Average service life: 50,000 h at TU = +25 °C.

Mechanics/electronics

Supply voltage 10 V DC … 30 V DC 1)
Ripple < 5 Vpp 2)
Current consumption 30 mA 3)
Switching output PNP 4)
Output function Complementary
Switching mode Light/dark switching 4)
Output current Imax. ≤ 100 mA
Response time ≤ 0.5 ms 5)
Response time Q/ on Pin 2 300 µs … 450 µs 5) 6)
Switching frequency 1,000 Hz 7)
Switching frequency Q / to pin 2 1,000 Hz 8)
Connection type Male connector M8, 4-pin
Circuit protection 9)

10)

11)

Protection class III
Weight 100 g
Polarisation filter
Housing material Plastic, Novodur
Optics material Plastic, PMMA
Enclosure rating IP66

IP67

Ambient operating temperature –10 °C … +50 °C
Ambient operating temperature extended –30 °C … +55 °C 12) 13)
Ambient temperature, storage –30 °C … +70 °C
UL File No. NRKH.E181493
Repeatability Q/ on Pin 2: 150 µs 6)
  • 1) Limit values when operated in short-circuit protected network: max. 8 A.
  • 2) May not exceed or fall below Uv tolerances.
  • 3) Without load.
  • 4) Q = light switching.
  • 5) Signal transit time with resistive load.
  • 6) Valid for Q \ on Pin2, if configured with software.
  • 7) With light/dark ratio 1:1.
  • 8) With light / dark ratio 1:1, valid for Q \ on Pin2, if configured with software.
  • 9) A = VS connections reverse-polarity protected.
  • 10) B = inputs and output reverse-polarity protected.
  • 11) C = interference suppression.
  • 12) As of Ta = 50 °C, a max. supply voltage Vmax. = 24 V and a max. load current Imax. = 50 mA is permitted.
  • 13) Operation below Tu –10 °C is possible if the sensor is already switched on at Tu > –10 °C, then cools down, and the supply voltage is subsequently not switched off. Switching on below Tu –10 °C is not permissible.

Safety-related parameters

MTTFD 723 years (EN ISO 13849-1) 1)
  • 1) Mode of calculation: Parts-Count-calculation.

Communication interface

Communication interface IO-Link V1.1
Communication Interface detail COM2 (38,4 kBaud)
Cycle time 2.3 ms
Process data length 16 Bit
Process data structure Bit 0 = switching signal QL1

Bit 1 = switching signal QL2

Bit 2 … 15 = empty

VendorID 26
DeviceID HEX 0x80010F
DeviceID DEC 8388879

Smart Task

Smart Task name Base logics
Logic function Direct

AND

OR

WINDOW

Hysteresis

Timer function Deactivated

On delay

Off delay

ON and OFF delay

Impulse (one shot)

Inverter Yes
Switching frequency SIO Direct: 1000 Hz 1)

SIO Logic: 1000 Hz 2)

IOL: 900 Hz 3)

Response time SIO Direct: 300 µs … 450 µs 1)

SIO Logic: 500 µs … 600 µs 2)

IOL: 500 µs … 900 µs 3)

Repeatability SIO Direct: 150 µs 1)

SIO Logic: 150 µs 2)

IOL: 400 µs 3)

Switching signal
Switching signal QL1 Switching output
Switching signal QL2 Switching output
  • 1) SIO Direct: sensor operation in standard I/O mode without IO-Link communication and without using internal sensor logic or time parameters (set to “direct”/”deactivated”).
  • 2) SIO Logic: Sensor operation in standard I/O mode without IO-Link communication. Sensor-internal logic or timing parameters plus Automation Functions used.
  • 3) IOL: Sensor operation with full IO-Link communication and usage of logic, timing and Automation Function parameters.