WL12L-2B530S05 Small Photoelectric Sensors – SICK Sensor

USD $ 696.57

SKU: SICK 1059521

SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.

Part Number:1059521
Photoelectric Sensor Model:WL12L-2B530S05
OEM Spec Ref 

Features

Sensor/ detection principle Photoelectric retro-reflective sensor, autocollimation
Dimensions (W x H x D) 15 mm x 49 mm x 41.5 mm
Housing design (light emission) Rectangular
Sensing range max. 0 mm … 530 mm 1)
Type of light Visible red light
Light source Laser 2)
Light spot size (distance) Ø 0.5 mm (290 mm)
Wave length 650 nm
Laser class 2 (EN 60825-1:2014, IEC 60825-1:2007) 3)
Adjustment No adjustment possibility
Special applications Detecting small objects, Detection of objects moving at high speeds
  • 1) P41F reflector.
  • 2) Average service life: 50,000 h at TU = +25 °C.
  • 3) Pulse length 4 µs, max. pulse power < 5,0 mW.

Mechanics/electronics

Supply voltage 10 V DC … 30 V DC 1)
Ripple < 5 Vpp 2)
Current consumption 55 mA 3)
Switching output PNP

NPN

Switching mode Light/dark switching
Switching mode selector Selectable via L/D control cable
Signal voltage PNP HIGH/LOW Uv – < 2.9 V, Uv V / 0 V <= 1.5 V
Signal voltage NPN HIGH/LOW Uv – < 2.9 V, Uv V / 0 V <= 1.5 V
Output current Imax. ≤ 100 mA
Response time ≤ 200 µs 4)
Switching frequency 2,500 Hz 5)
Connection type Male connector M12, 5-pin
Circuit protection 6)

7)

8)

Protection class III
Weight 130 g
Polarisation filter
Special device
Housing material Metal
Optics material Plastic, PMMA
Enclosure rating IP67

IP69K

Ambient operating temperature –10 °C … +50 °C
Ambient temperature, storage –25 °C … +75 °C
UL File No. NRKH.E181493 & NRKH7.E181493
  • 1) Limit values when operated in short-circuit protected network: max. 8 A.
  • 2) May not exceed or fall below Uv tolerances.
  • 3) Without load.
  • 4) Signal transit time with resistive load.
  • 5) With light/dark ratio 1:1.
  • 6) A = VS connections reverse-polarity protected.
  • 7) C = interference suppression.
  • 8) D = outputs overcurrent and short-circuit protected.