Contact Us:
sales@inosaki.com

WL12G-3P2582S10 Small Photoelectric Sensors – SICK Sensor

$ 278.08

SKU SICK 1053544 Category

SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.

Part Number:1053544
Photoelectric Sensor Model:WL12G-3P2582S10
OEM Spec Ref 

Features

Device type Photoelectric sensors
Sensor/ detection principle Photoelectric retro-reflective sensor, autocollimation
Dimensions (W x H x D) 15.5 mm x 48.5 mm x 42 mm
Housing design (light emission) Rectangular
Sensing range max. 0 m … 4 m 1)
Type of light Infrared light
Light source LED 2)
Light spot size (distance) Ø 100 mm (3 m)
Wave length 850 nm
Adjustment Single teach-in button 3)
AutoAdapt
Special applications Detecting transparent objects
  • 1) Reflector PL80A.
  • 2) Average service life: 100,000 h at TU = +25 °C.
  • 3) Mode I, 10 % attenuation.

Mechanics/electronics

Supply voltage 10 V DC … 30 V DC 1)
Ripple < 5 Vpp 2)
Current consumption 40 mA 3)
Switching output PNP, with time delay toff 50 ms
Switching mode Light switching
Signal voltage PNP HIGH/LOW Approx. VS – 2.5 V / 0 V
Output current Imax. ≤ 100 mA
Response time ≤ 333 µs 4)
Switching frequency 1,500 Hz 5)
Connection type Male connector M12, 5-pin
Circuit protection 6)

7)

8)

9)

Protection class III
Weight 120 g
Polarisation filter
Special device
Housing material Metal, zinc diecast
Optics material Plastic, PMMA
Enclosure rating IP66

IP67

Special feature Detecting transparent objects
Operating mode Mode I, 10 % attenuation, Mode II, 18 % attenuation
Ambient operating temperature –40 °C … +60 °C
Ambient temperature, storage –40 °C … +75 °C
UL File No. NRKH.E181493 & NRKH7.E181493
  • 1) Limit values when operated in short-circuit protected network: max. 8 A.
  • 2) May not exceed or fall below Uv tolerances.
  • 3) Without load.
  • 4) Signal transit time with resistive load.
  • 5) With light/dark ratio 1:1.
  • 6) A = VS connections reverse-polarity protected.
  • 7) B = inputs and output reverse-polarity protected.
  • 8) C = interference suppression.
  • 9) D = outputs overcurrent and short-circuit protected.

Additional information

Related Products

Festo_Plug Connectors_FBA-2-M12-5POL-RK_533118
camera-ueye-le-usb3
Banner_Q20E_1
Panasonic_SFB-CC3-MU-Panasonic Extension Cable
SICK_sensor_Photoelectric_sensor_V18V_VL18-4N3140V
Omron C200H-OD212
Select your currency