WL12G-3F3072S06 Small Photoelectric Sensors – SICK Sensor
$ 350.90
SKU: SICK 1053543
SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.
Part Number:1053543
Photoelectric Sensor Model:WL12G-3F3072S06
OEM Spec Ref
Features
Device type | Photoelectric sensors |
Sensor/ detection principle | Photoelectric retro-reflective sensor, autocollimation |
Dimensions (W x H x D) | 15.5 mm x 48.5 mm x 42 mm |
Housing design (light emission) | Rectangular |
Sensing range max. | 0 m … 4 m 1) |
Type of light | Visible red light |
Light source | PinPoint LED 2) |
Light spot size (distance) | Ø 25 mm (1.5 m) |
Wave length | 660 nm |
Adjustment | Single teach-in button 3) |
AutoAdapt | ✔ |
Special applications | Detecting transparent objects |
Special features | Mode II inapplicable |
- 1) Reflector PL80A.
- 2) Average service life: 100,000 h at TU = +25 °C.
- 3) Mode I, 10 % attenuation.
Mechanics/electronics
Supply voltage | 10 V DC … 30 V DC 1) |
Ripple | < 5 Vpp 2) |
Current consumption | 40 mA 3) |
Switching output | PNP |
Switching mode | Dark switching |
Output current Imax. | ≤ 100 mA |
Response time | ≤ 333 µs 4) |
Switching frequency | 1,500 Hz 5) |
Connection type | Cable with connector MOLEX MINI-FIT, 3-pin, 250 mm |
Cable material | PVC |
Circuit protection | A 6)
B 7) C 8) D 9) |
Protection class | III |
Weight | 120 g |
Polarisation filter | ✔ |
Special device | ✔ |
Housing material | Metal, zinc diecast |
Optics material | Plastic, PMMA |
Enclosure rating | IP66
IP67 |
Special feature | Detecting transparent objects |
Operating mode | Mode I, 10 % attenuation |
Ambient operating temperature | ≤ +60 °C |
Ambient temperature, storage | –40 °C … +75 °C |
UL File No. | NRKH.E181493 & NRKH7.E181493 |
- 1) Limit values when operated in short-circuit protected network: max. 8 A.
- 2) May not exceed or fall below Uv tolerances.
- 3) Without load.
- 4) Signal transit time with resistive load.
- 5) With light/dark ratio 1:1.
- 6) A = VS connections reverse-polarity protected.
- 7) B = inputs and output reverse-polarity protected.
- 8) C = interference suppression.
- 9) D = outputs overcurrent and short-circuit protected.
Safety-related parameters
MTTFD | 1,099 years |
DCavg | 0 % |