W250-2 – WL250-2P2431 Photoelectric Sensors – Compact Photoelectric Sensors – SICK Sensor

$ 152.46

SKU: N/A

SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.

Part Number: 6044699
Photoelectric Sensor Model: WL250-2P2431
OEM Spec Ref 

Features

Sensor/ detection principle Photoelectric retro-reflective sensor, Dual lens
Dimensions (W x H x D) 20 mm x 65 mm x 43.9 mm
Housing design (light emission) Rectangular
Sensing range max. 0.01 m … 15 m 1)

0.01 m … 12 m 2)

Sensing range 0.01 m … 13 m 1)

0.01 m … 11 m 2)

Type of light Visible red light
Light source LED 3)
Light spot size (distance) Ø 260 mm (8 m)
Angle of dispersion Approx. 2°
Adjustment Potentiometer, 2 turns 4)
  • 1) Reflector PL80A.
  • 2) Reflector P250.
  • 3) Average service life: 100,000 h at TU = +25 °C.
  • 4) With position indicator.

 

Mechanics/electronics

Supply voltage 10 V DC … 30 V DC 1)
Ripple ≤ 5 Vpp 2)
Current consumption 20 mA 3)
Switching output PNP
Switching mode Light/dark switching
Switching mode selector Selectable via L/D control cable
Output current Imax. ≤ 100 mA
Response time ≤ 0.5 ms 4)
Switching frequency 1,000 Hz 5)
Connection type Male connector M12, 4-pin 6)
Circuit protection 7)

8)

9)

10)

Protection class III
Weight + 40 g
Polarisation filter
Housing material Plastic, ABS
Optics material Plastic, PMMA
Enclosure rating IP67
Items supplied Reflector P250, BEF-W250 mounting bracket
EMC EN 60947-5-2 11)
Ambient operating temperature –25 °C … +55 °C
Ambient storage temperature –40 °C … +70 °C
UL File No. NRKH2.E300503 & NRKH8.E300503
  • 1) Limit values when operated in short-circuit protected network: max. 8 A.
  • 2) May not exceed or fall below Uv tolerances.
  • 3) Without load.
  • 4) Signal transit time with resistive load.
  • 5) With light/dark ratio 1:1.
  • 6) Rotatable through 90°.
  • 7) A = VS connections reverse-polarity protected.
  • 8) B = inputs and output reverse-polarity protected.
  • 9) C = interference suppression.
  • 10) D = outputs overcurrent and short-circuit protected.
  • 11) The AC/DC devices comply with the Radio Safety Requirements for the industrial sector (Radio Safety Class A). They may cause radio interference if used in a residential area.