W12-3 – WTB12-3P2431 Photoelectric Sensors – Small Photoelectric Sensors – SICK Sensor
$ 250.58
SKU: N/A
SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.
Part Number:1041411
Photoelectric Sensor Model: WTB12-3P2431
OEM Spec Ref
Features
Sensor/ detection principle | Photoelectric proximity sensor, Background suppression |
Dimensions (W x H x D) | 15.6 mm x 48.5 mm x 42 mm |
Housing design (light emission) | Rectangular |
Sensing range max. | 20 mm … 350 mm 1) |
Sensing range | 20 mm … 350 mm |
Type of light | Visible red light |
Light source | LED 2) |
Light spot size (distance) | Ø 6 mm (200 mm) |
Wave length | 640 nm |
Adjustment | Potentiometer, 5 turns |
- 1) Object with 90 % reflectance (referred to standard white, DIN 5033).
- 2) Average service life: 100,000 h at TU = +25 °C.
Mechanics/electronics
Supply voltage | 10 V DC … 30 V DC 1) |
Ripple | < 5 Vpp 2) |
Current consumption | 45 mA 3) |
Switching output | PNP |
Output function | Complementary |
Switching mode | Light/dark switching |
Signal voltage PNP HIGH/LOW | > Uv – 2,5 V / ca. 0 V |
Output current Imax. | ≤ 100 mA |
Response time | ≤ 330 µs 4) |
Switching frequency | 1,500 Hz 5) |
Connection type | Male connector M12, 4-pin |
Circuit protection | A 6)
C 7) D 8) |
Protection class | III |
Weight | 120 g |
Housing material | Metal |
Optics material | Plastic, PMMA |
Enclosure rating | IP66
IP67 IP69K |
Items supplied | 2 x clamps BEF-KH-W12, incl. screws |
Ambient operating temperature | –40 °C … +60 °C |
Ambient temperature, storage | –40 °C … +75 °C |
UL File No. | NRKH.E181493 & NRKH7.E181493 |
- 1) Limit values when operated in short-circuit protected network: max. 8 A.
- 2) May not exceed or fall below Uv tolerances.
- 3) Without load.
- 4) Signal transit time with resistive load.
- 5) With light/dark ratio 1:1.
- 6) A = VS connections reverse-polarity protected.
- 7) C = interference suppression.
- 8) D = outputs overcurrent and short-circuit protected.
Related products
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details