VS/VE12-2P132 Cylindrical Photoelectric Sensors – SICK Sensor
$ 149.60
SKU: SICK 6026223
SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.
Part Number:6026223
Photoelectric Sensor Model:VS/VE12-2P132
OEM Spec Ref
Features
Sensor/ detection principle | Through-beam photoelectric sensor |
Dimensions (W x H x D) | 12 mm x 12 mm x 55.3 mm |
Housing design (light emission) | Cylindrical |
Housing length | 55.3 mm |
Thread diameter (housing) | Round connector M12 x 1 |
Sensing range max. | 0 m … 5 m |
Sensing range | 0 m … 4 m |
Focus | Approx. 1.4° |
Type of light | Infrared light |
Light source | LED 1) |
Light spot size (distance) | Ø 100 mm (4 m) |
Angle of dispersion | Approx. 1.4° |
Wave length | 880 nm |
Adjustment | None |
- 1) Average service life: 100,000 h at TU = +25 °C.
Mechanics/electronics
Supply voltage | 10 V DC … 30 V DC 1) |
Ripple | ± 10 % 2) |
Current consumption | 20 mA 3) |
Switching output | PNP |
Switching mode | Light/dark switching |
Switching mode selector | Selectable via L/D control cable |
Output current Imax. | ≤ 100 mA 3) |
Response time | ≤ 2 ms 4) |
Switching frequency | 250 Hz 5) |
Connection type | Cable, 4-wire, 2 m 6) |
Cable material | PVC |
Conductor cross-section | 0.14 mm² |
Cable diameter | Ø 3.75 mm |
Circuit protection | A 7)
B 8) C 9) D 10) |
Protection class | III |
Weight | 108 g |
Housing material | Metal, Nickel-plated brass/PA |
Optics material | Plastic, PMMA |
Enclosure rating | IP67 |
Ambient operating temperature | –25 °C … +70 °C |
Ambient temperature, storage | –25 °C … +70 °C |
UL File No. | NMFT2.E175606 |
- 1) Limit values.
- 2) May not exceed or fall below Uv tolerances.
- 3) Without load.
- 4) Signal transit time with resistive load.
- 5) With light/dark ratio 1:1.
- 6) Do not bend below 0 °C.
- 7) A = VS connections reverse-polarity protected.
- 8) B = inputs and output reverse-polarity protected.
- 9) C = interference suppression.
- 10) D = outputs overcurrent and short-circuit protected.