Product Name |
Power supply voltage |
Output capacity |
Options | Model | Standards | ||
---|---|---|---|---|---|---|---|
Total power consumption |
24-VDC service power supply |
RUN output |
Maintenance forecast monitor |
||||
AC Power Supply Unit |
100 to 240 VAC |
90 W | No | Yes | No | NX-PA9001 | UC1, N, L, CE, RCM, KC |
DC Power Supply Unit |
24 VDC | 70 W | NX-PD7001 |
Item | Specifications | |
---|---|---|
Model | NX-PA9001 | NX-PD7001 |
Dimensions | 80 × 100 × 100 mm (W × H × D) |
51 × 100 ×100 mm (W × H × D) |
Weight | 570 g | 290 g |
Power supply voltage | 100 to 240 VAC (wide-range), 50/60 Hz (85 to 264 VAC, 47 to 63 Hz) |
24 VDC (20.4 to 28.8 VDC) |
Power consumption | 150 VA max. | 85 W max. |
Inrush current *1 | At 100 VAC: 20 A *2/8 ms max. for cold start at room temperature At 200 VAC: 40 A *2/8 ms max. for cold start at room temperature |
At 24 VDC: 30 A/2 ms max. for cold start at room temperature 7 A *3/3 s max. for cold start at room temperature |
Output capacity *4 | Total: 90 W max. | Total: 70 W max. |
Output terminal (service supply) |
Not provided. | |
RUN Output | Contact configuration: SPST-NO Switch capacity: 250 VAC, 2 A (resistive load) 120 VAC, 0.5 A (inductive load), 24 VDC, 2A (resistive load) |
|
Replacement notification function |
Not provided. | |
Insulation resistance | 20 MΩ min. (at 500 VDC) between AC external and GR terminals *5 |
— *6 |
Dielectric strength | 2,300 VAC 50/60 Hz for 1 min between AC external and GR terminals *5 *7 Leakage current: 5 mA max. |
— *6 |
*1. The inrush current may vary depending on the operating condition and other conditions. Therefore, select fuses,
breakers, and external power supply devices that have enough margin in characteristic and capacity,
considering the condition under which the devices are used.
*2. If the ambient temperature is higher or the Controller is hot-started, the inrush current given in the table may be
exceeded by up to twice the given value because the thermistor element with a low-temperature current control
characteristic is not sufficiently cool.
*3. Of the inrush current values, the latter value varies depending on the input voltage and may rise to approx. 8.3 A
at 20.4 VDC.
*4. Internal components in the Power Supply Unit will deteriorate or be damaged if the Power Supply Unit is used for an
extended period of time exceeding the power supply output capacity or if the outputs are shorted.
*5. Apply the voltage between the Power Supply Unit’s L1 or L2 terminal and the GR terminal when testing insulation and
dielectric strength. The tests can also be performed with the LG terminal and GR terminal connected to each other.
In this case, the leakage current will be 10 mA or less.
*6. The primary DC power supply and the secondary DC power supply are not isolated.
*7. Change the applied voltage gradually using the adjuster on the Tester. If the full dielectric strength voltage is applied
or turned OFF using the switch on the Tester, the generated impulse voltage may damage the Power Supply Unit.
INOSAKI Limited
RM B 5/F Gaylord Comm,
Bldg 114-118 Lockhart Rd.
Hong Kong
INOSAKI Sdn. Bhd.
2-1-9, Ground Floor, One Square, Tingkat Mahsuri 1,
11900 Bayan Lepas, Penan
INOSAKI Pte. Ltd.
101 Upper Cross Street,
No. 06-17, People’s Park Centre,
Singapore (058357)