GTB10-R3811 – Small Photoelectric Sensors – SICK Sensors

$ 86.24

SKU: SICK 1064686

SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.

Part Number: 1064686
Photoelectric Sensors Model: GTB10-R3811
OEM Spec Ref 

Features

Functional principle Photoelectric proximity sensor
Functional principle detail Background suppression
Dimensions (W x H x D) 20 mm x 50 mm x 51.5 mm
Housing design (light emission) Rectangular
Sensing range max. 20 mm … 950 mm 1)
Type of light Visible red light
Light source PinPoint LED 2)
Light spot size (distance) Ø 8 mm (700 mm)
Wave length 625 nm
Adjustment Potentiometer, 5 turns
  • 1) Object with 90% remission (based on standard white, DIN 5033).
  • 2) Average service life: 100,000 h at TU = +25 °C.

 

Mechanics/electronics

Supply voltage 24 V AC/DC … 240 V AC/DC 1)
Ripple < 5 Vpp 2)
Power consumption ≤ 2.5 VA
Switching output Relay, SPDT, electrically isolated 3)
Switching load max. (current/voltage) 0.11 A (250 V DC)

3 A (30 V DC)

3 A (250 V AC)

Response time ≤ 10 ms
Switching frequency 20 Hz 4)
Connection type Cable, 5-wire, 2 m 5)
Cable material PVC
Conductor cross section 0.25 mm²
Circuit protection 6)
Protection class II 7)
Weight 115 g
Interference emission EN 61000-6-3 (2011-09) 8)
Housing material Plastic, ABS/PMMA
Enclosure rating IP67
Relay switching cycles min. 100.000 cycles (3 A)
Electromagnetic compatibility (EMC) EN 60947-5-2
EN 61000-6-3 (2011-09)
Ambient operating temperature –30 °C … +60 °C 9)
Ambient temperature, storage –40 °C … +70 °C
UL File No. NRKH.E348498 & NRKH7.E348498
More standards UL325 10)
  • 1) +- 10 %.
  • 2) May not exceed or fall below Uv tolerances.
  • 3) Provide suitable spark suppression for inductive or capacitive loads.
  • 4) With light/dark ratio 1:1.
  • 5) Do not bend below 0 °C.
  • 6) C = interference suppression.
  • 7) Reference voltage: 250 V AC.
  • 8) In the case of a DC supply (ref. to EN 61000-6-3) the length of cable between the supply source and the sensor must be < 30 m.
  • 9) UL: 0 °C … +50 °C.
  • 10) Complies with the UL325 standard when used with sturdy protection hood (e.g. BEF-G10WSG, 2071960).
Weight 0.164 kg
Dimensions 8.0 × 7.0 × 13.0 cm