GTB10-P1212- Small Photoelectric Sensors – SICK Sensor
$ 72.82
SKU: SICK 1065856
SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.
Part Number: 1065856
Photoelectric Sensor Model: GTB10-P1212
OEM Spec Ref
Features
Device type | Photoelectric sensors |
Sensor/ detection principle | Photoelectric proximity sensor, Background suppression |
Dimensions (W x H x D) | 20 mm x 50 mm x 39 mm |
Housing design (light emission) | Rectangular |
Sensing range max. | 20 mm … 950 mm 1) |
Type of light | Visible red light |
Light source | PinPoint LED 2) |
Light spot size (distance) | Ø 8 mm (700 mm) |
Wave length | 625 nm |
Adjustment | Potentiometer, 5 turns |
- 1) Object with 90 % reflectance (referred to standard white, DIN 5033).
- 2) Average service life: 100,000 h at TU = +25 °C.
Mechanics/electronics
Supply voltage | 10 V DC … 30 V DC 1) |
Ripple | < 5 Vpp 2) |
Current consumption | 20 mA |
Switching output | PNP |
Switching mode | Light/dark switching |
Switching mode selector | Selectable via light/dark selector |
Output current Imax. | ≤ 100 mA |
Response time | ≤ 500 µs 3) |
Switching frequency | 1,000 Hz 4) |
Connection type | Cable, 3-wire, 2 m 5) |
Cable material | PVC |
Conductor cross-section | 0.14 mm² |
Circuit protection | A 6)
B 7) C 8) D 9) |
Protection class | III |
Weight | 90 g |
Housing material | Plastic, ABS/PMMA |
Enclosure rating | IP67 |
Items supplied | Mounting bracket BEF-G10DC01 |
Electromagnetic compatibility (EMC) | EN 60947-5-2 |
Ambient operating temperature | –30 °C … +60 °C |
Ambient temperature, storage | –40 °C … +70 °C |
UL File No. | NRKH.E348498 & NRKH7.E348498 |
More standards | UL325 10) |
- 1) Limit values when operated in short-circuit protected network: max. 8 A.
- 2) May not exceed or fall below Uv tolerances.
- 3) Signal transit time with resistive load.
- 4) With light/dark ratio 1:1.
- 5) Do not bend below 0 °C.
- 6) A = VS connections reverse-polarity protected.
- 7) B = inputs and output reverse-polarity protected.
- 8) C = interference suppression.
- 9) D = outputs overcurrent and short-circuit protected.
- 10) Complies with the UL325 standard when used with sturdy protection hood (e.g. BEF-G10WSG, 2071960).
Weight | 0.194 kg |
---|---|
Dimensions | 8.0 × 7.0 × 18.0 cm |
Related products
-
Select options This product has multiple variants. The options may be chosen on the product page Details