Contact Us:
sales@inosaki.com

GTB10-P1211 Small Photoelectric Sensors – SICK Sensor

$ 78.76

SKU N/A Category

SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.

Part Number: 1065854
Photoelectric Sensor Model: GTB10-P1211
OEM Spec Ref 

Features

Sensor/ detection principle Photoelectric proximity sensor, Background suppression
Dimensions (W x H x D) 20 mm x 50 mm x 39 mm
Housing design (light emission) Rectangular
Sensing range max. 20 mm … 950 mm 1)
Type of light Visible red light
Light source PinPoint LED 2)
Light spot size (distance) Ø 8 mm (700 mm)
Wave length 625 nm
Adjustment Potentiometer, 5 turns
  • 1) Object with 90 % reflectance (referred to standard white, DIN 5033).
  • 2) Average service life: 100,000 h at TU = +25 °C.

 

Mechanics/electronics

Supply voltage 10 V DC … 30 V DC 1)
Ripple < 5 Vpp 2)
Current consumption 20 mA
Switching output PNP
Switching mode Light/dark switching
Switching mode selector Selectable via light/dark selector
Output current Imax. ≤ 100 mA
Response time ≤ 500 µs 3)
Switching frequency 1,000 Hz 4)
Connection type Cable, 3-wire, 2 m 5)
Cable material PVC
Conductor cross-section 0.14 mm²
Circuit protection 6)

7)

8)

9)

Protection class III
Weight 90 g
Housing material Plastic, ABS/PMMA
Enclosure rating IP67
Electromagnetic compatibility (EMC) EN 60947-5-2
Ambient operating temperature –30 °C … +60 °C
Ambient temperature, storage –40 °C … +70 °C
UL File No. NRKH.E348498 & NRKH7.E348498
More standards UL325 10)
  • 1) Limit values when operated in short-circuit protected network: max. 8 A.
  • 2) May not exceed or fall below Uv tolerances.
  • 3) Signal transit time with resistive load.
  • 4) With light/dark ratio 1:1.
  • 5) Do not bend below 0 °C.
  • 6) A = VS connections reverse-polarity protected.
  • 7) B = inputs and output reverse-polarity protected.
  • 8) C = interference suppression.
  • 9) D = outputs overcurrent and short-circuit protected.
  • 10) Complies with the UL325 standard when used with sturdy protection hood (e.g. BEF-G10WSG, 2071960).

Additional information